AIR CONDITIONING
SG02 - Control System [Manual Air Conditioning]
SG02-5
TC070-15-01H
Blower relay
Blower relay is classified as Type B as shown in
the table below. Its function is to be checked by
measuring the continuities.
Type B relay
*
* It requires supplying battery voltage.
Service Tip
Although your multi-meter might have a function to check continuity by giving beep
sounds, use the range of your multi-meter to check resistance (ohm) when you check
continuity between the terminals B and D. This is because your multi-meter may
determine there is a malfunction due to the combined resistance of the resister and
coil between the terminals B and D.
Blower motor
Service Tip
Blower motor can be inspected by directly supplying battery voltage. Connect battery
positive voltage to blower motor terminal A, connect terminal B to ground, and then
verify its operation. It should be operated the same as Fan switch is at its position 4.
Содержание TC070-15-01H
Страница 12: ...AIR CONDITIONING SG01 Basic System SG01 2 TC070 15 01H A C Components Name the components...
Страница 23: ...AIR CONDITIONING SG01 Basic System SG01 13 TC070 15 01H Review Exercise 1 Name the components...
Страница 55: ...AIR CONDITIONING SG02 Control System Manual Air Conditioning SG02 17 TC070 15 01H Cont d...
Страница 56: ...AIR CONDITIONING SG02 Control System Manual Air Conditioning SG02 18 TC070 15 01H Technical Data...