20
16026945
©2006 Maytag Services
Disassembly Procedures
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge
capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be
connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Inner Door Panel
Removal of the Inner Door Panel will allow access to the
Microprocessor Board, Door Switches, Detergent / Rinse
Aid Dispenser, and Vent Assembly.
Removal
1.
Disconnect power to the machine.
2.
Open the Dishwasher door.
3.
Remove the 11 Torx™ screws along the sides and
top of the Inner Door Panel.
4.
Separate the Inner Door Panel from the Outer Door.
5.
Disconnect wires from the Vent and Dispenser Wax
Motors before pulling the Inner Door Panel away
from the Dishwasher.
Detergent / Rinse Dispenser Mechanism
and Reservoir
Checking Operation
1.
Disconnect power to the machine.
2.
Remove the Inner Door Panel, see "Inner Door Panel"
removal procedure.
3.
Snap the Detergent Door shut.
4.
Gently lift the lever of the dispenser mechanism until
a click is herd. The Detergent Door releases. Re-
lease the lever.
5.
Lift the lever again. Now the actuator will lift the Rinse
Aid Plunger.
Содержание MDC4650AW Series
Страница 8: ...General Information 8 16026945 2006 Maytag Services ...
Страница 34: ...34 16026945 2006 Maytag Services NOTES ...
Страница 35: ... 2006 Maytag Services 16026945 A 1 AppendixA ...
Страница 36: ...A 2 16026945 2006 Maytag Services NOTES ...
Страница 38: ...A 4 16026945 2006 Maytag Services NOTES ...
Страница 40: ...B 2 16026945 2006 Maytag Services NOTES ...