Service and Installation Manual

 

INSTALLATION                                                                                                                                     

Location 

Units represented in this manual are intended for indoor use only. Be sure the location chosen has a floor 
strong enough to support the total weight of the cabinet and contents. A fully loaded unit can weigh as much 
as 1500 pounds. Reinforce the floor as necessary to provide for maximum loading. For the most efficient 
refrigeration, be sure to provide good air circulation inside and out

.

 

 
Inside cabinet: 

Do not pack the units so full that air cannot circulate. The refrigerated air is discharged at the top rear of the 

unit. It is important to allow for proper air flow from the top rear to the bottom of the unit. Obstructions to this 

air flow can cause evaporator coil freeze ups and loss of temperature or overflow of water from the 

evaporator drain pan. The shelves have a rear turn up on them to prevent this. However, bags and other 

items can still be located to the far rear of the cabinet. 

Air is brought into the evaporator coil with fans mounted 

to the front of the coil.   

 

Outside cabinet:

   

Be sure that the unit has access to ample air. Avoid hot corners and locations near stoves and ovens. 
It is recommended that the unit be installed no closer than 2" from any wall with at least 12" of clear space above 
the unit. 

Leveling 

A level cabinet looks better and will perform better because the doors will line up with the frames properly.    Use 
a level to make sure the unit is level from front to back and side to side. Units supplied with legs will have 
adjustable bullet feet to make the necessary adjustments. If the unit is supplied with casters, no adjustments are 
available. Ensure the floor where the unit is to be located is level. 

 
Stabilizing 

All models are supplied with casters for your convenience, ease of cleaning underneath and for mobility. It is 
very important, however, that the cabinet be installed in a stable condition with the front wheels locked while in 
use. 
Should it become necessary to lay the unit on its side or back for any reason, allow at least 24 hours before 
start-up to allow compressor oil to flow back into place. Failure to meet this requirement can cause 
compressor failure and unit damage. 

 
 

Unit repairs will not be subject to standard unit warranties if due to improper installation 

procedures. 

 

Electrical connection

 

Refer to the amperage data on page 3, the serial tag, your local code or the National Electrical Code to be sure 
the unit is connected to the proper power source.   
 

 

The unit must be turned OFF and disconnected from the power source whenever 
performing service, maintenance functions or cleaning the refrigerated area. 

 

 

 

 

Содержание MXX-23F

Страница 1: ...and Care Manual Please read this manual completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately See page 2 IMPORTANT INFORMATION R...

Страница 2: ...ken during unloading so the equipment is not damaged while being moved into the building 1 Visually inspect the exterior of the package and skid or container Any damage should be noted and reported to...

Страница 3: ...stallation Manual 3 SPECIFICATION MODEL V Hz Ph AMPS STORAGE CAPACITY Cu ft HP BTU H CHARGE OZ SHIP WEIGHT LBS NEMA PLUG MXX 23R 115 60 1 4 25 1 4 830 11 99 232 5 15P MXX 23F 115 60 1 7 25 3 4 1966 10...

Страница 4: ...han 2 from any wall with at least 12 of clear space above the unit Leveling A level cabinet looks better and will perform better because the doors will line up with the frames properly Use a level to...

Страница 5: ...l also keep running during when door is open but cycle off during a defrost period The door switch will activate the lights when opened 1 Every 6 hours the unit will turn off and electric heater will...

Страница 6: ...MANUAL DEFFROST Hold the key for more than 2 seconds and the manual defrost will start 2 4 HOW TO LOCK THE KEYBOARD 1 Hold the and keys for more than 3s 2 The POF message will be displayed and the ke...

Страница 7: ...condenser coil can initially cause high temperatures and excessive run times Continuous operation with dirty or clogged condenser coils can result in compressor failures Neglecting the condenser coil...

Страница 8: ...come brittle and prevent proper seals Do not use sharp tools or knives to scrape or clean the gasket which could possibly tear the gasket and rip the bellows Gaskets can easily be replaced and don t r...

Страница 9: ...Service and Installation Manual 9 WIRING DIAGRAM MODEL MXX 23R MODEL MXX 23F...

Страница 10: ...Service and Installation Manual 10 WIRING DIAGRAM MODEL MXX 23R...

Страница 11: ...Service and Installation Manual 11 WIRING DIAGRAM MODEL MXX 23F...

Отзывы: