5. Timer operation 

 

Timer ON setting:   

-

  When the air-conditioner is OFF, press the “Timer” button and select a desired ON time through the 

temperature and time setting buttons.   

-

  “Preset ON Time” is displayed on the operation panel.   

-

  ON time can be regulated at any time in 0-24 hours.   

Timer OFF setting 

-

  When the air-conditioner ON, press “Timer” button and select a desired OFF time through the 

temperature and time setting buttons.   

-

  “Preset OFF Time” is displayed on the operation panel. 

-

  OFF time can be regulated at any time in 0-24 hours. 

6.Continuous Drainage 

Internal Tank Water Full Alarm Function 

The inner water tank in the air-conditioner has one water level safety switches, it controls the 
water level. When water level reaches an anticipated height, the water full indicator lights up. 
When the water is full, please remove the rubber blockage from the drainage hole at the bottom 
of unit, and drain all water outside. 
 

Continuous Drainage 

-

  When you plan to leave this unit unused for a long time, please remove the rubber blockage 

from the drainage hole at the bottom of unit, and drain all water outside. 

-

  You can use the continuous drainage with a drainage hose connected to the bottom drain hole, 

when the unit working at the HEAT mode. 

-

  The continuous drainage is not need to be applied when the unit working at the COOL or 

DEHUMIDIFY mode. The unit can evaporate the condensate water automatically by the 
splash motor. Make sure the drainage holes are stemmed well.   

-

  If water splash motor  is damaged, continuous drainage can be used. To connect the drain 

hose to the bottom drain hole (fig.9), the unit can also work well.   

-

  If splash motor is damaged, intermittent drainage can also be used. Under this condition, when 

the water full indicator lights up, please connect a drain hose to the bottom drainage hole, then 
all the water in the water tank will be drained outside. The unit can also work well. 

 

 

7. Installation Explanations

 

 
1.

 

Installation Explanations: 

 

-

  A removal air-conditioner shall be installed in the flat and empty place all around. Don’t block 

the air outlet, and the required distance around should be at least 30cm. (See Fig.8) 

-

  Should not be installed in dry cleaner.   

-

  Socket wiring should be in accordance with the local electric safety requirements.   

          
 

7. Installation Explanations

 

Содержание 20737

Страница 1: ...Portable Air Conditioner Model 20737 20738 User s Manual...

Страница 2: ...stallation Contents 1 Safety Awareness 1 2 Name of Parts 12 3 Accessories 12 4 Appearance and Function of Control Panel 13 5 Appearance and Function of Remote Control 13 6 Operation Introduction 14 7...

Страница 3: ...pliance or an operating electric heater Do not pierce or burn Be aware the refrigerants may not contain an odour Appliance shall be installed operated and stored in a room with a floor area larger tha...

Страница 4: ...fic evaluation recognized by associations in the industry Repairs must be performed based on the recommendation from the manufacturing company Maintenance and repairs that require the assistance of ot...

Страница 5: ...all not be made by children without supervision 13 The appliance shall be installed in accordance with national wiring regulations 14 Details of type and rating of fuses T 250V AC 2A or higher 15 Recy...

Страница 6: ...he person competent in the use of flammable refrigerants 22 Do not operate or stop the unit by inserting or pulling out Die power plug it may cause electric shock or fire due to heat generation 23 Unp...

Страница 7: ...der or CO 2 fire extinguisher adjacent to the charging area 1 6 No ignition sources No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contain...

Страница 8: ...to have an electrical supply to equipment during servicing then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation...

Страница 9: ...with inert gas open the circuit by cutting or brazing The refrigerant charge shall be recovered into the correct recovery cylinders The system shall be flushed with OFN to render the unit safe This pr...

Страница 10: ...bel shall be dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant 11 RECOVERY When removing refrigerant from a system either for servicin...

Страница 11: ...that leaking refrigerant may accumulate inside the enclosure and flammable atmosphere will be released when the enclosure is opened Ventilated enclosure see Clause GG 4 Safety of the appliance depend...

Страница 12: ...before putting into service d Decommissioning If the safety is affected when the equipment is putted out of service the refrigerant charge shall be removed before decommissioning Ensure sufficient ve...

Страница 13: ...l required signs are to be maintained and employers should ensure that employees receive suitable and sufficient instruction and training on the meaning of appropriate safety signs and the actions tha...

Страница 14: ...essories are included and check their purposes in the installation introduction in this manual Part Description Quantity Main Air conditioner Unit 1 Hot air exhaust hose 1 Hose Connector Window end 1...

Страница 15: ...ly model 5 Appearance and Function of Remote Control 4 Appearance and Function of Control Panel 5 Appearance and Function of Remote Control Fan speed selector Mode selector Hourly programming Temperat...

Страница 16: ...sed to direct sunlight 6 Operation Introduction Before starting operations in this section 1 Find a place where there is power supply nearby 2 As shown in Fig 6 and Fig 6a install the exhaust hose and...

Страница 17: ...rements The socket is for AC use Do not share one socket with other appliances Power supply is AC220 240V 50Hz 2 Cooling operation Press the Mode button till the Cool icon appears Press the or button...

Страница 18: ...ainage hole at the bottom of unit and drain all water outside You can use the continuous drainage with a drainage hose connected to the bottom drain hole when the unit working at the HEAT mode The con...

Страница 19: ...xing clip and the flat fixing clip 2 Insert the square fixing clip into openings at back of the air conditioner see Fig 9 3 Put the other end of the exhaust hose to the near windowsill Window Slider K...

Страница 20: ...ll indicator lamp lights up If water pump is damaged when the water is full please remove the rubber blockage at the bottom of unit and all water will drain outside 8 Maintenance Explanations Declarat...

Страница 21: ...p in the shade Mounting Putting the air filter into the inlet grille replace the components as they were 2 Clean the Air conditioner Surface First clean the surface with a neutral detergent and wet cl...

Страница 22: ...ed Connect or clean the exhaust air hose Temperature setting is too high Reset the temperature Air inlet is blocked Clean the air inlet 3 Noisy The ground is not level or not flat enough Place the uni...

Страница 23: ...21 6 E3 Code Evaporator temperature sensor failed Replace evaporator temperature sensor 7 E4 Code Water tank full when heating Please empty the water tank Note The real products may look different...

Страница 24: ...rdelen en handleidingen Heb je vragen of klachten contacteer ons en we helpen je graag verder NOTRE EQUIPE MAXXTOOLS VOUS AIDERA VOLONTI RE AUX CAS SUIVANTS n Questions sur votre commande n R clamatio...

Отзывы: