Electrical Service Information

Electrical Dryers

• 240 VAC, 60 Hz, 30 Amps,

3–wire or 4–wire installations

Gas Dryers

• 120 VAC, 60 Hz, 15 Amps, 3–wire installations

About Ground Wires

In the event of an electrical short circuit, a ground wire
reduces the risk of electric shock by providing an escape
wire for the electric current.
Standard accepted color coding for ground wires is 

green

or 

green with a yellow stripe.

Grounding wires and wires colored like grounding wires
are 

NOT

 to be used as current carrying conductors.

WARNING

!

To reduce the risk of fire, electric shock, serious injury
or death, all wiring and grounding must conform with
the latest edition of the National Electric Code, or the
Canadian Electrical Code, and such local regulations
as might apply. It is the customer’s responsibility to
have the wiring and fuses checked by a qualified
electrician to make sure your home has adequate
electrical power to operate the dryer.

WARNING

!

To avoid risk of personal injury or death due to
electrical shock:

Observe all local codes and ordinances.

• Disconnect electrical power to unit before servicing.
• Ground appliance properly.
• Check with a qualified electrician if you are not sure

this appliance is properly grounded.

• DO NOT ground to gas line.
• DO NOT ground to cold water pipe if pipe is

interrupted by plastic, nonmetallic gaskets, or other
insulating (nonconducting) materials.

• DO NOT modify plug on power cord. If plug does not

fit electrical outlet, have proper outlet installed
by qualified electrician.

• DO NOT have a fuse in the neutral or ground circuit.

A fuse in the neutral or ground circuit could result in
an electrical shock.

• DO NOT use an extension cord with this appliance.
• DO NOT use an adapter plug with this appliance.
• DO NOT pinch power cord.

WARNING

!

To reduce the risk of fire and exposure to combustion
gases, the dryer MUST be exhausted to the outdoors.
DO NOT exhaust dryer air into a window well, gas vent,
chimney or enclosed, unventilated area, such as an
attic, wall, ceiling, crawl space under a building or
concealed space of a building.

Important Safety Information

Gas Dryer Power Supply

This equipment MUST be grounded. In the event of an
electrical short circuit, grounding reduces the risk of
electric shock by providing an escape wire for the
electrical current. This unit is equipped with a cord
having a grounding wire with a grounding plug. The plug
must be plugged into an outlet that is properly installed
and grounded.

Consult a qualified electrician or servicer if grounding
instructions are not completely understood, or if doubt
exists as to whether the equipment is properly grounded.

Do not use an extension cord.  If  the product power cord
is too short, have a qualified electrician install a three–
slot receptacle. This unit should be plugged into a
separate 60 hertz circuit with the electrical rating as
shown on the serial plate.

Proper Grounding and Polarization for 120 Volts
Wall Outlets

For the safety of our customers and the service techni-
cian ALL  gas dryers have a three–prong power cord and
MUST be connected to a properly polarized and grounded
wall outlet. This information was written for those who do
not understand grounding and polarization of a wall
outlet. A 120 VAC wall outlet must always be wired as
shown below.

L1

V.A.C.

115–12 

V.A.C.

115–12 

V.A.C.

Neutral
  side

   Round
grounding
   prong

Ground

Neutral

Explanation

Polarization

–This means that the larger slot must be

neutral and the small slot must be hot (live).

Mispolarized

–The outlet is miswired so that the larger

slot is hot (live) and the smaller slot is neutral.

Grounded

–This means the round hole connection is

connected to ground through a connection to the main
power panel.

Ungrounded

–The round hole connection is not

connected to a ground and/or the main power panel.

Содержание NDE2335AY Series

Страница 1: ...6AW MDG508DAW MDG5806AW MDGT236AW MDGT336AW MDGT446AW NDE2335AY NDE2335AZ NDE5805AY NDE5805AZ NDE8805AY NDE8805AZ NDG2335AW NDG5805AW NDG8805AW PDET910AY PDET910AZ PDET920AY PDET920AZ PDGT910AW PDGT92...

Страница 2: ...OPRIATE SERVICE INFORMATION BEFORE BEGINNING REPAIRS WARNING To avoid risk of severe personal injury or death disconnect power before working servicing on appliance to avoid electrical shock To locate...

Страница 3: ...assembly Procedures Control ConsoleAccess Facia Removal 16 PC Board Removal 16 Cycle Selector Knob Removal 17 Switch Removal 17 Top Cover Door Switch Front Panel Gasket Removal 17 Door Reversal Disass...

Страница 4: ...OPRIATE SERVICE INFORMATION BEFORE BEGINNING REPAIRS WARNING To avoid risk of severe personal injury or death disconnect power before working servicing on appliance to avoid electrical shock To locate...

Страница 5: ...assembly Procedures Control ConsoleAccess Facia Removal 16 PC Board Removal 16 Cycle Selector Knob Removal 17 Switch Removal 17 Top Cover Door Switch Front Panel Gasket Removal 17 Door Reversal Disass...

Страница 6: ...mmable chemicals thinner etc or anything containing wax or chemicals such as mops and cleaning cloths Flammable substances may cause fabric to catch fire by itself 5 Do not store or use gasoline or ot...

Страница 7: ...wer cord WARNING To reduce the risk of fire and exposure to combustion gases the dryer MUST be exhausted to the outdoors DO NOT exhaust dryer air into a window well gas vent chimney or enclosed unvent...

Страница 8: ...al switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire de...

Страница 9: ...2006 Maytag Services 16026315 7 Important Safety Information...

Страница 10: ...anty service is required To locate an authorized servicer For Maytag product call 1 800 462 9824 or visit the Web Site at www maytag com For product in Canada call 1 866 587 2002 or visit the Web Site...

Страница 11: ...2006 Maytag Services 16026315 9 General Information Troubleshooting Guide is located inside the Control Console see Control Console Access Facia Removal Procedure...

Страница 12: ...re harness or object caught in blower wheel area Scraping Check for front or rear bulkhead felt seal out of position or worn tumbler front bearings Roaring Check for blower wheel rubbing on blower hou...

Страница 13: ...d press knob Power Off LED will blink Regular LED will be illuminated Model I D is displayed by the LED s around the bottom of the dial Model I D can be redisplayed while in Service Mode by setting kn...

Страница 14: ...r each switch position NOTE Any attempt to move a knob or switch other than the one being tested results in a chirp sound Press the Cycle Selection Knob The test continues with the switch immediately...

Страница 15: ...nown Default used 31 Rotary Switch 3 left of encoder failed at startup 28 Incorrect rotary switch position seen 24 Dryness sensor bar possibly shorted 23 Dryness sensor bar possibly open 22 Selected d...

Страница 16: ...inals Infinity Less than 1 ohm Light Unplug connectors and test switch terminals Check across terminals 80 to 100 ohms Motor Unplug harness connector and test motor circuits Pin 9 GY and Pin 9 Red Win...

Страница 17: ...from wire insertion side Short sensor bar Pin 3 BU to Pin 7 BU of PS5 Less than 1 ohm Radiant Sensor Unplug connectors and test sensor terminals Closed TH2 Safety Thermostat Unplug connectors and tes...

Страница 18: ...rd to access the wiring harness and PC Board NOTE Wear an Anti Static Wrist Strap and ground yourself before working with Electronic Control Boards Always handle boards by the edge and don t touch dis...

Страница 19: ...e PC Board 4 Lift locking tab on CSK and rotate switch to remove Switch Removal 1 Disconnect power supply to unit 2 Access Control Console see Control Console Access Facia Removal procedure 3 Remove r...

Страница 20: ...procedure Disassembly Procedures WARNING 5 Remove two screws 1 each side from the back flange of the Front Panel 6 Tip Front Panel back and remove Rotate Front Panel to the back side and remove gaske...

Страница 21: ...Panel Rotate Door Panel 180 degrees and move Door Strike to opposite side of Door Reinstall screws Reinstall Door Continue to next step for complete Door disassembly 5 After Door Panel screws are rem...

Страница 22: ...ssembly Procedures WARNING Motor Blower Thermistor Thermostat Removal 1 Disconnect power supply to unit 2 RemoveTop Cover 3 Remove Front Panel 4 Disconnect wiring from Moisture Sensor 5 Remove three s...

Страница 23: ...y Procedures WARNING 8 Remove Blower Cover Panel 9 Disconnect Motor Harness connector from Motor 10 Rotate BlowerAssembly as shown to remove from dryer 11 Remove Blower Wheel by placing a wrench on th...

Страница 24: ...r supply to unit 2 Remove Top Cover and Front Panel see Top Cover Door Switch Front Panel Gasket Removal procedure 3 Remove wires from light see Light Removal procedure steps 3 4 4 Remove four screws...

Страница 25: ...ly to unit 2 Remove Top Cover see Top Cover Door Switch Front Panel Gasket Removal procedure 3 Remove two screws retaining Drum Baffle Heater Removal 1 Disconnect power supply to unit 2 Remove Top Cov...

Страница 26: ...3 Remove Console 4 Remove Front Panel 5 Loosen the single screw attaching the igniter to the Burner Assembly Slide the Igniter back and remove Burner Removal 1 Disconnect power supply to unit 2 Shut o...

Страница 27: ...2006 Maytag Services 16026315 A 1 AppendixA...

Страница 28: ...A 2 16026315 2006 Maytag Services NOTES...

Страница 29: ...ide Optional Kits Kits are available at extra cost through your Maytag dealer or Maytag Customer Assistance at 1 800 688 9900 USA 1 800 688 2002 Canada 1 800 688 2080 TTY USA Only Directional Exhaust...

Страница 30: ...ed To exhaust dryer through sides or bottom install a DK1 Sales Accessory Directional Exhaust Kit 528P3 Available as optional equip ment at extra cost Exhaust System Materials Exhaust duct must be fou...

Страница 31: ...Neutral terminal 4 wire Plug Only Remove ground screw and detach ground wire from bulkhead Attach power cord ground green wire to rear bulkhead using ground screw Attach free ground wire previously at...

Страница 32: ...CSA C22 1 and such local regulations as might apply It is the customer s responsibility to have the wiring and fuses checked by a qualified electrician to make sure your home has adequate electrical...

Страница 33: ...mi rigid duct and exhaust the dryer to the outside by the shortest route possible Failure to exhaust dryer properly will void warranty Dryer exhaust duct must be secured to the mobile home structure D...

Страница 34: ...19 6 cm 4 0 10 2 cm 4 0 10 2 cm 28 71 1 cm 4 1 1 cm 15 4 39 1 cm 26 9 68 3 cm 36 91 4 cm 43 109 2 cm FRONT VIEW w o Closet Door SIDE VIEW FRONT VIEW Closet Door Centered air openings minimum 40 sq in...

Страница 35: ...s Kits are available at extra cost through your Maytag dealer or Maytag Customer Assistance at 1 800 688 9900 USA 1 800 688 2002 Canada 1 800 688 2080 TTY USA Only Directional Exhaust Kit DK1 Sales Ac...

Страница 36: ...ready for rear exhaust No kits required To exhaust dryer through sides or bottom install a DK1 Sales Accessory Directional Exhaust Kit 528P3 Available as optional equip ment at extra cost Exhaust Syst...

Страница 37: ...connected to type of gas as shown on nameplate located in the door recess For proper operation at altitudes above 2 500 feet The natural gas valve spud orifice size must be reduced to ensure complete...

Страница 38: ...nity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas sup...

Страница 39: ...d from the gas supply piping system by closing the equipment shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 45 kPa When co...

Страница 40: ...View of burner with front access panel removed WARNING To prevent personal injury or property damage front panel must be in place during normal operation Close the loading door start the dryer in a h...

Страница 41: ...are information provided in this service manual is representative of a limited number of models Reference the customer s Use and Care literature included with the product order a copy or consult the m...

Страница 42: ...B 2 16026315 2006 Maytag Services...

Страница 43: ...ctions 1 2 Using the Controls Auto Dry Models 3 4 Sensor Models 5 6 Electronic Controls 7 9 Operating Tips 10 Accessories 10 Care Cleaning 11 Reversing the Door 12 Dryer Exhaust Tips 13 Troubleshootin...

Страница 44: ...B 4 16026315 2006 Maytag Services 1...

Страница 45: ...2006 Maytag Services 16026315 B 5 2...

Страница 46: ...B 6 16026315 2006 Maytag Services 3...

Страница 47: ...2006 Maytag Services 16026315 B 7 4...

Страница 48: ...B 8 16026315 2006 Maytag Services 5...

Страница 49: ...2006 Maytag Services 16026315 B 9 6...

Страница 50: ...B 10 16026315 2006 Maytag Services 7...

Страница 51: ...2006 Maytag Services 16026315 B 11 8...

Страница 52: ...B 12 16026315 2006 Maytag Services 9...

Страница 53: ...2006 Maytag Services 16026315 B 13 10...

Страница 54: ...B 14 16026315 2006 Maytag Services 11...

Страница 55: ...2006 Maytag Services 16026315 B 15 12...

Страница 56: ...B 16 16026315 2006 Maytag Services 13...

Страница 57: ...2006 Maytag Services 16026315 B 17 14...

Страница 58: ...B 18 16026315 2006 Maytag Services...

Страница 59: ...om Litho U S A 2005 Maytag Appliances Sales Co Dryer Use Care Guide Important Safety Instructions 1 2 Using the Controls Auto Dry Models 3 4 Electronic Controls 5 7 Operating Tips 8 Accessories 8 Care...

Страница 60: ...B 20 16026315 2006 Maytag Services 1...

Страница 61: ...2006 Maytag Services 16026315 B 21 2...

Страница 62: ...B 22 16026315 2006 Maytag Services 3...

Страница 63: ...2006 Maytag Services 16026315 B 23 4...

Страница 64: ...B 24 16026315 2006 Maytag Services 5...

Страница 65: ...2006 Maytag Services 16026315 B 25 6...

Страница 66: ...B 26 16026315 2006 Maytag Services 7...

Страница 67: ...2006 Maytag Services 16026315 B 27 8...

Страница 68: ...B 28 16026315 2006 Maytag Services 9...

Страница 69: ...2006 Maytag Services 16026315 B 29 10...

Страница 70: ...B 30 16026315 2006 Maytag Services 11...

Страница 71: ...2006 Maytag Services 16026315 B 31 12...

Страница 72: ...B 32 16026315 2006 Maytag Services...

Страница 73: ...Contents Important Safety Instructions 1 2 Using the Controls 5 Cycles Model 3 4 6 Cycles Model 5 6 Operating Tips 7 Accessories 7 Care Cleaning 8 Reversing the Door 9 Dryer Exhaust Tips 10 Troublesh...

Страница 74: ...B 34 16026315 2006 Maytag Services 1...

Страница 75: ...2006 Maytag Services 16026315 B 35 2...

Страница 76: ...B 36 16026315 2006 Maytag Services 3...

Страница 77: ...2006 Maytag Services 16026315 B 37 4...

Страница 78: ...B 38 16026315 2006 Maytag Services 5...

Страница 79: ...2006 Maytag Services 16026315 B 39 6...

Страница 80: ...B 40 16026315 2006 Maytag Services 7...

Страница 81: ...2006 Maytag Services 16026315 B 41 8...

Страница 82: ...B 42 16026315 2006 Maytag Services 9...

Страница 83: ...2006 Maytag Services 16026315 B 43 10...

Страница 84: ...B 44 16026315 2006 Maytag Services 11...

Отзывы: