background image

34

SECTION V

WARRANTY INFORMATION

A.  RETURNING WARRANTY CARDS

1. Before any dryer leaves the 

manufacturer’s

 test area, a warranty card is placed on the back side of the

main door glass.  These warranty cards are intended to serve the customer where we record the individual
installation date and warranty information to better serve you should you file a warranty claim.

IMPORTANT:

A separate warranty card 

must be

 completed and returned for each individual dryer.

NOTE:

Be sure to include the installation date when returning the warranty card(s).

B.  WARRANTY

For a copy of the 

manufacturer’s

 commercial warranty covering your particular dryer(s), contact the 

Maytag

dealer from whom you purchased the equipment and request a dryer warranty form.  If the dealer 

cannot

 be

contacted or is unknown, warranty information can be obtained from the 

Maytag Co.

NOTE:

Whenever contacting the 

Maytag Co.

 for warranty information, be sure to have the dryer’s

model number

 and 

serial number

 available so that your inquiry can be handled in an

expeditious manner.

Содержание MDG30V

Страница 1: ...Installation and service must be performed by a qualified installer service agency or the gas supplier AVERTISSEMENT Assurez vous de bien suivrelesinstructionsdonn esdanscettenotice pour r duire au mi...

Страница 2: ...ammables proximit decet appareil ou de tout autre appareil We have tried to make this manual as complete as possible and hope you will find it useful The manufacturer reserves the right to make change...

Страница 3: ...operation Attention Lor des op rations d entretien des commandes tiqueter tous fils avant de les d connecter Toute erreur de c blage peut tre une source de danger et de panne WARNING UNDER NO CIRCUMS...

Страница 4: ...ayed on the equipment and or specified in the installation manual included with the dryer Dryers must not be installed or stored in an area where it will be exposed to water and or weather The wiring...

Страница 5: ...onRequirements 9 C DryerEnclosureRequirements 10 D FreshAirSupplyRequirements 11 E ExhaustRequirements 12 F ElectricalInformation 18 G GasInformation 23 H Preparation For Operation Start Up 27 I Preop...

Страница 6: ...35 A Cleaning 35 B Adjustments 36 C Lubrication 36 D LintDrawerRemoval 37 SECTION VII TROUBLESHOOTING 38 SECTION VIII DATA LABEL INFORMATION 44 A Data Label 44 SECTION IX PROCEDURE FOR FUNCTIONAL CHEC...

Страница 7: ...not damaged in a damaged shipment should be accepted but the number received and the number refused must be noted on the receipt 4 If you determine that the dryer was damaged after the trucker has lef...

Страница 8: ...appliance b DO NOT touch any electrical switch c DO NOT use any phone in your building d Clear the room building or area of ALL occupants e Immediately call your gas supplier from a neighbor s phone...

Страница 9: ...adian Electrical Codes Parts 1 2 CSA C22 1 1990 or LATEST EDITION NOTE Failure to do so willVOIDTHEWARRANTY 9 UNDER NO CIRCUMSTANCES should the dryer door switch lint drawer switch or heat safety circ...

Страница 10: ...WEIGHT 30 lbs 13 6 kg BASKET TUMBLER DIAMETER 32 3 4 83 2 cm BASKET TUMBLER DEPTH 25 5 8 65 1 cm BASKET TUMBLER MOTOR 1 2 HP 0 373 kw DOOR OPENING DIAMETER 21 1 2 54 61 cm BASKET TUMBLER VOLUME 12 5...

Страница 11: ...7 NOTE Manufacturerreservestherighttomakechangesinspecificationsatanytimewithoutnotice orobligation Specifications MDG30V...

Страница 12: ...in an upright position at ALL times The dryer can be moved to its final location while still attached to the skid or with the skid removed To unskid the dryer locate and remove the four 4 bolts secur...

Страница 13: ...ly must be provided as noted in this manual refer to Fresh Air Supply Requirements in Section D 5 Clearance provisions must be made from combustible construction as noted in this manual refer to Dryer...

Страница 14: ...ction X 12 inch 30 48 cm minimum 24 inches 60 96 cm is suggested for ease of maintenance 1 inch 2 54 cm maximum for electric dryers NOTE Airconsiderationsareimportantforproperandefficientoperation Dry...

Страница 15: ...ly to the dryers The dryer must be installed with provisions for adequate combustion and make up air supply EXAMPLE For a bank of eight 8 dryers two 2 unrestricted openings measuring 3 feet by 2 feet...

Страница 16: ...llect lint When adding ducts the ducts to be added should overlap the duct to which it is connected ALL ductwork joints must be taped to prevent moisture and lint from escaping into the building Addit...

Страница 17: ...e ductwork to the outlet cannot exceed 20 feet 6 1 meters refer to Illus A below This calculation of 20 feet 6 1 meters compensates or allows for the use of a maximum of only one 1 elbow which is the...

Страница 18: ...of elbows used exceeds the above noted specifications the cross sectional area of the ductwork must be increased in proportion to the number of elbows or duct run added IMPORTANT For extended ductwork...

Страница 19: ...cts being connected to the main common ductmust be a minimumof34 1 4 87cm dryerwidth Ductwork should be laid out in such a manner where allowances are made at rear area of the dryer for removal of rea...

Страница 20: ...16 HORIZONTAL VENTING Illus C VERTICAL VENTING Illus D...

Страница 21: ...he ductwork for periodic inspection and cleaning 9 Wherever the ductwork passes through combustible materials the opening must be 2 inches 5 08 cm larger than the duct all the way around The duct must...

Страница 22: ...ed branch circuit IMPORTANT USE ONLYCOPPER CONDUCTOR CABLE of proper ampacity and insulation in accordance with electric codes for making service connections NOTE TheuseofaluminumwirewillVOIDTHEWARRAN...

Страница 23: ...a grounded cold water pipe DO NOT ground to a gas pipe or hot water pipe The grounded cold water pipe must have metal to metal connection ALL the way to the electrical ground If there are any nonmeta...

Страница 24: ...ord or pigtail wire size must conform to rating of dryer or the dryer can be hard wired directly to the service breaker panel In both cases a strain relief must be installed where the wiring enters th...

Страница 25: ...ration at 3 phase 3 the electrical connections are made at the power distribution block located in the service box at the rear upper left corner of the dryer The ground connection is made to the coppe...

Страница 26: ...igation MDG30V GAS ELECTRICAL SERVICE SPECIFICATIONS PER DRYER IMPORTANT 208 VAC AND 240 VAC ARE NOT THE SAME When ordering specify exact voltage NOTES A B C When fuses are used they must be dual elem...

Страница 27: ...e irreparable damage to the gas valve which willVOIDTHEWARRANTY WARNING FIRE OR EXPLOSION COULD RESULT 1 Gas Supply The gas dryer installation must meet the American National Standard National Fuel Ga...

Страница 28: ...sure measured at each gas valve pressure tap must be a consistent 10 5 inches 26 1 mb water column There is no regulator or regulation provided in an L P dryer The pressure must be regulated at the so...

Страница 29: ...pliance BTUs being supplied The dryer is provided with a 1 2 N P T inlet pipe connection extending out the back area of the burner box The minimum pipe size supply line to the dryer is 1 2 N P T For e...

Страница 30: ...t be used IMPORTANT TestALLconnectionsforleaksbybrushingonasoapywatersolution liquid detergentworkswell WARNING NEVER TEST FOR LEAKSWITHAFLAME ALL components materials must conform to National Fuel Ga...

Страница 31: ...amper assembly was installed and adjusted at the factory prior to shipping However each sail switch adjustment must be checked to assure that this important safety control is functioning 5 Check bolts...

Страница 32: ...ions total of three 3 ignition attempts If there is no flame after the third ignitionattemptthemodulewilllockoutuntilitismanuallyreset Toresettheignitionsystem open and close the main door and restart...

Страница 33: ...l impellor fan isrotatinginthewrongdirection thiswillnotonly drasticallyreducedryingefficiency butitcanalsocauseprematurecomponentfailure J PREOPERATIONAL INSTRUCTIONS COIN MODELS 1 Automatic Mode Mic...

Страница 34: ...top However the microprocessorcontroller computer willcontinuetocountdownwardintime Continuation of the cycle will resume only after the door has been closed and any other of the three 3 temperature s...

Страница 35: ...themaximum ActiveGuardTime hasexpiredoruntilthedoorisopened whichever comes first The L E D display will read FILL and or AmountToStart 2 If theAnti Wrinkle programis not active or in use the L E D di...

Страница 36: ...g must be performed 1 Discontinue power to the dryer either at the external disconnect switch or the circuit breaker 2 Discontinue the heat supply a GAS MODELS discontinue the gas supply 1 SHUT OFF ex...

Страница 37: ...acting the Maytag Co be sure to give them the correct model number and serialnumbersothatyourinquiryishandledinanexpeditiousmanner B PARTS 1 Replacement parts should be purchased from the dealer from...

Страница 38: ...mpleted and returned for each individual dryer NOTE Besuretoincludetheinstallationdatewhenreturningthewarrantycard s B WARRANTY For a copy of the manufacturer s commercial warranty covering your parti...

Страница 39: ...AND LIQUIDS NOTE Suggested time intervals shown are for average usage which is considered six 6 to eight 8 operational running hoursperday IMPORTANT Dryer produces combustible lint and must be exhaus...

Страница 40: ...nnections and nonpermanent gas connections unions shutoff valves and orifices Motor and drive belts should be examined Cracked or seriously frayed belts should be replaced Tighten loose V belts when n...

Страница 41: ...r pull drawer out approximately halfway Rotate move lint drawer stop hinge refer to the illustration below downward and pull the drawer out IMPORTANT After replacing the lint drawer back into the drye...

Страница 42: ...e factory The information provided should not be misconstrued as a handbook for use by an untrained person making repairs IMPORTANT When replacing blown fuses the replacement must beof the exact ratin...

Страница 43: ...bstruction e Failed idler bearings or basket tumbler bearings E Blower motor is not operating does not start 1 Failed blower motor contactor relay 2 Failed arc suppressor A S board for reversing model...

Страница 44: ...r controller computer c Broken wire or connection somewhere between the microprocessor controller computer and the microprocessor temperature sensor J Microprocessor controller computer display reads...

Страница 45: ...omewhere in main power circuit to microprocessor controller computer O No heat for gas models only ignitor sparks burner goes on and off right away 1 Direct Spark Ignition DSI ignitor flame probe is o...

Страница 46: ...or air gas mixture at burner yellow or poor flame pattern adjust gas burner air adjustment shutters for gas models only 6 Lint screen is not being cleaned on a regular basis or often enough 7 Extracto...

Страница 47: ...sive lint build up on impellor fan blower b Failed impellor fan blower 3 Loose basket tumbler tie rod 4 Basket is out of adjustment or adjustment bolts hardware are loose 5 Failed basket tumbler suppo...

Страница 48: ...ealer certain information is required to insure proper service parts information This information is on the data label affixed to the left side panel area behind the top control access door When conta...

Страница 49: ...on your particular model 4 TYPE OF HEAT This describes the type of heat for your particular dryer gas either natural gas or liquid propane L P gas or steam 5 HEAT INPUT for GAS DRYERS This describes t...

Страница 50: ...er board reestablish power to the dryer b Start the drying cycle c Verify that the motor s and the heat indicator dots in the microprocessor controller computer light emitting diode L E D display are...

Страница 51: ...Operation Start the drying cycle When the gas burner ignites within the chosen trial for ignition time 6 seconds the flame sensor detects gas burner flame and signals the DSI module to keep the gas va...

Страница 52: ...113365 1 04 22 02 25...

Отзывы: