background image

T10103

Dec 2000

Booklet Feeder Model 46 Operator Manual

1-1

1. Introduction

1.1 Operational safety

Always

 connect the equipment to a properly

grounded power source receptacle. In doubt,
have the receptacle checked by a qualified
electrician.

WARNING: 

Improper connection of the equip-

ment grounding conductor can result in electri-
cal shock.

Always

 follow all warnings marked on, or

supplied with, the equipment.

Always

 locate the equipment on a solid sup-

port surface with adequate strength for the
weight of the machine.

Always

 exercise care in moving or relocating

the equipment.

Always

 keep magnets and all devices with

strong magnetic field away from the machine.

Never

 use a ground adapter plug to connect

the equipment to a power source receptacle
that lacks a ground connection terminal.

Never

 attempt any maintenance function that

is not specifically described in this documenta-
tion.

Never 

remove the covers or guards that are

fastened with screws.

Never

 install the unit near a radiator or any

other heat source.

Never

 override or “cheat” electrical or me-

chanical interlock devices.

Never

 operate the equipment if you notice

unusual noises or odours. Disconnect the
power cord from the power source receptacle
and call your customer service engineer to
correct the problem.

Attention to the following notes ensures the continued safe operation of your equipment.

Содержание Model 46

Страница 1: ...Booklet Feeder Model 46 Operator Manual Dec 2000 Part No 45993...

Страница 2: ...chart 2 2 2 3 How to read the display 2 3 2 4 Explanation of the menus 2 3 3 Operator instructions 3 1 Setting up the Model 46 3 1 3 2 Adjusting the separation 3 2 3 3 Loading 3 3 3 4 Programming the...

Страница 3: ...ys keep magnets and all devices with strong magnetic field away from the machine Never use a ground adapter plug to connect the equipment to a power source receptacle that lacks a ground connection te...

Страница 4: ...in components 1 Insert side guides 2 Insert front guide 3 Separator pads adjustment knob 4 Outfeed sensor 5 Docking plate 6 Insert rear guide adjustment knob 7 Insert rear guide 8 Control panel 9 Inse...

Страница 5: ...SE PAUSE ADJUST On Line Off Line Off Line Stand Alone Sheets Set 1 L 210mm BS 70 Clear Counter 00075 Counter 00100 Remaining 00025 Sheets Set 1 Length 210mm SPH 2800 BS 70 Run Diagnosis STOP 00075 CON...

Страница 6: ...n the Model 46 is switched on The information in the display shows that the Model 46 is ready to start it is in this case on line with the system and the ID number in the system is one See table below...

Страница 7: ...n menu there are three options SETS PER HOUR CLEAR COUNTER and PRESET COUN TER Scroll select option with the arrow buttons and confirm with the OK button SETS PER HOUR Change the number of sets per ho...

Страница 8: ...es or the ESC button to cancel In either case you will be returned to the Option Menu s Decide whether the Model 46 should be on line or off line with the system or function as a stand alone unit This...

Страница 9: ...e it can create interruption Belt speed is how fast each insert will be fed Enter a per centage using the arrow buttons The range is 60 to 100 Default value is 80 If the belt speed is too slow the ins...

Страница 10: ...collator adjust the paper deflector so that the leading edge of the sheets lands between the insert feed belts on the Model 45 document table To exclude the Model 46 from the system just select Off l...

Страница 11: ...ment knob until the feed belts moves when the booklet is pulled back and forth Booklets up to 3 mm thickness Place the booklet between the separator pads and the feed belt as shown in the figure Tight...

Страница 12: ...be shown in the display Move the rear guide to the right to increase the friction Adjusting the rear guide too much to the right may cause the next insert to follow directly after the first one The er...

Страница 13: ...ed to match units attached Confirm by pressing the OK button Select Belt speed and press the OK button Enter a percentage using the arrow buttons The range is 60 to 100 Default value is 80 Confirm by...

Страница 14: ...ing the test the display will show which part that currently is tested After the test you can scroll with the arrow buttons to check that all parts diagnosed passed the test If all parts checked not p...

Страница 15: ...A 2 t s u d h t i w d e t a n i m a t n o c e b y a m r o s n e S 3 n u R r o s n e s d e e f t u o e h t n a e l c k c e h C e h t f I r o s n e s f o s u t a t s y f i r e v o t s i s o n g a i D e...

Страница 16: ...o i t p u r r e t n I 2 s i t a h t t i n u h c i h w y f i t n e d i o t 4 2 n o i t c e s e e S m e l b o r p e h t g n i s u a c e r a t o n s e h c t i w s k c o l r e t n i e h t t a h t k c e h...

Страница 17: ...in 140 x 210 mm Max 310 x 310 mm Paper weight Min 60 gsm Max Speed Up to 3600 sets per hour Max packing thickness 8 mm Misfeed detection Yes Jam detection Yes Height 1020 mm Width 510 mm Depth 480 mm...