5.4  Turn-on Fan 

Once your cooling pads are saturated with water – you may turn your MaxxAir unit on high. Now you can begin to feel the 

MaxxAir difference in temperature. After your MaxxAir has run for 5 minutes or so, visually inspect the pads – if water is 

dripping outside the unit – gently adjust pads at the bottom to stop water flowing outside the unit.  

 

6.0  Daily Operating procedures 

6.1  Turn-on water pump 

Turn on water pump to unit – turn fan on low – let cooling pads get saturated – then turn fan on high for cooling.  

You must determine what works best for you and your specific environment. 

 

6.2  Turn fan on high 

When you can see that the cooling pads are saturated with water – turn the fan on high and feel the cooler air coming from  

your MaxxAir unit. Adjust the fan speed for your comfort. 

 

6.3  Turn-off unit at end of day 

15 minutes before closing for the day – (1.) Turn off water pump with toggle switch – (2.) Leave fan running – this action 

will shut-off water to the cooling pads while keeping the fan running. The fan will dry out the cooling pads. (3.) When the 

cooling pads are thoroughly dry – turn off fan. 

Drying your cooling pads thoroughly - everyday will help prevent mold 

and mildew growth, plus it will prolong the life of your cooling pads.

 

 

7.0  Maintenance  

7.1  Access inside of unit 

Turn-off water pump and let the fan continue to run until the cooling pads are thoroughly dry (about 10 – 15 minutes). Once 

your cooling pads are completely dry you may turn-off fan. Now unplug electricity to unit to avoid unnecessary shock. Next, 

using a 7/16” wrench – remove the two retaining bolts from the backside and topside (cooling pad side) of the unit. These 

two bolts hold the thick metal angle retaining bar and the cooling pads in place. Next, remove the angle retaining bar and set 

to side. Now you are ready to remove your unit’s cooling pads. 

 

7.2  Removing the cooling pads 

Before your start, make a note of the direction of the angle of the pads flutes 

(see side of  

pads).

 You must put pads back in correct order for your unit to function effectively.  

(Note: Install steep side 45° angle flute to the back of unit - see photo for verification.)  

Once the retaining angle bar is removed from the top of your MaxxAir unit, reach to the top of

 

the dry cooling pad to the left and gently take hold of the top of the pad and gently pull down  

and back – this action will loosen the pad from the unit. Look at the direction of the angle of the  

pad flutes 

(side of pads

). Remove the cooling pad and proceed to the next pad. Then, remove all cooling pads and gently set 

in a safe place. Note: this is a good time to take the cooling deck pads outside and run clean water over the pads to remove 

any  accumulated  dirt  and  debris. 

Do  not  use  high  pressure  hose

  –  this  will  damage  pads  and  their  ability  to  function 

effectively. Make sure the pads are thoroughly dry before placing back inside the unit.  

 

Содержание EC18DVS

Страница 1: ...s manual in a safe place for future reference It contains operating procedures maintenance procedures trouble shooting guide replacement parts guide order form and contact information You will need t...

Страница 2: ...t is strongly recommended WARNING Check your units electric power cord for insulation breaks cracks or fraying If any of these conditions are found DO NOT USE See your distributor for immediate servic...

Страница 3: ...reservoir with water 5 2 Turn on pump 5 3 Turn on Fan 6 0 Daily Operating procedures 6 1 Turn on pump 6 2 Turn on fan 6 3 Turn off unit 7 0 Maintenance 7 1 Access inside of unit 7 2 Removing the cooli...

Страница 4: ...nd that regular fans only circulate same temperature air same humidity your MaxxAir portable evaporative cooler takes that same existing air combines it with evaporating water which dramatically lower...

Страница 5: ...r with water Once your water hose is connected turn water on and fill the reservoir with water Listen carefully You can hear water filling the reservoir Check your water connection make sure there is...

Страница 6: ...to run until the cooling pads are thoroughly dry about 10 15 minutes Once your cooling pads are completely dry you may turn off fan Now unplug electricity to unit to avoid unnecessary shock Next using...