CAUTIONS
• Be sure to check microwave leakage prior to
servicing the oven if the oven is operative prior to
servicing.
• The service personnel should inform the
manufacture importer, or assembler of any certified
oven unit found to have a microwave emission level
in excess of 5 mW/cm
2
and should repair any unit
found to have excessive emission levels at no cost to
the owner and should ascertain the cause of the
excessive leakage. The service personnel should
instruct the owner not to use the unit until the oven has
been brought into compliance.
• If the oven operates with the door open, the service
personnel should:
- Tell the user not to operate the oven.
• The service personnel should check all surface and
vent openings for microwave leakage.
• Check for microwave leakage after every servicing. The
power density of the microwave radiation leakage
emitted by the microwave oven should not exceed
4 mW/cm
2
. Always start measuring of an unknown field
to assure safety for operating personnel from radiation
leakage.
EQUIPMENT
•
TESTER (VOLTS-DC, AC, Ohmmeter)
• Microwave survey meter
- Holaday HI-1500
HI-1501
- Narda
8100
8200
• 600 cc non conductive material beaker (glass or
plastic), inside diameter: approx. 8.5 cm (3
1
/
2
in.)
• Glass thermometer: 100°C or 212°F (1 deg scale)
MEASURING MICROWAVE ENERGY
LEAKAGE
• Pour 275±15cc of 20±5°C(68±9°F) water in a beaker
which is graduated to 600 cc, and place the beaker
on the center of the turntable.
• Set the energy leakage monitor to 2,450 MHz and
use it following the manufacturer's recommended
test procedure to assure correct result.
• When measuring the leakage, always use the 2-inch
(5cm) spacer supplied with the probe.
• Operate the oven at its maximum output.
• Measure the microwave radiation using and
electromagnetic radiation monitor by holding the
probe perpendicular to the surface being measured.
Move probe along shaded area.
Probe scanning speed
Less than 2.5 cm/sec. ( 1 in/sec)
7-2
MICROWAVE LEAKAGE TEST
Содержание MMV6178AAB
Страница 7: ...4 1 OPERATING INSTRUCTIONS CONTROL PANEL For Model MMV6178AAB MMV6178AAQ MMV6178AAS MMV6178AAW...
Страница 11: ...5 3 MATRIX CIRCUIT FOR TOUCH KEY BOARD For Model MMV6178AAB MMV6178AAQ MMV6178AAS MMV6178AAW...
Страница 37: ...7 25 PROBLEM F No buzzing when touching the key between stages or at end of cooking 1...
Страница 38: ...7 26 PROBLEM G Ventilation fan does not operate when FAN HIGH LOW key is touched 1 Check 1 POWER SUPPLY 2 FUSE...
Страница 43: ...8 5 EV 4001 4000 4002 W111 4003 4002 4004 LATCH BOARD PARTS...
Страница 47: ...8 9 EV VINYL BAG 6011 6009 6010 6008 INSTALLATION PARTS...
Страница 48: ...Printed in Korea P NO 3828W5S4605...