C. DRYER ENCLOSURE REQUIREMENTS
Bulkheads and partitions
should be
made of noncombustible materials and
must be
located a minimum of
12-inches (30.48 cm) above the dryers outer top; except along the front of the dryer which may be closed if
desired.
NOTE:
Allowances
must be
made for opening the control door.
NOTE:
Air considerations are important for proper and efficient operation.
Dryers may be positioned sidewall to sidewall. However, a 1/16 (1.5875 mm) minimum allowance
must be
made for opening and closing of the control door and the lint door. It is suggested that the dryer be positioned
about 2 feet (0.61 meters) away from the nearest obstruction for ease of installation, maintenance, and service
(to be measured from the back guard). Refer to the
illustration above
for details.
X = 12-inch (30.48 cm) minimum, 24-inches (60.96 cm) is suggested for ease of maintenance.