Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
©2006 Maytag Services
16026969
21
Illustration Component
Testing
Results
High voltage fuse
Test continuity of terminals.
Indicates continuity, if not replace
fuse.
Slow acting relay assembly
Disconnect black wire from relay and
measure voltage from neutral (blue wire on
Filter Assembly) to relay terminal with black
wire removed.
Power Out terminals .......................................
230 VAC
If no power out, replace assembly
Fuse block / Filter assembly
Power In terminals ..........................................
Power Out terminals .......................................
230 VAC
230 VAC
If no power in, check power outlet
If no power out, check fuses
(Electronic)
Interlock switch assembly
Disconnect wires to switch.
With door open measure resistance from:
Monitor – Terminals 3 - 4 ..........................
Primary – Terminals 1 - 2 ..........................
Secondary – Terminals 5 - 6 .....................
Lamp – Terminals 7 – 8 ............................
Lamp – Terminals 7 – 9 ............................
With door closed measure resistance from:
Monitor – Terminals 3 - 4 ..........................
Primary – Terminals 1 - 2 ..........................
Secondary – Terminals 5 - 6 .....................
Lamp – Terminals 7 – 8 ............................
Lamp – Terminals 7 – 9 ............................
After verifying or replacing the module, re-
connect wires to switch and check operation of
monitor circuit before operating the oven.
Indicates continuity
Infinite
Ω
Infinite
Ω
Infinite
Ω
Indicates continuity
Infinite
Ω
Indicates continuity
Indicates continuity
Indicates continuity
Infinite
Ω
(Mechanical)
Interlock switch assembly
Disconnect wires to switch.
With door open measure resistance from:
Monitor – Terminals 3 - 4 ........................
Primary – Terminals 1 - 2 ........................
Secondary – Terminals 5 - 6 ...................
With door closed measure resistance from:
Monitor – Terminals 3 - 4 ........................
Primary – Terminals 1 - 2 ........................
Secondary – Terminals 5 - 6 ...................
After verifying or replacing the module, re-
connect wires to switch and check operation of
monitor circuit before operating the oven.
Indicates continuity
Infinite
Ω
Infinite
Ω
Infinite
Ω
Indicates continuity
Indicates continuity
Error codes
E-20
Replace Control Board
Illustration Component
Testing
Results
Keyboard assembly
12
11
10
9
8
7
6
5
4
3
2
1
Continuity is indicated as
100
Ω
and below.
Pad
10 ................................
9..................................
8..................................
7..................................
6..................................
5..................................
4..................................
3..................................
2..................................
1..................................
STOP/RESET .............
START/+30 SEC .........
POWER LEVEL ..........
DEFROST ...................
CHECK PROGRAM ....
PROGRAM..................
QTY 2X .......................
Trace
1 & 8
3 & 9
2 & 9
1 & 9
7 & 8
6 & 8
5 & 8
4 & 8
3 & 8
2 & 8
4 & 9
5 & 9
6 & 9
7 & 9
1 & 10
2 & 10
3 & 10
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Содержание ALD510
Страница 4: ...4 16026969 2006 Maytag Services Important Safety Information...
Страница 5: ...2006 Maytag Services 16026969 5 Important Safety Information...
Страница 6: ...6 16026969 2006 Maytag Services Important Safety Information...
Страница 30: ...2006 Maytag Services 16026969 A 1 Appendix A...