background image

Service Specifications

 

June 2005 

 

16026365 

© 2005 Maytag Services

 

3

!

WARNING

To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before 

servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires 

removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. 

Programming Mode: 

NOTE: 

The Program Code is located on the Serial Plate on this unit after the word Code.  

1.  Open the Fresh Food door and press and hold the Door Alarm Keypad 

Door
Alarm

 . 

2.  Press and hold Freezer Temperature Down Keypad

 

3.  Release the Door Alarm Keypad

 

Door
Alarm

 and wait 3 seconds.  

4.  The control will display PE to indicate the programming mode. 

Fast
Ice

Reset
Filter

Vacation
Mode

Temp
Alert

Door
Alarm

Max
Cool

Freezer

Refrigerator

Order

Replace

 

5.  Entry is confirmed by pressing the Freezer Temperature Down Keypad 

 

 once more. 

6.  The control will display the current Program CODE. This value should be validated with the Program CODE 

printed on the unit serial plate. 

PE0

Fast

Ice

Reset
Filter

Vacation
Mode

Temp

Alert

Door

Alarm

Max

Cool

Freezer

Refrigerator

Order

Replace

000

 

NOTE: 

If the Program CODE is correct, the Programming Mode is exited by closing the Refrigerator door(s). 

7.  Press the Refrigerator Temperature UP Keypad

 

 

 or Refrigerator Down Keypad

 

 

 to change the digit 

value with each key press. 

8.  The decimal point indicates the selected digit. Press the Freezer Temperature UP Keypad 

 

 to select the 

next digit. 

9.  Once the desired Program CODE is entered, press and hold the Freezer Temperature DOWN Keypad

 

 

 

until the Program CODE begins flashing indicating it has been saved. 

NOTE:

  If you attempt to enter an invalid Program CODE the control will not save the new code, but will beep. (The 

unit will NOT run with a Program CODE of 0000). Once the Program CODE has been saved the 
Programming Mode is exited by closing the Refrigerator door(s). If the new code is incorrect this process 
should be repeated after closing the Refrigerator door(s). 

The Programming mode can be exited at any time by closing the Refrigerator Door(s) or will exit if 
unattended for four minutes. 

Defrost Operation: 

The Control Board adapts the compressor run time between defrosts

 

to achieve optimum defrost intervals by 

monitoring the length of time the defrost heater is on. After initial power up, defrost interval is 4 hours 
compressor run time. Defrost occurs immediately after the 4 hours. 

 

Содержание MFD 2561HEB

Страница 1: ...ed Discharge capacitors through a 10 000 ohm resistor before handling Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization No Load Perform...

Страница 2: ...000 ohms 1 8 29 500 ohms 1 0 86 300 ohms 1 8 Condenser motor Rotation facing end opposite shaft RPM Watt Current Clockwise 1120 RPM 3 4 watts 15 115VAC 0 085 amps 15 115VAC Evaporator fan motor Rotat...

Страница 3: ...or Alarm Max Cool Freezer Refrigerator Order Replace 000 NOTE If the Program CODE is correct the Programming Mode is exited by closing the Refrigerator door s 7 Press the Refrigerator Temperature UP K...

Страница 4: ...The service test functions are performed using the refrigerator display and keypad Enter the Service Test Mode by performing the following sequence of events 1 Open the Fresh Food door and press and h...

Страница 5: ...resh Food Temperature or OP for open thermistor or SH for shorted thermistor Service Test 142 Freezer Thermistor Will Show Freezer Temperature or OP for open thermistor or SH for shorted thermistor Se...

Страница 6: ...of the Sports Fill ON or OFF Service Test 173 Ambient Light if equipped Display shows light sensor measurement Hi or Lo Night light will turn on light sensor measures Lo By changing the sensor s expos...

Страница 7: ...frost Off position to minimum time between defrosts On position Service Test 203 Show Temperature Set points Press the Refrigerator Up Keypad or Refrigerator Down Keypad to change from showing actual...

Страница 8: ...000 ohm resistor before handling Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization To avoid risk of electrical shock that can cause dea...