background image

7

Electrical Requirements

IMPORTANT: The cooktop must be electrically grounded in 
accordance with local codes and ordinances, or in the absence 
of local codes, with the National Electrical Code, ANSI/NFPA 70 
or Canadian Electrical Code, CSA C22.1.

If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path is adequate.

A copy of the above code standards can be obtained from:

 National Fire Protection Association

One Batterymarch Park

Quincy, MA 02269

CSA International

8501 East Pleasant Valley Road

Cleveland, Ohio 44131-5575

A 120 volt, 60 Hz, AC only, 15-amp, fused electrical circuit is 
required. A time-delay fuse or circuit breaker is also 
recommended. It is recommended that a separate circuit 
serving only this cooktop be provided.

Electronic ignition systems operate within wide voltage limits, 
but proper grounding and polarity are necessary. Check that 
the outlet provides 120-volt power and is correctly grounded. 

The wiring diagrams are provided with this cooktop. See 
“Wiring Diagrams” on a separate sheet. The wiring diagrams 
are located on the left underside of the cooktop base.

Gas Supply Requirements

Observe all governing codes and ordinances. 
IMPORTANT: This installation must conform with all local codes 
and ordinances. In the absence of local codes, installation must 
conform with American National Standard, National Fuel Gas 
Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest 
edition. 
IMPORTANT: Leak testing of the cooktop must be conducted 
according to the manufacturer’s instructions.

Type of Gas 

Natural Gas:

This cooktop is factory set for use with Natural gas. If 
converting to LP gas, see the “LP Gas Conversion” 
instructions provided in the package containing literature. 
The model/serial rating plate located on the underside of the 
cooktop base has information on the types of gas that can be 
used. If the types of gas listed do not include the type of gas 
available, check with the local gas supplier.

LP Gas Conversion:
Conversion must be done by a qualified service technician.

No attempt shall be made to convert the cooktop from the gas 
specified on the model/serial rating plate for use with a different 
gas without consulting the serving gas supplier. See the Gas 
Conversion instructions provided in the package containing 
literature.

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.

WARNING

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure 

gas pressure does not exceed 14" (36 cm) water 

column. 
Examples of a qualified person include: 
licensed heating personnel, 

authorized gas company personnel, and

authorized service personnel.
Failure to do so can result in death, explosion, or fire.

Содержание MGC7430DS

Страница 1: ...tallation 11 SÉCURITÉ DE LA TABLE DE CUISSON 13 EXIGENCES D INSTALLATION 14 Outillage et pièces 14 Exigences d emplacement 14 Spécifications électriques 18 Spécifications de l alimentation en gaz 18 INSTRUCTIONS D INSTALLATION 20 Installation de la table de cuisson 20 Raccordement au gaz 20 Achever l installation 22 W10597144B IMPORTANT Installer Leave installation instructions with the homeowner ...

Страница 2: ...g property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you can...

Страница 3: ... floor where cooktop is to be installed must be sealed Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances Grounded electrical supply is required See Electrical Requirements section Proper gas supply connection must be available See Gas Supply Requirements section The cooktop is designed to hang from the countertop by its side or rear flanges The gas and ...

Страница 4: ... 19 49 2 cm D 28 72 1 cm E 3 9 2 cm F 4 11 6 cm G 1 3 4 cm A 21 53 3 cm B 30 76 2 cm C 18 48 0 cm D 28 72 1 cm E 3 8 6 cm F 4 10 5 cm G 1 3 8 cm A C D B E F G A B C D E F G A 21 53 3 cm B 36 92 0 cm C 19 49 2 cm D 34 88 1 cm E 3 9 2 cm F 4 11 6 cm G 1 3 6 cm A 21 53 3 cm B 36 91 4 cm C 18 48 0 cm D 33 85 7 cm E 3 8 6 cm F 4 10 5 cm G 1 3 8 cm A B C D E F G D A B C E F G ...

Страница 5: ...top platform and bottom of uncovered wood or metal cabinet 24 61 cm minimum clearance if bottom of wood or metal cabinet is covered by not less than 0 6 cm flame retardant millboard covered with not less than No 28 MSG sheet steel 0 015 0 04 cm stainless steel or 0 024 0 06 cm aluminum or 0 020 0 05 cm copper E 36 91 4 cm top of countertop to floor F Gas line opening Wall anywhere 5 12 7 cm below ...

Страница 6: ... Front Edge H I B A C D E Cutout Product Opening Dimensions 30 76 2 cm Models Models A B Min Recommended Max Min Recommended Max KCGS550 and KCGS950 All Other 30 76 2 cm Models 28 72 4 cm 28 72 4 cm 28 73 4 cm 28 73 4 cm 29 74 3 cm 29 74 3 cm 19 49 5 cm 19 48 3 cm 19 50 2 cm 19 49 5 cm 20 50 8 cm 20 50 8 cm 36 91 4 cm Models KCGS556 and KCGS956 All Other 36 91 4 cm Models 34 88 4 cm 33 86 0 cm 35 ...

Страница 7: ...onal Fuel Gas Code ANSI Z223 1 latest edition or CAN CGA B149 latest edition IMPORTANT Leak testing of the cooktop must be conducted according to the manufacturer s instructions Typeof Gas Natural Gas This cooktop is factory set for use with Natural gas If converting to LP gas see the LP Gas Conversion instructions provided in the package containing literature The model serial rating plate located...

Страница 8: ...ied with this cooktop must be used The inlet pressure to the regulator should be as follows for proper operation Natural Gas Minimum pressure 5 12 7 cm WCP Maximum pressure 7 to 14 17 8 cm to 35 5 cm WCP LP Gas Minimum pressure 10 25 4 cm WCP Maximum pressure 14 35 5 cm WCP Contact local gas supplier if you are not sure about the inlet pressure Burner Input Requirements Input ratings shown on the ...

Страница 9: ...he smaller thread ends of the flexible connector adapters see C and G in the following illustration 2 Attach one adapter to the gas pressure regulator and the other adapter to the gas shutoff valve Tighten both adapters A Attachment screw holes for optional front and back location B Cooktop base bottom C Attachment screw D Clamping bracket end locations recommended A Edge of cooktop base bottom B ...

Страница 10: ...nd grates from parts package Align notches in burner caps with pins in burner base Align orifice holder in burner base with igniter electrode Burner caps should be level when properly positioned If burner caps are not properly positioned surface burners will not light Place burner grates over burners and caps No appliance obstructions below cooktop Suggested installation to avoid interference belo...

Страница 11: ...et to the open position Check that burner caps are properly positioned on burner bases Recheck operation of surface burners If a burner does not light at this point contact your dealer or authorized service company for assistance Check Flame Height Adjust the height of surface burner flames The surface burner low flame should be a steady blue flame approximately 6 4 mm high Adjustment for Single V...

Страница 12: ...12 Notes ...

Страница 13: ...n décès Ne pas entreposer ni utiliser de l essence ou d autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil électroménager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ Ne pas tenter d allumer un appareil Ne pas toucher à un commutateur électrique Ne pas utiliser le téléphone se trouvant sur les lieux Appeler immédiatement le fournisseur de gaz à partir du télé...

Страница 14: ... de l utilisation en encastrement et les dimensions correctes La table de cuisson doit être installée dans un emplacement à l écart des zones de forts courants d air telles que fenêtres portes et évents ou ventilateurs de chauffage Toutes les ouvertures dans le mur ou le plancher de l emplacement d installation de la table de cuisson doivent être scellées Respecter les dimensions indiquées pour le...

Страница 15: ...es locaux Au Canada l installation de cette table de cuisson doit satisfaire aux stipulations de la version la plus récente de la norme CAN CSA A240 ou des codes locaux en vigueur Dimensions du produit Modèles KCGS550ESS et KCGS950ESS Tous les autres modèles de 30 76 2 cm Modèles KCGS556ESS et KCGS956ESS Tous les autres modèles de 36 91 4 cm A 21 53 3 cm B 30 76 2 cm C 19 49 2 cm D 28 72 1 cm E 3 ...

Страница 16: ...la table de cuisson et le fond du placard de bois ou de métal non protégé Dégagement minimum de 24 61 cm lorsque le fond du placard de bois ou de métal est couvert d une plaque ignifugée d au moins 0 6 cm recouverte d une tôle d acier de 28 MSG d acier inoxydable de 0 015 0 04 cm d aluminium de 0 024 0 06 cm ou de cuivre de 0 020 0 05 cm d épaisseur au minimum E 36 91 4 cm entre le sommet du plan ...

Страница 17: ...installés avant l installation du four mural encastré sous le plan de travail Mur arrière Mur latéral Mur latéral Bord avant du plan de travail H I B A C D E Dimensions des ouvertures à découper ouverture du produit Modèles de 30 76 2 cm Modèles A B Min Recommandé Max Min Recommandé Max KCGS550 et KCGS950 Tous les autres modèles de 30 76 2 cm 28 72 4 cm 28 72 4 cm 28 73 4 cm 28 73 4 cm 29 74 3 cm ...

Страница 18: ...national américain en vigueur National Fuel Gas Code ANSI Z223 1 ou à la norme CAN CGA B149 IMPORTANT Les tests de fuite de la table de cuisson doivent être effectués selon les instructions du fabricant Type de gaz Gaz naturel Cette table de cuisson a été configurée à l usine pour l alimentation au gaz naturel Pour la conversion pour l alimentation au propane voir les instructions Conversion pour ...

Страница 19: ...la table de cuisson Détendeur de gaz Le détendeur fourni avec cette table de cuisson doit être utilisé La pression d alimentation du détendeur doit être comme suit pour un fonctionnement correct Gaz naturel Pression minimum 5 12 7 cm colonne d eau Pression maximum 7 à 14 17 8 cm à 35 5 cm colonne d eau Gaz propane Pression minimum 10 25 4 cm colonne d eau Pression maximum 14 35 5 cm colonne d eau ...

Страница 20: ...a plus petite des adaptateurs de raccord flexible voir C et G dans l illustration ci dessous 2 Fixer un adaptateur sur le détendeur et l autre adaptateur sur le robinet d arrêt de la canalisation de gaz Serrer les deux adaptateurs A Trous de vis d attache pour emplacement facultatif à l avant et à l arrière B Fond de la base de la table de cuisson C Vis d attache D Bride de fixation emplacements a...

Страница 21: ...de détection des fuites non corrosive approuvée L apparition de bulles indique la présence d une fuite Réparer toute fuite éventuelle Il ne doit pas y avoir d appareil ou d obstacle en dessous de la table de cuisson Configuration d installation suggérée pour éviter tout blocage en dessous de la table de cuisson A Entrée de la tubulure de distribution B Détendeur C Utiliser un composé d étanchéité ...

Страница 22: ...fier que la flamme est bleue à la position HIGH élevée Elle doit être propre et douce On ne doit pas observer de pointe jaune ni d effet de soufflage ou de séparation entre les flammes et le brûleur Il est normal d observer parfois des éclairs orange ceci est dû à différents éléments dans l air ou le gaz Après avoir vérifié le bon fonctionnement du brûleur tourner les boutons de commande à OFF arr...

Страница 23: ...la droite pour diminuer la hauteur de la flamme ou vers la gauche pour augmenter la hauteur de la flamme 4 Réinstaller le bouton de commande 5 Tester la flamme en tournant le bouton de commande pour le faire passer de la position LO basse à la position HI élevée et observer les flammes pour chaque réglage IMPORTANT Le réglage de la double soupape doit être effectué par un installateur qualifié A T...

Страница 24: ...W10597144B 201 Used under license in Canada All rights reserved Utilisé sous licence au Canada Tous droits réservés ...

Отзывы: