background image

42

16022904 Rev. 0

©2004 Maytag Appliances Company

WARNING

!

To avoid risk of electrical shock, personal injury or death;
disconnect power to unit before servicing.

Disassembly Procedures

Locking
Tabs

Felt
Seal

Note:

When reinstalling, the seal will be mounted to

the tumbler front in a counterclockwise rotation.
Start at the 3:00 position and place under the
locking tabs.  The seal will overlap 1 1/4".  The
coated side (which is the lighter of the two
colors) goes against the tumbler.  The felt seal is
then looped in a "U-shape” so that the lighter-
colored side is against the tumbler front as it is
slid in place under the tabs.  Bend tabs back
over the felt seal with a flat blade screwdriver.

Belt

1. Disconnect power supply to unit.
2. Remove Shroud Assembly.
3. Insert left hand along side of tumbler at the 8 o'clock

position.  Insert right arm under tumbler (as close to
blower as possible).

View From the Back of the Dryer

Idler
Pulley

Motor
Pulley

Drive
Belt

Idler
Spring

Idler Arm

Lint Filter

Note:

Lint Filter is one piece and can be removed for

cleaning.

Bearing & Pads

1. Disconnect power supply to unit.
2. Remove Front  Shroud  Assembly.
3. Drill out the old rivets and rivet new bearings in place.

Note:

In positioning the bearing and cork pad, the face

of the bearing should ride against the tumbler.

Front Seal

1. Disconnect power supply to unit.
2. Remove Front Shroud  Assembly.
3. Remove old felt seal by prying the locking tabs up with

a flat-blade screwdriver.

Note:

Pay close attention to the location of the seal

overlap.  This will be important as you reinstall
the new seal.

Teflon Bearings

on Cork Pads

Felt
Seal

Rivet

Rivet

Cutaway of Bearing Surface

Teflon Bearing

Rivet

Steel

Bearing
Surface

Rivet

Cork

Pad

Содержание MLE/MLG23MNA

Страница 1: ...wing This manual is to be used by qualified appliance technicians only Maytag does not assume any responsibility for property damage or personal injury for improper service procedures done by an unqua...

Страница 2: ...ESPONSIBLITY TO REVIEW ALL APPROPRIATE SERVICE INFORMATION BEFORE BEGINNING REPAIRS WARNING To avoid risk of severe personal injury or death disconnect power before working servicing on appliance to a...

Страница 3: ...mbly 39 Front Panel 39 TopCover 40 Door Switch 40 Front Shroud Assembly Removal 41 Outlet Duct Shroud Tumbler Front 41 Lint Filter 42 Bearing Pads 42 Front Seal 42 Belt 42 Baffles 43 Rear Shroud Assem...

Страница 4: ...not do it yourself unless you know how To reduce the risk of fire clothes which have traces of any flammable substances such as vegetable oil cooking oil machine oil flammable chemicals thinner etc o...

Страница 5: ...might apply It is the customer s responsibility to have the wiring and fuses checked by a qualified electrician to make sure your home has adequate electrical power to operate the dryer Electrical Ser...

Страница 6: ...y of the consumer to contact a qualified electrician and have properly grounded three prong wall receptacle installed in accordance with appropriate electrical codes To avoid the risk of electrical sh...

Страница 7: ...ll your distributor or visit the Web Site at www maytagcommerciallaundry com When contacting provide product information located on rating plate Record the following Model Number ___________________ S...

Страница 8: ...the initial assistance from the booster coil Igniter A silicon carbide igniter located on the burner bracket near the main orifice It can reach a temperature of 2200o F in 30 seconds to ignite the gas...

Страница 9: ...ensor and Gas Valve HOW IT WORKS The cycles are made up of three basic operations White Colors Permanent Press and Delicates and Knits These operation are sequenced by the controls timer or microproce...

Страница 10: ...voltage available to them Step 1 Operation Dryer Controls calling for heat The red wire in the gas valve harness is normally the hot side of the line Voltage is routed to the gas valve assembly throu...

Страница 11: ...ve assembly will close Gas flow will cease When power is restored to the valve the radiant sensor will start the process again However if the radiant sensor has not cooled and the contacts are still o...

Страница 12: ...ryer current draw Analog Test Meter can be used to check for open or closed circuits measure resistance AC and DC volts and temperature Digital Test Meter can be used to check for open or closed circu...

Страница 13: ...r minute 52 RPM Rotation Drum Turning when viewed from the front Clockwise Heat Source Electric 240 volt 5600 watts 30 amp fuse Gas Single port burner 24 000 BTU hr direct ignition automatic shut off...

Страница 14: ...n electrical component is the check of a part for an open or closed circuit Electrical components fall into two general categories 1 Loads Devices that use or consume electricity Examples would includ...

Страница 15: ...ay be checked in the dryer or removed and checked Two test leads are required to check operation of the drive motor To check the motor for operation hook the test cord to terminals 4 and 5 Centrifugal...

Страница 16: ...measure of gas pressure The water column W C for a Maytag dryer is 3 5 W C for Natural gas and 11 W C for LP How to Use 1 Disconnect power supply to unit 2 Remove front panel 3 Shut off the gas to th...

Страница 17: ...as valve coil opens weak point in coil opens when stressed under heated conditions Clothes too wet due to insufficient spin out by washer Will Not Shut Off On time dry settings check the following Tim...

Страница 18: ...en transformer service switch and control board Is the exhaust tube nipple on the side of the display damaged Plug in dryer open service door is there 26 VDC across the service door switch Initiates t...

Страница 19: ...witch If problem persist replace control board No Yes Yes No Plug In Dryer Cannot Enter Or Exit Operator Mode Check adjustment of service switch and lock Check wiring and terminations between service...

Страница 20: ...ault box is in all the way If it is out the display will flash Check for the proper adjustment of vault switch Display shows Add Or Available When Not In A Cycle And No Coins Have Been Added If price...

Страница 21: ...ard Plug the dryer back in See diagnostic code troubleshooting guide Unplug dryers and check wiring and termination between door switch and control board If problem persists replace membrane switch If...

Страница 22: ...e appear Does 115 VAC appear across the motor Replace the motor Does the display show Zero minutes Replace the door switch Check wiring and termination between control board motor relay door switch mo...

Страница 23: ...etween the red wire and the white wire in the coin 1 connector greater than 10K ohms Is price suppression selected The price and amount remaining to be added do not display in price suppression mode G...

Страница 24: ...ime of day during power interruptions Check battery connector and termination If problem persists replace control board Yes No No Yes Dryer Dries Too Slowly Check for exhaust restriction No Decimal Po...

Страница 25: ...the dryer in Allow the thermostats to cool Ensure that they are close to room temperature Does the help mode show that the 140 deg thermostat is closed If the problem still exists replace the control...

Страница 26: ...eypad for more than 1 second See the single dryer diagnostic code guide Is there a diagnostic code Are all of the segments in the display working Replace the control board See the single dryer diagnos...

Страница 27: ...ad for more than 1 second while the code is displayed Did the diagnostic code reappear False indication Control board is operating normally Check the wiring between the control board and the motor Fix...

Страница 28: ...cond while the code is displayed Exit service mode and pause for 10 seconds enter service mode Did the diagnostic code cancel Low voltage was sensed on the power line but is now ok Yes No Install read...

Страница 29: ...problem persists replace control board Does each of 6 7 VAC 22 6 VAC and 20 7 VAC appear across transformer secondary Replace the transformer Inspect control board for burned components and replace i...

Страница 30: ...service switch Does display contain a diagnostic code Does control board respond to program keys Unplug dyers and check problem membrane switch tail connection See diagnostic code troubleshooting gui...

Страница 31: ...check resistance between red and white wire Is resistance greater than 10K ohms Reconnect connector and plug in dryer No Timing for the coin slide mode will cause coin drop coins to not be recognized...

Страница 32: ...5 deg thermostat Unplug dryer At room temperature is the resistance of the heating element less than 20 ohms Electric dryer only Replace heating element Check motor centrifugal switch and replace if n...

Страница 33: ...d 8 of connector while cycling vault switch If problem persists replace control board Does vault switch open and close properly Replace vault switch No Yes Dryer Runs Without Program Selection Check f...

Страница 34: ...lear diagnostic codes press a delicates keypad for at least 1 second customer cycles will be terminated If any segments of display are not flashing Replace the control board Dryers should be near room...

Страница 35: ...tested No Yes d4 or d20 Motor Control Circuit Problem Push the Perm Press program keypad to start the diagnostic program Try to Clear the diagnostic code by pressing the Delicates keypad for more than...

Страница 36: ...ode by pressing the Delicates keypad for more than 1 second while the code is displayed Exit service mode and pause for 10 seconds enter service mode Did the diagnostic code cancel Low voltage was sen...

Страница 37: ...Disconnect Ribbon connector to Touch Pad Remove Two Top Screws Touch Pad Assembly Disconnect power supply to unit 2 Remove the screws securing the Facia 3 Remove Microprocessor Board 4 Disconnect rib...

Страница 38: ...e hinge area and draw the door assembly away from the machine This will disengage the hinges from the slots in the front shroud Slots Hinge 5 Disconnect wiring harness for Coin Sensor 6 Remove Coin Dr...

Страница 39: ...hem to the other side of the door 5 Remount the door into the slots on the opposite side of the door opening in the front shroud and secure with one screw into each hinge 6 Mount the plastic hinge hol...

Страница 40: ...clips retaining the front panel to the base frame 6 Disconnect wires to Door Switch Slot Retaining Clip Top Cover 1 Disconnect power supply to unit 2 Remove the front panel Door Switch 1 Disconnect po...

Страница 41: ...to allow the front of the tumbler to rest on the teflon Rulon bearings on the shroud and tumbler front assembly Also check the front felt seal to ensure it is outside the lip of the tumbler Outlet Du...

Страница 42: ...3 Insert left hand along side of tumbler at the 8 o clock position Insert right arm under tumbler as close to blower as possible View From the Back of the Dryer Idler Pulley Motor Pulley Drive Belt Id...

Страница 43: ...as possible Rear Bulkhead Baffle Rear Mounting Screw Belt 5 Locate the belt and create a small loop with your right hand ensuring the belt is free of twist 6 Position the open end of the loop ribbed s...

Страница 44: ...the Channel of the Rear Bulkhead by Tabs Felt Tumbler Rides on Light Colored Side of Felt Note When reinstalling the seal will be mounted to the tumbler back in a clockwise rotation Start at the 11 00...

Страница 45: ...the seal facing the blower cover Air Outlet Seal Air Outlet Duct Blower Cover 1 Disconnect power supply to unit 2 Remove Front Shroud Assembly 3 Remove screws holding cover to blower housing Note One...

Страница 46: ...einstalling the Blower Cover Install the far right screw closest to the exhaust duct right most screw Continue to assembly moving to the next screw in a counterclockwise motion around the blower Insta...

Страница 47: ...sconnect power supply to unit 2 Remove Front ShroudAssembly 3 Remove the Belt and Tumbler 4 Remove the screw in front of the Blower Assembly that secures the assembly to the base frame 5 Remove wire h...

Страница 48: ...olding bracket for each coil 5 Remove retaining clip from groove in shaft 6 Remove fiber washer 7 Remove Idler Pulley and bearing 8 Remove second fiber washer Note There is a fiber washer between the...

Страница 49: ...se and to inlet duct Inlet Duct Retaining Clip Radiant Sensor Hi Limit Thermostat Combustion Cone 5 Remove tumbler back assembly Note Four screws are accessible from behind dryer 5 Remove three screws...

Страница 50: ...ss Cover 1 Disconnect power to unit 2 Remove the Access Panel 3 Locate and remove the 5 16 hex head screw located in the front of the dryer base frame This screw secures the access cover to the base f...

Страница 51: ...sor Board Coin Drop 1 Disconnect power to the machine 2 Remove the Service Panel 3 Remove three security torx screws and two pozi drive screws securing the Control Panel 3 Remove three screws securing...

Страница 52: ...two 5 16 screws holding coin drop mounting plate Swing Out and Away Remove Screws 6 Remove two screws securing coin drop to mounting plate Remove Two Screws Remove Screws Front Panel 1 Disconnect pow...

Страница 53: ...ting the panel to clear the two lower mounting brackets STACK DRYER MN Models Note The following section is exclusive to the MN stack dryers Front Panel 1 Disconnect power supply to unit 2 Remove two...

Страница 54: ...knurl nut 3 Remove Front Panel 4 Disconnect wires on switch 5 Remove screws securing Front Panel 6 Remove screws securing Selector Switch 7 Disconnect wires on Selector Switch Note Make note of wire l...

Страница 55: ...ring Front Panel 3 Swing Front Panel out and away from dryer Note Observe the wire placement connected to components attached to the Front Panel Microprocessor 1 Disconnect power supply to unit 2 Remo...

Страница 56: ...al injury or death disconnect power to unit before servicing Disassembly Procedures Motor Heater Relays 1 Disconnect power supply to unit 2 Remove Cabinet Brace Note Heater Relays are used ONLY on MDE...

Страница 57: ...2004 Maytag Appliances Company 16022904 Rev 0 57 Appendix A...

Страница 58: ...nect plug on AA1 close console apply power to dryer The dryer is now in the set up mode NOTE Before proceeding please note that an owner can choose to uncrate a new commercial machine hook it up plug...

Страница 59: ...o the number of minutes of dry time per quarter coin 1 up to 99 minutes regardless of the cost required to start the machine No credit is given for coins or debit inputs entered when the control is di...

Страница 60: ...g actuations of the coin slide to start the machine We recommend 601 setting 705 7 REGULAR DRYING MINUTES PER COIN 05 Represents the number of minutes per coin Presently set for 5 minutes per coin Exa...

Страница 61: ...mber of coins See value of coin 1 and coin 2 Adjustable from 00 to 39 by pressing the Whites Colors keypad Presently set for six 6 quarters 1 50 Press Permanent Press keypad once to advance to the nex...

Страница 62: ...keypad to advance to the next day of the week You must exit on current day of the week that it is for the special pricing to occur on the correct day Refer to chart for Special Price Days Press Perma...

Страница 63: ...once to advance to the beginning of the program mode E 00 E Add coins option Once selected the AC option may be deselected 00 This option causes the customer display to show the number of coins coin...

Страница 64: ...he end of the cycle or the last coin is deposited which ever is later 00 Not selected or OFF CE Selected or ON Press Delicates keypad once to select 00 or CE Press Permanent Press keypad once to advan...

Страница 65: ...llowing will appear if you selected 0C in the cycle counter option 900 This is a View Only and cannot be altered When cycle counter is selected the numbers will flash in sequence Example Press Permane...

Страница 66: ...e diagnostic mode 2 Lower Dryer Field Diagnostic Cycle With entire display flashing the cycle is started by pressing the LOWER DRYER PERMANENT PRESS key pad The cycle consists of seven minutes of heat...

Отзывы: