Service and Installation Manual
6
OPERATION
CAUTION
Do not throw items into the storage area.
Failure to heed these recommendations
could result in damage to the interior of the cabinet.
Refrigerated cabinets
Temperature range for the internal cabinets is 35°to 40°F for all undercounter refrigerators.
Continual frequent opening and closing of the appliance door may prevent the unit’s ability to maintain
optimum refrigeration temperature.
Proper programming or set up of the unit automatic defrost cycle will keep the evaporator from becoming
frozen and allow the fans to properly circulate cooling air throughout the storage compartment.
Defrosting:
The factory default setting should be such that every 6 hours, the unit will turn off so the evaporator coil can
defrost.
The controller now displays the defrost symbol.
When the coil temperature reaches the terminal
temperature or after 20 minutes of defrost, the unit will turn on.
SOLID-STATE THERMOSTAT DESCRIPTIONS
1.
FRONT PANEL COMMANDS
To display target set point; in programming mode it selects a parameter or confirm an operation.
To start a manual defrost.
In programming mode it browses the parameter codes or increases the displayed value.
In programming mode it browses the parameter codes or decreases the displayed value.
KEY COMBINATIONS
To lock or unlock the keyboard.
To enter in programming mode.
To return to room temperature display.