mbp TEL 30BS Скачать руководство пользователя страница 2

WARNING

ATTENTION!! Read and understand all instructions carefully

before operating equipment.

INJECTION  HAZARD

This equipment generates very high fluid pressure. Spray

from the gun, leaks or ruptured components can inject fluid

through  your  skin  and  into  your  body  and  cause  extremely

serious bodily injury.

The spray gun should never be handled carelessly, nor

spray directed toward any part of the body. Keeps your hands

and fingers away from spray gun nozzle.

Be sure equipment safely devices are operating properly

before each use.

If any fluid appears to penetrate your skin, get emergency

medical  care  at  once.  Do  not  treat  as  a  simple  cut. Tell  the

doctor exactly what fluid was injected.

FIRE  HAZARD

Static electricity is created by the high velocity flow of

fluid  through  the  pump  and  hose.  If  every  part  of  spray

equipment  is  not  properly  grounded,  sparking  immediately.

Check the entire system for positive grounding.

GROUNDING

Before starting to work the pump must be connected to

ground:

INDEX:

WARNINGS        ............................................................

TYPICAL  INSTALLATION        ....................................

PRESSURE  RELIEF  PROCEDURE        ........................

HOSE  SAFETY              .....................................................

SPRAY  GUN  &  OPERATING  INSTRUCTIONS .......

MAINTENANCE (CLEANING AND FLUSHING)   .....

SPRAY  TIPS

......................................................

PARTS  DRAWING AND  LIST

....................

TROUBLESHOOTING  GUIDE

..........................

TECHNICAL  DATA

.............................................

STANDARD  SPRAY  TIPS

...................................

WARRANTY

......................................................

2

3

3

3

3

3

4

4, 5 & 6

7

7

7

8

2

The pump must be connected to ground with a

ground wire which is supplied with the pump

(4 mm

2

 of section and a clamp).  See connection

on page 6.

SPRAY  GUN:  Obtain  grounding  through

connection to a properly grounded fluid hose and

pump.

OBJECT BEING SPRAYED: Use ground wire

and clamp.

AIR  COMPRESOR:  Follow  air  compressor

manufacturer’s recommendations.

Use  ONLY  METAL  PAILS,  which  are

conductive.  Do  not  place  the  pail  on  a

non-conductive  surface,  such  as  paper  or

cardboard,  which  interrupts  the  grounding

continuity.

1.-

2.-

3.-

4.-

5.

-

Содержание TEL 30BS

Страница 1: ...UCTIONTHATMUST BE READ BEFORE OPERATING THE PUMP INSTRUCTIONS AND PARTS LIST SPRAY EQUIPMENT MBPS L C Anboto 17 Poligono ANSOLETA Phone 34 945 132744 Fax 34 945 134756 01006 VITORIA Alava SPAIN P O BO...

Страница 2: ...e If every part of spray equipment is not properly grounded sparking immediately Check the entire system for positive grounding GROUNDING Before starting to work the pump must be connected to ground I...

Страница 3: ...he gun before the fluid being sprayed can dry in it Engage the gun safety latch Shut off the air to the pump Close the air inlet valve Disengage the gun safety latch Hold a metal part of the gun firmi...

Страница 4: ...lter and clean them with solvent Flush the sprayer at the end of each work day and fill it with solvent to help prevent pump corrosion 4 SPRAYTIPS When a tip is the wrong size or becomes the wrong siz...

Страница 5: ...100 MESH FILTER 200 MESH 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 19 20 21 22 25 26 27 28 29 30 31 32 33 34 G 100 XX C PA1 01 C 200 01X B 120 00X B 130 01X B 130 02 B 130 03X C TU1 01 B 110 00X B 100...

Страница 6: ...TAINER GROUND 1 1 1 2 1 1 1 2 2 1 2 1 1 1 1 1 2 1 6 16 2 2 2 2 4 1 2 2 1 1 N REF DESCRIPCION Q A 110 02 CJT 001 A 210 01 A 120 04 A 220 07 A 120 08 A 221 00 CTJ 002 A 240 02 A 240 01 A 122 00 CJT 005...

Страница 7: ...100 150 200 250 300 350 100 150 200 250 300 350 100 150 200 250 300 350 009 9 20 9 40 9 60 011 11 20 11 40 11 60 013 13 20 13 40 13 60 015 15 20 15 40 15 60 017 17 20 17 40 17 60 019 19 20 19 40 19 60...

Страница 8: ...urer M B P will provide purchaser with reasonable assistance in making such claims The Industry Department of The Basque Goverment states that all electric and pneumatic airless equipment manufacture...

Отзывы: