9

12.  DAILY OPERATION

1

o operate the WAVE 200 XL:

1.   On the MMI, press the POOL button. The robot will start moving towards the pool, while pulling 

the floating cable, and enter it and position itself on the pool floor. Make sure it straightend itself 
vertically to the wall of the starting point and that the angle from the wall is less than 45°.

2.   Wait for the WAVE 200 XL screens to appear. Press Start (i.e. press the two green buttons 

simultaneously). The cleaning session will begin.

3.  To stop the cleaning session at any time, press the right grey button on the MMI console (see the 

button marked 4 in the figure on page 5).

4.   Press the HOME button. The robot will start to move in the direction of the floating cable. Roll the 

floating cable neatly on the cable roller using the cable roller handle. Holding the floating cable, 
gently pull the robot upwards and towards the Caddy. As it reaches the side of the pool, pull the 
cable gently until the floating cable handle emerges. Grasp the handle and pull the robot out of 
the water. The robot will shut down automatically. 

5.   You can use the remote control to drive the WAVE 200 XL to the Caddy. Outside the pool, do not 

pull the robot towards the Caddy by rolling up the floating cable with the cable roller handle.

6.  Clean the filter as needed. When the MMI displays Filter Full, you should clean before the next 

operating cycle. 

 Note:

 It is not necessary to stop the WAVE 200 XL in the middle of the cycle when the Filter Full 

indicator appears. Clean the filter before the next cycle.

7.  Before each operating cycle, clean the robot body, brushes and driving belt area and remove 

foreign objects, rubber bands, hair, etc.

8.  Once a week clean the impeller area:

   

CAUTION

 Make sure the power supply is switched off and unplugged before service.

•  Remove the four screws securing the cover of the impellers using a No. 2 Philips manual 

screwdriver.

•  Open and remove the cover of the impellers.
•  Remove foreign objects from the impellers.
•  Close the cover of the impellers and reassemble the four securing screws.

9.  Make sure the floating cable is not tangled so it can be rolled up easily.

    

Important:

 Every two or three cleaning sessions, disconnect the floating cable from the roller inner 

connection, unroll the entire cable and re-arrange it on the roller as required.

10.  A warning message to perform Preventive Maintenance will appear on the MMI screen, when 

applicable. It is obligatory that Preventive Maintenance service be performed in a timely manner. 
Please contact your dealer. Failure to perform the Preventive Maintenance service will void the 
warranty.

Содержание Dolphin WAVE 200 XL

Страница 1: ...8151457 Rev 02 User Instructions WAVE 200 XL Pool Cleaner by www maytronics com ...

Страница 2: ......

Страница 3: ...ONS AND WATER CONDITIONS 3 4 INTRODUCTION 3 5 CONTENTS 4 6 ASSEMBLY INSTRUCTIONS 4 7 GENERAL NOTES 5 8 MMI ALERTS 5 9 MMI FUNCTIONS 6 10 CHOOSING ADDITIONAL POOL PROFILES 7 11 SETTINGS 7 12 DAILY OPERATION 9 13 REMOTE CONTROL UNIT USAGE 10 14 CLEANING THE FILTER 11 15 TROUBLESHOOTING 11 WAVE 200 XL User Instructions ...

Страница 4: ...e GFCI is defective If the GFCI interrupts power to the power unit without the test button being pushed a ground current may be flowing indicating the possibility of an electric shock Do not use the power unit Disconnect the power unit and contact the manufacturer for assistance WARNING To reduce the risk of electric shock replace damaged cord immedietely Do not use extension cord to connect unit t...

Страница 5: ...P 68 Minimum depth 0 40 m 1 3 ft Maximum depth 7 m 22 96 ft 4 INTRODUCTION This user guide describes how to operate your WAVE 200 XL and how to use your MMI console The interactive state of the art MMI Maytronics Machine Interactive control console enables full control of the robot and allows you to determine the cycle time operation delay and cleaning scan that the robot performs It also enables ...

Страница 6: ...dy handle to the Caddy base and fasten with the four screws and four nuts provided 2 Attach the cable roller in its designated place and fasten with two screws Note that the connection cable is located between the power supply and cable roller 3 Connect the MMI communications cable to the power supply unit 4 Connect the connection cable between the power supply and the cable roller Roller inner co...

Страница 7: ...0 XL has the following alert LEDs FILTER CHAMBER This LED lights up when the filter is full and needs to be cleaned at the end of the cleaning cycle If this LED lights up mid cycle you do not need to immediately stop the operation and can wait until the cycle is completed This LED indicator will automatically reset when the robot starts a new cycle with a clean filter ALERT This LED lights up to ind...

Страница 8: ...owntothesecondMain Menu screen Figure3 Main Menu Parameters T T T Parameter Description Pool Profile PressSelect toaccessthePool Profile scr 0 0Tofilescreendisplays thefourdifferentconfiguredPoolProfiles Note The WAVE 200 XL comes with a default pool profile parameter To change the pool profile parameter reference Figure 6 Filter State Reports on the filter s condition Clean Filter is ready for us...

Страница 9: ... displayed as the currently defined setting as shown in Figure 4 2 Press Pool A to access the Pool Profile screen The Pool Profile screen is displayed Figure 5 3 Choose one of the additional pool profiles Pool B Pool C or Pool D and press Select The Wave screen is automatically displayed with the selected pool profile 11 SETTINGS The WAVE 200 XL is controlled from the MMI console Four different swimm...

Страница 10: ...nes to left Lines to right Pool A profile menu Select Back Pool A profile menu Select Back Pool length 25m Cycle time 4h Pool type Rect Scanning Crisscross R Display time No Line spacing Medium Reset pool A profile Pool length setup Meters Ft 15 20 25 30 35 Set Back Set Back Rectangular Shaped Pool type Set Back Pool with obstacles Lines to left Lines to right Set Back Scanning mode Crisscross Line...

Страница 11: ...owards the Caddy by rolling up the floating cable with the cable roller handle 6 Clean the filter as needed When the MMI displays Filter Full you should clean before the next operating cycle Note It is not necessary to stop the WAVE 200 XL in the middle of the cycle when the Filter Full indicator appears Clean the filter before the next cycle 7 Before each operating cycle clean the robot body brushe...

Страница 12: ...tart the automatic operations of the WAVE 200 XL 2 Press the On Off button to activate the remote control 3 Press the Forward or Backward buttons to maneuver the WAVE 200 XL forwards or backwards at a faster speed 4 Press the Forward or Backward buttons again to maneuver the WAVE 200 XL forwards or backwards at the standard cleaning speed 5 To stop the WAVE 200 XL press the button showing the oppo...

Страница 13: ...om the main Wave screen press on the green buttons in sequence right left right left and follow the instructions displayed on the screen Error Message Possible Cause Action Imp overload Is there dirt or other foreign matter in the impeller Disconnect the robot from the mains electricity remove the screws and remove the impeller cover Remove any dirt from around the impeller Reassemble the impeller...

Страница 14: ...Maytronics dealer Robot is stuck Is the robot stuck on an obstacle Is there an obstruction in the water channel or in the robot s driving belts Move the robot from its position and remove the obstacle Reactivate If this reoccurs contact your Maytronics dealer Navigation System Does the problem reoccur with every operation Contact your Maytronics dealer No Communication Does the problem occur when ...

Страница 15: ......

Страница 16: ...8151457 Rev 02 WAVE 200 XL Pool Cleaner by www maytronics com ...

Отзывы: