oper3500.doc
Page 11
23/01/2004
4.6 Changing stapling head positions.
1.
To move the stapling heads to the alternative positions, loosen the stapling head locking levers,
figure 7, several turns and then slide the entire stapling unit to the new position.
2.
When moving the stapling head, hold the bracket and retaining plate end, as side pressure on the
front end of the stapling head will cause misalignment between stapling head and anvil.
3.
Re-tighten the locking levers into the tapered hole, which will align the stapling head in the new
position.
Figure 7 - Stapling head adjustment and anvil positions (centre head not shown).