3. Electrical Connections
NOTE:
A wiring diagram is included with each dryer and is affixed to the rear upper right guard/panel
of the dryer.
The only electrical input connections to the dryer are the 3-phase (3ø) power leads (L1, L2, and L3),
GROUND, and in the case of 4 wire service, the neutral. Providing local codes permit, power connections
to the dryer can be made by the use of a flexible underwriters laboratory listed cord/pigtail (wire size
must
conform
to rating of the dryer), or the dryer can be hard wired directly to the service breaker. In
ALL
cases, a strain relief
must be
used where the wire(s) enter the dryer electrical service (relay) box.
a. Gas Model Dryers
These electrical connections are made at the terminal block located in the electric service/relay box at
the rear, upper left hand corner of the dryer. To gain access into this service box, the service cover
(upper back guard)
must be
removed.
NOTE:
A CIRCUIT SERVICING EACH DRYER
MUST BE
PROVIDED.