MB MBMet-500AB Скачать руководство пользователя страница 5

 

  

3.

 

Parts of Solar Irradiation Transducer  

Details of parts shipped along with Solar Irradiation Transducer are provided in table 3.1 
below. 
 

Mark 
in Fig 

Description 

MBMet-

500AB 

(Fig 3.1) 

MBMet-

500BB 

(Fig 3.2) 

MBMet-

500CB 

(Fig 3.3) 

MBMet-

500DB 

(Fig 3.4) 

Transducer  

01 

01 

01 

01 

Temperature sensor 

NA 

Integrated 

PT100 

External 

Ambient 

PT1000 

External 

PV Module 

PT1000 

SS Spring Clip for Temperature 
sensor mount 

NA 

NA 

01 

NA 

Mounting Plate (SS-304) 

01 

01 

01 

01 

M5 X 32mm SS Hex Screw 

02 

02 

02 

02 

M5 SS Washer 

04 

04 

04 

04 

M5 Spring Washer 

04 

04 

04 

04 

M5 SS Nut 

04 

04 

04 

04 

M5 X 20mm SS Round Screw 

02 

02 

02 

02 

 

Table-3.1: Parts shipped with MBMet-500. 

 

    

 

Fig-3.1: MBMet-500AB Parts  

 

Fig-3.2: MBMet-500BB Parts

 

 

 

 

Содержание MBMet-500AB

Страница 1: ...Specifications Solar Irradiation Sensor 3 3 Parts of Solar Irradiation Transducer 5 4 Solar Irradiation Transducer Installation 6 5 Solar Irradiation Sensor Connections 8 6 MBMet 500 Default Configura...

Страница 2: ...l and get acquainted with the senor connections and terminals before commencing installation activity Before connecting the sensor system read its label to confirm power supply requirements All connec...

Страница 3: ...per annum Cell Temperature Range 40 to 900 C Accuracy 0 3 FS Resolution 0 1 Response Time 2 3 seconds Ambient Air Temperature Integrated Sensor Sensor Type RTD PT100 Range 40 to 900 C Accuracy 0 3 FS...

Страница 4: ...or Enclosure Size 120 L x 76 W x 65 H mm Weight 350 grams approx Mounting clamp suitable for mounting on PV module side SS 304 Cable terminals 1 5 sq mm copper Integrated Ambient Temperature Sensor 40...

Страница 5: ...ucer 01 01 01 01 2 Temperature sensor NA Integrated PT100 External Ambient PT1000 External PV Module PT1000 3 SS Spring Clip for Temperature sensor mount NA NA 01 NA 4 Mounting Plate SS 304 01 01 01 0...

Страница 6: ...her location Care must be taken that the sensor inclination is same as PV Module Step 1 Drill two holes M6 at site where the Solar Irradiation sensor is intended to be installed according to the follo...

Страница 7: ...the figure 4 3 Fig 4 3 Holes for fixing sensor to mounting plate Note Keep the sensor cover with solar cell safely Ensure that there is no scratch on the solar cell and it is not soiled Step 4 Connec...

Страница 8: ...V DC 2 GND GND GND GND 3 RS485 D RS485 D RS485 D RS485 D 4 RS485 D RS485 D RS485 D RS485 D 5 NA Integrated Ambient Temperature RTD A External Ambient Temperature RTD A External PV Module Temperature...

Страница 9: ...del Un supported values will be read as 0 Parameters from the sensor can be read via MODBUS protocol in both signed integer and float data formats MODBUS Register Address Parameter Default Values Leng...

Страница 10: ...ion 16 Read only Unsigned Integer 112 Software Version 16 Read only Unsigned Integer 113 Manufacture Year 16 Read only Unsigned Integer 114 Device Serial number 16 Read only Unsigned Integer Table 7 1...

Страница 11: ...ister 105 else the settings will not be saved ii Please note that writing single register is not allowed All the registers are to be written in one MODBUS write command Step 4 After all the parameters...

Страница 12: ...communication parameters is as follows Step 1 Switch Off the power supply of the device Step 2 Locate the Jumper 1 on the PCB as shown in Fig 7 3 1 The normal position of the jumper is shown in Fig 7...

Страница 13: ...the jumper in the original factory position as in Fig 7 3 2 Communication parameters is reset to default settings This will not change any other settings of the device 8 General Maintenance General m...

Отзывы: