Содержание MMV4203DB - 2.0 cu. Ft. Combination Range Hood-Microwave

Страница 1: ...are Upper Cabinet 8 Installthe Microwave Oven 8 Complete Installation 9 VENTING DESIGN SPECIFICATIONS 10 ASSISTANCE 11 Replacement Parts 11 Accessories 11 MICROWAVE HOOD COMBINATION SAFETY Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symb...

Страница 2: ...ing See Venting Design Specifications section Check the opening where the microwave oven will be installed The location must provide Minimum installation dimensions See Installation Dimensions illustration Minimum one 2 x 4 50 8 x 101 6 mm wood wall stud and minimum 3 8 9 5 mm thickness drywall or plaster lath within cabinet opening Support for weight of 150 Ibs 68 kg which includes microwave oven...

Страница 3: ...d A time delay fuse or time delay circuit breaker A separate circuit serving only this microwave oven GROUNDING iNSTRUCTiONS For all cord connected appliances The microwave oven must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current The microwave oven is equipped with a cord having a grounding w...

Страница 4: ... section if you are using recirculation installation Keep the damper assembly in case the venting method is changed or the microwave oven is reinstalled in another location where wall or roof venting may be used Wall Venting Installation Only 1 Remove damper plate screw and top blower motor screw attaching damper plate to top of microwave oven exterior Lift up damper plate C INSTRUCTIONS 2 Remove ...

Страница 5: ...ower motor face back of microwave oven Lower blower motor back into microwave oven 4 Close damper plate and secure it with screw removed in Step 1 of Wall Venting Installation Only A i B A Damper plate screw B Damper plate C Blower motor screw 5 Reinsert blower motor screw removed in Step 2 of Wall Venting Installation Only 6 Attach damper assembly to damper plate by sliding it into the guides on ...

Страница 6: ... i i i C i NOTE Holes are for installation with 2 lag screws into the wall studs A Cabinet opening vertical centerllne B Holes for toggle bolts C Wall stud centerlines D Holes for lag screws E Support tabs F Mounting plate center marker Ma_ Rea_ The microwave oven must be installed on a minimum of 1 wall stud preferably 2 using a minimum of 1 lag screw preferably 2 1 Using measuring tape find and ...

Страница 7: ...d on at least 1 wall stud the mounting plate must attach to the wall through mounting holes on both ends If the mounting holes are not over wall studs use two 3 16 20 x 3 hex head bolts with toggle nuts If 1 hole is over a wall stud use 1 lag screw and one 3 16 20 x 3 hex head bolt with toggle nut If both end mounting holes are over wall studs use 2 lag screws 1 Drill 5 8 16 mm hole s through the ...

Страница 8: ...sult in back or other injury IMPORTANT The control side of the microwave oven is the heavy side Handle the microwave oven gently 1 Place the 1 4 28 x 3V4 flat head bolts inside upper cabinet near the 1 2 13 mm holes 2 Make sure the microwave oven door is closed and taped shut 3 Using 2 or more people lift microwave oven and hang it on support tabs at the bottom of mounting plate NOTE To avoid dama...

Страница 9: ...n A B For Roof Venting Installation Only 11 Connect vent to damper assembly A B 1 R A Vent B Damper assembly under vent Install filters Refer to the User Instructions for filter placement Electrical Shock Hazard Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrica...

Страница 10: ...compound to seal exterior wall or roof opening around cap not installing 2 elbows together for optimal hood performance If venting through the wall be sure that there is proper clearance within the wall for the damper to open fully If venting through the roof and rectangular to round transition is used be sure there is at least 3 7 6 cm of clearance between the top of the microwave oven and the tr...

Страница 11: ...amper assembly and rectangular to round transition piece must be installed to keep the damper from sticking ASSISTANCE Call your authorized dealer or service center When you call you will need the microwave oven model number and serial number Both numbers can be found on the model and serial number plate which is located behind the microwave oven door on the front frame of the microwave oven If yo...

Страница 12: ...W10188238A SP PN W10188947A 2008 All rights reserved DE68 03534A 9 08 Printed in Malaysia ...