FUNK URBAN
USER MANUAL
p.17
0106
INADEQUATE RESPONSE OF THE TORQUE SENSOR. THE TORQUE SENSOR IS FAULTY.
0801
FAILURE OF THE MOTOR ROTATION SENSOR.
0802
FAILURE OF THE PEDAL ROTATION SENSOR.
0804
CONTROL UNIT TEMPERATURE TOO HIGH.
THE TEMPERATURE SENSOR OF THE CONTROL UNIT DETECTED A TEMPERATURE HIGHER THAN THE PERMISSIBLE LIMIT .
0805
ENGINE TEMPERATURE TOO HIGH. THE ENGINE HAS REACHED A TEMPERATURE HIGHER THAN THE PERMISSIBLE LIMIT.
0806
PERIPHERAL CONNECTOR VOLTAGE ISSUES.
0808
ROTOR LOCKED. THE ENGINE DID NOT START DUE TO A MECHANICAL BLOCKAGE OR A PROBLEM WITH THE TRANSMISSION UNIT CABLE .
0809
THE BATTERY VOLTAGE IS HIGHER THAN THE MAXIMUM ALLOWED.
0810
PROBLEMS WITH THE ELECTRIC CURRENT SENSOR.
0811
THE CONTROL UNIT HAS DETECTED AN EXCESS OF ELECTRIC CURRENT.
1101
COMMUNICATION PROBLEMS BETWEEN THE USER INTERFACE AND THE CONTROL UNIT. CHECK THAT THE CABLE IS INTACT AND CONNECTED CORRECTLY.
1102
ONE OF THE BUTTON PANEL KEYS GOT STUCK IN THE PRESSURE POSITION.
3.5.10 Problem solving
PROBLEM
CAUSE/SOLUTION
The display does not turn on
Check the connession and central system
How to handle error codes
Verify the problem based on the error code description
provided in this manual.
ATTENTION-
If the problem persists after these oper-
ations, request support from a service
center.