Where to install it

  If the drying cabinet is to be installed with 

a connection to exhaust air ventilation, 
this must be available on the premises.  
See futher section 

“Ventilation alterna-

tives”, 

page 9

.

  A  grounded  electrical  outlet  must  be 

within  79  in.  (2  meters)  of  the  drying 
cabinet’s upper section. A 79-in.  (2-me-
ter) grounded power cord with a plug is 
connected at the top of the drying cabi-
net. If the electrical outlet is not located 
as above, the location must be adjusted 
so that an extension cord is not neces-
sary. 

  The electrical outlet shall be easily ac-

cessible  after  installation  of  the  drying 
cabinet. Take this into consideration even 
in cases when the drying cabinet is built 
into custom cabinetry or similar framing. 
For further information, see the section 

“Electrical requirements”

  The  floor  must  be  able  to  support  the 

weight of the cabinet 133 lbs (60 kg). 

  The floor must be flat with a slope under 

the cabinet of no more than 1 in.  (2.5 
cm).

  The drying cabinet is only intended for 

installation indoors and at temperatures 
above 0°C (32°F).

  The drying cabinet may not be located in 

environments where pressurized water 
is used for cleaning. 

 

Содержание MDE 1100AES

Страница 1: ...MDE 1100AES Use and Care Guide Drying cabinet...

Страница 2: ...hen you buy an MAYTAG product we want you to feel assured that the inside is as good as the outside and that the ethics and morals on which we built this machine are just as high as the quality and pe...

Страница 3: ...he door the other way round 13 Horizontal adjustment 14 Mounting 14 Mounting into custom cabinetry 15 Ventilation connection 17 Electrical connection 17 Final check 18 How to use the drying cabinet 19...

Страница 4: ...t should be installed or kept in storage indoors Follow Asko s recommendations concer ning repairs and spare part replacement If a softening agent or antistatic substance is used the manufacturer s in...

Страница 5: ...ng cabinet 1 Exhaust collar 2 Drying cabinet model 3 Hanger hooks 4 Identi cation plate inside 5 Upper hanger section 6 Middle hanger section 7 Lower hanger section 8 Shoe rack 9 Air intake 10 Control...

Страница 6: ...6 1 2 Control panel 1 Temperature setting 2 Timer...

Страница 7: ...on must be adjusted so that an extension cord is not neces sary The electrical outlet shall be easily ac cessible after installation of the drying cabinet Take this into consideration even in cases wh...

Страница 8: ...ently connected The electrical outlet should be placed in such a way that the plug can easily be pulled out whenever necessary WARNING Check that mains supply complies with the data on the identi cati...

Страница 9: ...air can be discharged in two ways Ventilation out into the room where the drying cabinet is located Connection to a vent duct exhaust air ventilation Ventilation out into the room where the drying cab...

Страница 10: ...g cabinet With a draft stabilizer The ventilation duct valve is replaced by a draft stabilizer included in the delivery See also the section Connect Ventilation page 17 Do not assemble the ventilation...

Страница 11: ...Connect Ventilation page 17 1 Adapter 2 Air intake 3 Ventilation duct valve The drying cabinet permanently installed and connected to the evacuation duct Permanently installed and connected to a vent...

Страница 12: ...ribu tor should immediately be noti ed of any damage defects or even missing parts Check that all the safety devices used for transportation have been removed before the drying cabinet is connected Co...

Страница 13: ...s it right down on to the bottom hinge on the opposite side 4 Disengage the hinge pin of the upper hinge 2 and place it on the opposite side 5 Completely unscrew the glove hangers on the inside of the...

Страница 14: ...to the holes 1 Shoe rack 2 Bubble level 3 Allen wrench Mounting 1 Take out the upper hanging section and mark the centres of the holes on the woo den strip see the section Installing in the cabinet mo...

Страница 15: ...ark the position of the holes on the back wall with a pencil 5 Push back the hanging section shut the door and hold it in place with adhesive tape Pull out the entire drying cabinet 6 Use a wooden str...

Страница 16: ...nt screws 2 Hole marking 3 Air ow 4 Wooden strip in two parts part of the drying cabinet ts well into the custon cabinetry 9 Adjust the position of the drying cabinet horizontally according to the ins...

Страница 17: ...the screw holes and screw the exhaust collar into place 2 Connect the vent pipe if the drying cabi net is built in or press the supplied only certain markets exible hose into place See the section Ven...

Страница 18: ...et does not start check the following that the door of the drying cabinet is shut properly that the temperature and time selector knobs are activated that the drying cabinet is connected to the mains...

Страница 19: ...in the drying cabinet according to how much room they take up not according to their weight For optimum ef ciency do not lay artic les at on the upper hanging section Long clothes nearest to the wall...

Страница 20: ...or the remaining damp garments Do not overload the drying cabinet The items will become creased and drying uneven Instead leave a certain distance between items of washing if this is pos sible If ther...

Страница 21: ...ts blouses silk garments washable knitted products Low 3 Sturdy working clothes denim cotton garments training sweaters cotton Normal Do not use any heat when drying articles of clothing lled with foa...

Страница 22: ...he cabinet This can disturb the way the cabinet functions which can in turn lead to a breakdown To avoid this problem the air intake ori ce and the top of the cabinet should be vacuum cleaned at least...

Страница 23: ...normally the drying cabinet must obligatorily be installed in a room where the temperature is above 0 C Check what is hanging in the drying cabinet See the section Loading Control the settings They s...

Страница 24: ...e and its serial number The designation of the model is inscribed on the cabinet control panel The type and the serial number are inscribed on the identi ca tion plate which is placed on the inside of...

Страница 25: ...te Electricity connection Single phase 230 V 50 60 Hz Motor 35 W Heating element output 1500 W Overheating protection Yes Timer Adjustable up to 4 hours Hanging length 16 metres Dimensions Height 1730...