![Maytag MGD5700TW0 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/maytag/mgd5700tw0/mgd5700tw0_technical-education_1748140021.webp)
2-13
Optional 3-wire connection
Use for direct wire or power supply cord
where local codes do not permit connect-
ing cabinet-ground conductor to neutral
wire.
1. Remove center silver-colored terminal
block screw.
2. Remove neutral ground wire from exter-
nal ground conductor screw. Connect
neutral ground wire and the neutral wire
(white or center wire) of power supply
cord/cable under center, silver-colored
terminal block screw. Tighten screw.
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot
of dryer rear panel. Secure cover with
hold-down screw.
6. Connect a separate copper ground wire
from the external ground conductor screw
to an adequate ground.
7. You have completed your electrical con-
nection. Now go to “Venting Require-
ments,” page 2-17.
C. Center silver-colored terminal block screw
A. External ground conductor screw
B. Neutral ground wire
D. Neutral wire (white or center wire)
E.
" (1.9 cm) UL listed strain relief
3/4
F. Grounding path determined by a qualified electrician
A
B C
D
E
F
3. Connect the other wires to outer terminal