Component Testing Procedures

!

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless
testing requires power.

16022195 Rev. 0

March 2003

2

Illustration

Component

Test Procedure

Results

270

°

valve

Verify gas is supplied.

Orifice adjusted for

Natural or LP.

Adjust set screw for simmer
control.

To replace burner valve(s),
complete assembly must be
replaced (manifold and valves).

See conversion section.

Spark 270

°

switch

Test for voltage at terminals .......

Disconnect wiring and check for
continuity in LITE position...........

120 VAC

Continuity in LITE position.

Spark ignition
electrode

Test for resistance of spark lead

Test ignitor to chassis.................

Continuity

No continuity from ignitor to
chassis.

Spark ignition
electrode

Test for resistance of spark lead

Test ignitor to chassis.................

Continuity

No continuity from ignitor to
chassis.

Top surface
burner

Verify gas is supplied..................

Verify burner cap is positioned
correctly.

Check for obstructions in burner
ports.

L

A

B

A1

B1

N

Spark module
4 + 0

Test for voltage at terminals
L and N .......................................

Check polarity and ground..........

120 VAC

See wiring diagram

L

A

B

A1

B1

N

Spark module
4 + 0

Test for voltage at terminals
L and N .......................................

Check polarity and ground..........

120 VAC

See wiring diagram

Pressure regulator

Verify gas pressure (W.C.P.).

If on LP service verify proper gas
supply conversion.

4" or 5" Natural, see specifications
10" LP/propane

Power cord 3-wire

Verify resistance of wires to
terminals.

Continuity

Содержание AKS3040

Страница 1: ...C P 4 in W C P 5 in W C P LP Propane 10 in W C P 10 in W C P 10 in W C P 10 in W C P 10 in W C P Surface Burner BTU Nat LP Type of burner Sealed Sealed Sealed Sealed Sealed Right front 12 5 K 10 5 K 12 5 K 10 5 K 12 5 K 10 5 K 12 5 K 10 5 K 12 5 K 10 5 K Right rear 9 2 K 9 1 K 9 2 K 9 1 K 9 2 K 9 1 K 9 2 K 9 1 K 9 2 K 9 1 K Left front 9 2 K 9 1 K 9 2 K 9 1 K 9 2 K 9 1 K 9 2 K 9 1 K 9 2 K 9 1 K Lef...

Страница 2: ...Test for resistance of spark lead Test ignitor to chassis Continuity No continuity from ignitor to chassis Spark ignition electrode Test for resistance of spark lead Test ignitor to chassis Continuity No continuity from ignitor to chassis Top surface burner Verify gas is supplied Verify burner cap is positioned correctly Check for obstructions in burner ports L A B A1 B1 N Spark module 4 0 Test fo...

Страница 3: ...ve pin from cap 3 Apply downward finger pressure at the disc edges to place pin into the cap LP L P Natural NAT 4 Place pressure regulator cap on pressure regulator and tighten Low Flame Adjustment Properly adjusted burner flames are clean and blue with a distinct inner cone approximately inch long 1 Remove control knob from valve stem 2 Carefully remove rubber grommet from cooktop 3 Locate valve ...

Страница 4: ... power to oven before servicing unless testing requires power 16022195 Rev 0 March 2003 4 TOP BURNER IGNITION SWITCHES TOP IGNITORS SPARK MODULE N L BLK BLK BLK BLK TAN TAN TAN TAN TOP IGNITORS SPARK MODULE N L NEUTRAL LINE GROUND POWER CORD TOP BURNER IGNITION SWITCHES SCHEMATIC WIRING DIAGRAM 8104P828 60 ...

Отзывы: