Tank (Sediment) Cleaning

Sediment build-up on the tank bottom may create varying amount
of noise, if left in the tank will cause permanent tank failure.  In
some water areas, sediment can be removed by draining off
approximately one gallon of water each month.

Vent System Inspection

At least once a year a visual inspection should be made of the
venting system.  You should look for:

Obstructions which could cause improper venting.  The
combustion and ventilation air flow must not be obstructed.

Damage or deterioration which could cause improper venting
or leakage of combustion products.

Rusted flakes around top of water heater.

Be sure the vent piping is properly connected to prevent escape
of dangerous flue gases which could cause deadly
asphyxiation.

Obstructions and deteriorated vent systems may present serious
health risk or asphyxiation.

Chemical vapor corrosion of the flue and vent system may occur
if air for combustion contains certain chemical vapors. Spray
can propellants, cleaning solvents, refrigerator and air
conditioner refrigerants, swimming pool chemicals, calcium and
sodium chloride, waxes, bleach and process chemicals are
typical compounds which are potentially corrosive.

If after inspection of the vent system you found sooting or
deterioration, something is wrong.  

Call Maytag Customer

Service at 1-800-788-8899 for an authorized servicer or your
local gas supplier to correct the problem and clean or
replace the flue and venting before resuming operation of
the water heater.

Burner Inspection

Flood damage to a water heater may not be readily visible or
immediately detectable. However, over a period of time a flooded
water heater will create dangerous conditions which can cause
DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.
Contact the Maytag dealer from whom the appliance was
purchased or 

call Maytag Customer Service at

1-800-788-8899 for an authorized servicer to replace a
flooded water heater. Do not attempt to repair the unit! It
must be replaced!

At least once a year a visual inspection should be made of the
main burner and pilot burner, see Figure 24.

You should check for sooting. Soot is not normal and will impair
proper combustion.

Soot build-up indicates a problem that requires correction before
further use. Turn “OFF” gas to water heater and
leave off until repairs are made, because failure to correct the
cause of the sooting can result in a fire causing death, serious
injury, or property damage.

FIGURE 24.

Burner Cleaning

If inspection of the burner shows that cleaning is required, turn
the gas control knob clockwise ( 

 ) to the “OFF” position,

depressing slightly.

NOTE: The knob cannot be turned from “PILOT” to “OFF”
unless knob is depressed slightly.  DO NOT FORCE.

Loose deposits on or around the burner can be removed by
carefully using the hose of a vacuum cleaner inserted through
the access door of the water heater. If the Burner

 

needs to be

SERVICE AND MAINTENANCE

NATURAL

PROPANE

Содержание HRX75CQRSCGA

Страница 1: ...FOR POTABLE WATER HEATING ONLY NOT SUITABLE FOR SPACE HEATING NOT FOR USE IN MANUFACTURED MOBILE HOMES Model Number HRX75XQRSCGA HRX75CQRSCGA For Your Safety AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER GAS WATER HEATER USER S GUIDE Series Ten ...

Страница 2: ...uding a thorough understanding of the requirements of the Natural Gas and Propane Installation Code as it relates to the installation of gas fired water heaters The Service Specialist also has a thorough understanding of this instruction manual and is able to perform repairs strictly in accordance with the service guidelines provided by the manufacturer Gas Supplier The natural gas or propane util...

Страница 3: ...3 SAFETY PRECAUTIONS ...

Страница 4: ...13 14 Temperature Pressure Relief Valve 14 15 Filling the Water Heater 15 16 Venting 16 17 Gas Piping 17 18 Sediment Trap 18 OPERATING INSTRUCTIONS 19 21 Lighting Operating Label 19 20 Temperature Regulation 21 SERVICE AND MAINTENANCE 22 24 Tank Sediment Cleaning 22 Vent System Inspection 22 Burner Inspection 22 Burner Cleaning 22 23 Housekeeping 23 Anode Rod Inspection 23 Temperature Pressure Rel...

Страница 5: ...per operation of the water heater and your safety Since we cannot put everything on the first few pages READ THE ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER The installation must conform with these instructions and local code authority having jurisdiction In the absence of local codes installations shall comply with the Natural Gas and Propane Installation Code CAN CSA B...

Страница 6: ...SS AND 28 711 mm DIAMETER PART NO 66001012 FOR WATER HEATERS HAVING A DIAMETER 26 660 mm OR LESS Tools You may or may not need all these tools depending on your type of installation These tools can be purchased at your local hardware store Pipe Wrenches 2 14 356 mm Screwdriver Tin Snips 6 1 82 m Tape or Folding Ruler Garden Hose Drill Pipe Dope or Teflon Tape Additional Tools Needed When Sweat Sol...

Страница 7: ... the vent pipe can be lifted off after any screw or other attached devices are removed Dispose of the draft hood The new water heater has the draft hood which must be used for proper operation 6 If you have copper piping to the water heater the two copper water pipes can be cut with a hacksaw approximately four inches away from where they connect to the water heater This will avoid cutting off pip...

Страница 8: ...let Water Shut off Valve O Cold Water Inlet P Inlet Dip Tube Q Temperature Pressure Relief Valve R Rating Plate S Flue Baffle s T Thermostat U Drain Valve V Pilot and Main Burner W Flue X Drain Pan Y Thermostat Shield optional V PILOT MAIN BURNER NATURAL GAS T THERMOSTAT ALL PIPING MATERIALS TO BE SUPPLIED BY CUSTOMERS CLOSED WATER SYSTEMS ARE THOSE WITH BACK FLOW PREVENTION DEVICES INSTALLED IN T...

Страница 9: ...g hot water in your home fits into one of these groups or if there is a local code or province law requiring a certain temperature water at the hot water tap then you must take special precautions In addition to using the lowest possible temperature setting that satisfies your hot water needs a means such as a Mixing Valve shall be used at the hot water taps used by these people or at the water he...

Страница 10: ...ed by a leak detector or water shut off device used in conjunction with a piped drain pan These devices are available from some plumbing supply wholesalers and retailers and detect and react to leakage in various ways Sensors mounted in the drain pan that trigger an alarm or turn off the incoming water to the water heater when leakage is detected Sensors mounted in the drain pan that turn off the ...

Страница 11: ... combustion air can result in a fire or explosion and cause death serious bodily injury or property damage FIGURE 10 If this water heater will be used in beauty shops barber shops cleaning establishments or self service laundries with dry cleaning equipment it is imperative that the water heater or water heaters be installed so that combustion and ventilation air be taken from outside these areas ...

Страница 12: ...liances Located in Confined Spaces CONFINED SPACE is a space whose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kW of the aggregate input rating of all appliances installed in that space A ALL AIR FROM INSIDE BUILDINGS See Figures 10 and 11 The confined space shall be provided with two permanent openings communicating directly with an additional room s of sufficient volume s...

Страница 13: ...aces may create conditions requiring special attention to avoid unsatisfactory operation of installed gas utilization equipment Water Piping HOTTER WATER CAN SCALD Water heaters are intended to produce hot water Water heated to a temperature which will satisfy clothes washing dish washing cleaning and other sanitizing needs can scald and permanently injure you upon contact Some people are more lik...

Страница 14: ...ntimely corrosion of hot and cold water fittings it is strongly recommended that di electric unions or couplings be installed on this water heater when connected to copper pipe Figure 16 shows the typical attachment of the water piping to the water heater The water heater is equipped with 1 NPT water connections for 75 gallon models NOTE If using copper tubing solder tubing to an adapter before at...

Страница 15: ...nnect tubing directly to discharge drain unless a 6 inch air gap is provided To prevent bodily injury hazard to life or property damage the relief valve must be allowed to discharge water in quantities should circumstances demand If the discharge pipe is not connected to a drain or other suitable means the water flow may cause property damage FIGURE 17 The Discharge Pipe Shall not be smaller in si...

Страница 16: ...of this gas fired water heater the correct vent pipe diameter must be utilized Any additions or deletions of other gas appliances on a common vent with this water heater may adversely affect the operation of the water heater Consult your Maytag Customer Service Center at 1 800 788 8899 or gas supplier if any such changes are planned For proper venting in certain installations a larger diameter ven...

Страница 17: ...r square inch 3 5kPa the damage to the gas control valve could result in a fire or explosion from leaking gas If the main gas line Shut off serving all gas appliances is used also turn OFF the gas at each appliance Leave all gas appliances shut OFF until the water heater installation is complete A gas line of sufficient size must be run to the water heater Consult the current edition of the CAN CS...

Страница 18: ...ystem at test pressures equal to or less than 1 2 pound per square inch 3 5kPa Connecting the gas piping to the gas control valve of the water heater can be accomplished by either of the two methods shown in Figures 20 and 21 Sediment Traps Contaminants in the gas lines may cause improper operation of the gas control valve that may result in fire or explosion Before attaching the gas line be sure ...

Страница 19: ...19 OPERATING INSTRUCTIONS ...

Страница 20: ...an or gas supplier If the pilot will not stay lit after several tries turn the gas control knob to OFF Figure A and call your service technician or gas supplier 9 Replace inner and outer burner doors 10 At arm s length away turn the gas control knob counterclockwise to on Figure C 11 Set thermostat to desired setting See Figure 1 CAUTION Hotter water increases the risk of scald injury Consult the ...

Страница 21: ...g by up to 30 F 16 7 C If you experience this type of use you should consider using lower temperature settings to reduce scald hazards Any water heater s intended purpose is to heat water Hot water is needed for cleansing cleaning and sanitizing bodies dishes clothing Untempered hot water can present a scald hazard Depending on the time element and the people involved adults children elderly infir...

Страница 22: ...r or your local gas supplier to correct the problem and clean or replace the flue and venting before resuming operation of the water heater Burner Inspection Flood damage to a water heater may not be readily visible or immediately detectable However over a period of time a flooded water heater will create dangerous conditions which can cause DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE Contact t...

Страница 23: ...od that appears to be intact Replacement of a depleted anode rod can extend the life of your water heater Inspection should be conducted by a qualified technician At a minimum the anode s should be checked annually after the warranty period Temperature Pressure Relief Valve Operation The temperature pressure relief valve must be manually operated at least once a year When checking the temperature ...

Страница 24: ...eck draft hood operation by performing a worst case depressurization of the building With all doors and windows closed and with all air handling equipment and exhaust fans operating such as furnaces clothes dryers range hoods and bathroom fans a match flame should still be drawn into the draft hood of the water heater with its burner firing If the flame is not drawn toward the draft hood shut off ...

Страница 25: ...od see parts section for corrosion protection of the tank Certain water conditions will cause a reaction between this rod and the water The most common complaint associated with the anode rod is one of a rotten egg smell This odor is derived from hydrogen sulfide gas dissolved in the water The smell is the result of four factors which must all be present for the odor to develop a concentration of ...

Страница 26: ...high water pressure in your area E The temperature pressure relief valve may be leaking at the tank fitting F Water from a drain valve may be due to the valve being slightly opened G The drain valve may be leaking at the tank fitting H Combustion products contain water vapor which can condense on the cooler surfaces of the tank Droplets form and drip onto the burner or run on the floor This is com...

Страница 27: ...ol Replace Gas Control Dirty pilot burner Clean pilot assembly Thermocouple tip is not in contact with pilot flame Insert thermocouple correctly PILOT OUTAGE Thermocouple malfunction Replace pilot assembly and or thermocouple Defective Gas Control Replace Gas Control Heater not lit or thermostat not on Refer to LIGHTING INSTRUCTIONS Thermostat set too low Refer to TEMPERATURE REGULATION Heater und...

Страница 28: ...9 66001846 5 Compression Fitting 66001837 66001837 6 Dip Tube 9006214 9006214 7 Draft Hood 66001678 66001678 8 Draft Hood Bracket 66001679 66001679 9 Drain Valve 66001015 66001015 10 Drain Valve Washer 66001021 66001021 11 Flue Baffle 66001677 66001677 12 Gas Control Valve 66001680 66001773 13 Inner Door 66001692 66001692 14 Instruction Manual 197667 001 197667 001 15 Nipple Hot Outlet 66001684 66...

Страница 29: ......

Страница 30: ...30 NOTES ...

Страница 31: ...31 NOTES ...

Страница 32: ...a leak occurs in the tank a new water heater of the closest capacity and quality then available will be replaced free of charge for the water heater with the owner paying all other costs including labor mileage and transportation If the water heater is subjected to commercial institutional industrial or non residential use the above warranty coverage for the tanks that are proved to be defective i...

Страница 33: ...osion ou pour éviter tout dommage matériel toute blessure ou la mort Ne pas entreposer ni utiliser d essence ou ni d autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Ne touchez à aucun interrupteur ne pas vous servir des téléphones se trouvant dans le bâtiment Appelez immédiate...

Страница 34: ...prend une connaissance approfondie des exigences du Code d installation du gaz naturel et du propane relatives à l installation des chauffe eau au gaz Le centre de service comprend en outre parfaitement le présent manuel d instructions et est en mesure d effectuer des réparations conformément aux directives d entretien du fabricant Fournisseur de gaz Entreprise ou service public de distribution de...

Страница 35: ...3 MESURES DE SÉCURITÉ ...

Страница 36: ...Tuyauterie de gaz 17 18 Collecteur d impuretés 18 INSTRUCTIONS DE FONCTIONNEMENT 19 21 Instructions d allumage et d utilisation 19 20 Réglage de la température 21 ENTRETIEN ET RÉPARATION 22 24 Nettoyage du réservoir dépôts 22 Inspection du système de ventilation 22 Inspection du brûleur 22 Nettoyage du brûleur 22 Entretien courant 23 Inspection de la tige d anode 23 Fonctionnement de la soupape de...

Страница 37: ...uelques premières pages du manuel IL CONVIENT DE LIRE LA TOTALITÉ DU MANUEL AVANT D INSTALLER OU D UTILISERLECHAUFFE EAU L installation doit être conforme aux présentes directives et aux codes réglementaires locaux S il n existe pas de codes locaux l installation doit satisfaire au Code d installation du gaz naturel et du propane CAN CSA B149 1 On peut se procurer ce document auprès de l Associati...

Страница 38: ...m OU MOINS Outils Suivant le type d installation les outils ci dessous peuvent être utiles Ils sont offerts dans les quincailleries Clé à tubes 2 14 po 356 mm Tournevis Cisaille de ferblantier Ruban à mesurer ou règle pliante de 6 pi 1 82 m Tuyau d arrosage Perceuse Pâte à joint ou ruban de téflon Outils supplémentaires requis pour la soudure à l étain Coupe tube ou scie à métaux Bouteille de prop...

Страница 39: ...a plupart des cas on peut retirer l évent en le soulevant après avoir enlevé les vis ou autres pièces qui le retiennent Mettre l ancien coupe tirage au rebut car le nouveau chauffe eau exige un coupe tirage spécial 6 Si les conduites d eau sont en cuivre on peut tailler les deux tuyaux d eau avec une scie à métaux à environ quatre pouces du point de raccordement au chauffe eau Éviter de les couper...

Страница 40: ...de combustion T Thermostat U Robinet de vidange V Veilleuse et brûleur principal W Conduit d évacuation des gaz de combustion X Bac d évacuation Y Dispositif de verrouillage pour thermostat optionnel V VEILLEUSE ET BRÛLEUR PRINCIPAL GAZ NATUREL T THERMOSTAT DISPOSITIF DE VERROUILLAGE POUR THERMOSTAT OPTIONNEL Y THERMOCOUPLE V VEILLEUSE ET BRÛLEUR PRINCIPAL PROPANE INSTALLER CONFORMÉMENT AUX CODES ...

Страница 41: ...es les enfants et les personnes handicapées physiquement ou mentalement Si ces personnes utilisent l eau chaude ou si une loi provinciale ou un code local exige de limiter la température de l eau chaude aux robinets des précautions particulières doivent être prises En plus de régler la température au minimum on peut installer un dispositif tel qu une vanne de mélange à la sortie du chauffe eau ou ...

Страница 42: ...d évacuation relié à un drain Ces dispositifs vendus dans certaines grandes quincailleries détectent les fuites et y réagissent de différentes manières Il peut s agir de capteurs fixés dans le bac d évacuation qui déclenchent une alarme ou coupent l arrivée d eau au chauffe eau lorsqu une fuite est détectée de capteurs fixés dans le bac d évacuation qui coupent l arrivée d eau principale de la mai...

Страница 43: ...streindre la circulation de l air de ventilation En cas de doute ou pour des rensei gnements supplémentaires appeler le fournisseur de gaz Toute négligence à prévoir la quantité d air de combustion nécessaire peut causer un incendie ou une explosion et entraîner des blessures graves ou mortelles et des dommages matériels FIGURE10 Pour les installations dans un salon de beauté un salon de coiffure ...

Страница 44: ...rage pare vapeur etc il faut prévoir un apport d air Pour ce faire utiliser une des méthodes décrites à la section Air de combustion et air de ventilation en espace clos Air de combustion et air de ventilation en espace clos On entend par ESPACE CLOS un espace dont le volume est inférieur à 50 pi3 par 1 000 Btu h 4 8 m3 kW de débit calori fique nominal total de tous les appareils installés dans ce...

Страница 45: ...s créées par les foyers ou les dispositifs d évacuation mécanique L utilisation de ventilateurs d évacuation de systèmes de ventilation de sécheuses ou de foyers crée des conditions qui exigent une attention particulière pour éviter le fonctionnement insatisfaisant des appareils au gaz Tuyauterie d eau L EAU TRÈS CHAUDE PEUT OCCASIONNER DES BRÛLURES Les chauffe eau sont conçus pour produire de l e...

Страница 46: ...agréé capable de remédier à la situation REMARQUE Si le chauffe eau est raccordé à une tuyauterie en cuivre il est fortement recommandé de lui installer des raccords ou manchons diélectriques pour protéger le système contre la corrosion prématurée des raccords de la tuyauterie d eau chaude et d eau froide La figure 16 présente le raccordement type de la tuyauterie d eau au chauffe eau Le chauffe e...

Страница 47: ...voir Ne pas raccorder l extrémité de la conduite directement dans le drain d évacuation sans laisser un espace d air de 6 po Pour éliminer les risques de dommages matériels et de blessures graves ou mortelles la soupape de décharge doit être en mesure d évacuer la quantité d eau imposée par les circonstances Si la conduite d évacuation n est pas raccordée à un drain ou à un dispositif d évacuation...

Страница 48: ...e diamètre suffisant Si d autres appareils au gaz partagent l évent tout ajout ou retrait d un appareil branché à l évent commun risque de nuire au fonctionnement du chauffe eau Pour obtenir plus de détails sur ce genre de changement consulter le centre de service à la clientèle Maytag au 1 800 788 8899 ou le fournisseur de gaz Dans certaines installations un évent de plus grand diamètre peut s av...

Страница 49: ...t du type indiqué sur la plaque signalétique du chauffe eau La pression du gaz à l entrée du chauffe eau ne doit pas dépasser 14 po CE 2 6 kPa pour le gaz naturel ou le gaz propane GPL Si le régulateur de gaz est soumis à une pression dépassant 1 2 lb po2 3 5 kPa il peut être endommagé et causer des fuites de gaz entraînant des risques d incendie ou d explosion Si le système de distribution de gaz...

Страница 50: ...on de gaz Pour les tests à une pression égale ou inférieure à 1 2 lb po2 3 5 kPa le chauffe eau n a pas à être coupé du système mais il doit être isolé de la conduite d alimentation de gaz par la fermeture de son robinet d arrêt Le raccordement de la conduite de gaz au régulateur de gaz du chauffe eau peut se faire suivant l une des méthodes représentées ci après fig 20 21 Collecteur d impuretés L...

Страница 51: ...19 ...

Страница 52: ...ens horaire 3 Enfoncez légèrement le bouton d admission du gaz puis tournez le dans le sens horaire jusqu à la position OFF FERMÉ fig A REMARQUE Ce bouton ne peut être tourné de la position PILOT VEILLEUSE à la position OFF que s il est légèrement enfoncé Ne le forcez pas 4 Retirez les panneaux d accès interne et externe se trouvant dessous et derrière la commande de gaz 5 Attendre cinq minutes po...

Страница 53: ...pératures aux points de prélèvement qui dépassent de 30 F 16 7 C la température de consigne Avec ce type de consommation il est souhaitable de régler le thermostat à une température plus basse afin de réduire les risques de brûlures Le but de tout chauffe eau est de chauffer l eau L eau chaude non tempérée nécessaire pour le nettoyage le rinçage et la désinfection hygiène personnelle lave vaissell...

Страница 54: ...réé ou avec le fournisseur de gaz afin de faire corriger le défaut et nettoyerouremplacerletuyaud évacuationdesgazetlesystème de ventilation avant de remettre le chauffe eau en marche Inspection du brûleur Les dégâts causés par l inondation d un chauffe eau ne sont pas toujours immédiatement visibles et décelables Cependant après un certain temps la détérioration progressive du chauffe eau peut ca...

Страница 55: ... anode apparemment intacte Le remplacement de la tige d anode lorsqu elle est usée prolongera la durée de vie du chauffe eau L inspection de la tige d anode doit être faite par un technicien qualifié L inspection doit être faite au moins une fois par an après l expiration de la garantie Fonctionnement de la soupape de décharge à sécurité thermique La soupape de décharge doit être ouverte manuellem...

Страница 56: ...e tirage Pour vérifier le fonctionnement du coupe tirage effectuer un test sous dépressurisation maximale du bâtiment Toutes les portes et les fenêtres étant fermées et tous les équipements de traitement de l air et ventilateurs d évacuation chaudières sécheuses hottes aspirantes et ventilateurs de salle de bain etc étant en marche allumer une allumette et vérifier que la flamme est attirée par le...

Страница 57: ...ertains bruits produits par la dilatation et la contraction de pièces métalliques pendant les cycles de réchauffement et de refroidissement n indiquent pas la présence d une situation nuisible ou dangereuse Pendant les périodes d échauffement et de refroidissement la condensation cause un grésillement et un bruit de craque ment dans la région du brûleur Ces bruits sont considérés comme normaux Voi...

Страница 58: ...ns un raccord C Eau sur le raccord de la tige d anode Fuite possible D Léger écoulement d eau de la soupape de décharge à sécurité thermique Peut être causé par la dilatation thermique de l eau du système ou par une pression d alimentation d eau élevée E Fuite possible de la soupape de décharge au niveau du raccord avec le réservoir F Un écoulement d eau peut apparaître à la sortie du robinet de v...

Страница 59: ...ocouple non en contact avec Insérer le thermocouple convenablement la flamme de la veilleuse Mauvais fonctionnement du thermocouple Remplacer la veilleuse ou le thermocouple Commande de gaz défectueuse Remplacer la commande de gaz Chauffe eau éteint ou thermostat fermé Voir les instructions d allumage Thermostat réglé trop bas Voir la section Réglage de la température Chauffe eau de capacité insuf...

Страница 60: ...itif de verrouillage pour thermostat optionnel 66001667 66001667 21 Thermocouple 9000283 66001847 18 21 No DE MODÈLE HRX75XQRS 75 gallons au gaz naturel HRX75CQRS 75 gallons au gaz propane Pour des pièces de rechange à l occasion d un service d entretien ou de réparation communiquer avec le service à la clientèle Maytag au 1 800 788 8899 pour obtenir le nom d un agent de service agréé Lors de l ap...

Страница 61: ...29 NOTES ...

Страница 62: ...30 NOTES ...

Страница 63: ...31 NOTES ...

Страница 64: ...le chauffe eau est remplacé par un chauffe eau neuf de capacité et de qualité les plus équivalentes possible gratuit les autres frais dont les frais de main d œuvre de déplacement et de transport devant être acquittés par le propriétaire Si le chauffe eau fait l objet d un usage commercial institutionnel industriel ou non résidentiel la période de couverture ci dessus pour les réservoirs avérés dé...

Отзывы: