19
NOTE
: Component failure due to improper voltage application will VOID THE WARRANTY.
3. Grounding
A ground (earth) connection
must be
provided and installed in accordance with state and local codes. In the
absence of these codes, grounding must conform to applicable requirements of the National Electric Code
ANSI/NFPA NO. 70-LATEST EDITION
or in Canada, the installation
must conform
to applicable Ca-
nadian Standards: CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (L.P. Gas)
.
The ground connection may be to a proven earth ground at the location service panel.
For added personal safety, when possible, it is suggested that a separate ground wire (no. 18 minimum) be
connected from the ground connection of the dryer to a grounded cold water pipe.
DO NOT
ground to a gas
pipe or hot water pipe. The grounded cold water pipe must have metal to metal connection all the way to the
electrical ground. If there are any nonmetallic interruptions, such as, a meter, pump, plastic, rubber, or other
insulating connectors, they
must be
jumped out with no. 4 copper wire and securely clamped to bare metal
at both ends.
IMPORTANT
: For personal safety and proper operation, the dryer
must be
grounded.
Provisions are made for ground connection in each dryer at the electrical service connection area.
4. Electrical Connections
A wiring diagram is located inside the control box for connection data.
a. Gas Models ONLY
NOTE
:
A CIRCUIT SERVING EACH DRYER
MUST BE
PROVIDED.
1) Single-Phase (1ø) Wiring Connections and Hookup
The electrical input connections on
ALL
single-phase
(1ø) gas model dryers are made into the rear service
box located at the upper left area of the dryer.