Mayr 2/028.100.2 Скачать руководство пользователя страница 1

Installation and Operational Instructions for

 

ROBA

®

-brake-checker plus DC Type 028.100.2 

(B.0281002.EN)

28/06/2019 HH/GF/GC

Page 1 of 12

Chr. Mayr GmbH + Co. KG
Eichenstraße 1, D-87665 Mauerstetten, Germany
Tel.: +49 8341 804-0, Fax: +49 8341 804-421

www.mayr.com

, E-Mail: 

[email protected]

your reliable partner

Guidelines on the Declaration of Conformity

A conformity evaluation has been carried out for the product in terms of the EU Low Voltage Directive 2014/35/
EU, the Electromagnetic Compatibility (EMC) Directive 2014/30/EU and RoHS 2011 / 65 / EU with 2015 / 863 
EU. 
The Declaration of Conformity is laid out in writing in a separate document and can be requested if required.

Guidelines on the EMC Directive (2014/30/EU)

The product cannot be operated independently according to the EMC Directive. 
Only after integration of the product into an overall system can this be evaluated in terms of the EMC. 
For electronic equipment, the evaluation has been verified for the individual product in laboratory conditions, 
but not in the overall system.

Guidelines on the EU Directive 2011 / 65 / EU (RoHS II) with 2015 / 863 EU (RoHS III - from 22 

July 2019), 

which restrict the use of certain hazardous substances in electrical and electronic devices as well 

as in products / components (category 11), the proper operation of which is dependent on electric currents 
and electromagnetic fields.

Guidelines on the Machinery Directive (2006/42/EC)

The product is a component for installation into machines according to the Machinery Directive 2006/42/EC. 
The product can fulfil the specifications for safety-related applications in coordination with other elements. 
The type and scope of the required measures result from the machine risk analysis. 
The product then becomes a machine component and the machine manufacturer assesses the conformity 
of the safety device to the directive. It is forbidden to start use of the product until you have ensured that the 
machine accords with the regulations stated in the directive.

Guidelines on the ATEX Directive

Without a conformity evaluation, this product is not suitable for use in areas where there is a high danger 
of explosion. For application of this product in areas where there is a high danger of explosion, it must be 
classified and marked according to Directive 2014/34/EU.

Guidelines on the REACH Regulation (EC No. 1907/2006)

of the European Parliament and of the Council Concerning the Registration, Evaluation, Authorisation and Re-
striction of Chemicals. This regulates the manufacture, placing on the market and use of chemical substances 
in preparations, under certain conditions also pertaining to substances in products. 

mayr 

®

 power transmission 

exclusively manufactures products articles: clutches/couplings, electric motors, brakes and the appropriate 
rectifiers) in accordance with the definition in Article 3 Section 3 of the REACH Regulation.

11

Содержание 2/028.100.2

Страница 1: ...lectromagnetic fields Guidelines on the Machinery Directive 2006 42 EC The product is a component for installation into machines according to the Machinery Directive 2006 42 EC The product can fulfil...

Страница 2: ...short circuits and earth short circuits at the terminals Electronic devices cannot be guaranteed During the risk assessment required when designing the ma chine or system the dangers involved must be...

Страница 3: ...trol terminal 7 error output After a brake specific overexcitation time period the inte grated voltage reduction mechanism mode adjusts to the pre set holding voltage The voltage reduction mechanism m...

Страница 4: ...0 C Device ambient temperature C 25 to 70 25 to 60 Storage temperature C 40 to 105 Conformity markings Protection IP20 Installation conditions The installation position can be user defined Please ensu...

Страница 5: ...Electrical connection Power terminal 1 Supply voltage 24 VDC 48 VDC 2 Output voltage 3 Output voltage 4 Supply voltage 0 VDC Electrical connection Control terminal electrically isolated 1 Supply volta...

Страница 6: ...2 and 4 Here the ROBA brake checker monitoring module limits the switch off voltage to approx 60V DC side disconnection is signalized by the red light emitting di ode flashing at the moment of switch...

Страница 7: ...ys During detection and processing of different brake condi tions input and output signal delays can occur DIP switch Overexcitation time tO s 0 15 0 45 1 00 1 50 2 00 DIP switch Overexcitation time t...

Страница 8: ...N Operation with UH UN Type 2 028 100 2 overexcitation power reduction 45 C 75 C VDC VDC W 4 4 13 7 x 6 30 15 x x 8 53 27 x x 12 120 60 x x 16 270 135 x x 24 480 240 x 6 6 30 15 x 8 53 27 x x 12 120 6...

Страница 9: ...the switching frequency is higher than 1 cycle per minute or if the overexcitation time tO is longer than double the separation time t2 please observe the following P PN The coil capacity P must not b...

Страница 10: ...GF GC Page 10 of 12 Chr Mayr GmbH Co KG Eichenstra e 1 D 87665 Mauerstetten Germany Tel 49 8341 804 0 Fax 49 8341 804 421 www mayr com E Mail info mayr com your reliable partner Functional sequence di...

Страница 11: ...nd confirmed The products are designed for installation into electrical control cabinets and terminal boxes Using them for any other purpose is not allowed Disposal Electronic Components Products whic...

Страница 12: ...No signal output brake has audibly opened Release monitoring deactivated Activate release monitoring DIP setting Non specified brake brake worn brake does not release movement of the armature disk to...

Отзывы: