Maxx Cold MXSPP50 Скачать руководство пользователя страница 6

Page 

6

 of 

19

 

 

IMPORTANT SAFEGUARDS (cont.) 

Electrical Connection 

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, 
this appliance must be properly grounded.  The power cord of this appliance is equipped with a 3-prong grounding 
plug that mates with a standard 3-prong grounding wall outlet to minimize the possibility of electric shock hazard from 
the appliance. Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly 
grounded. The 

appliance

 should always be plugged into its own individual electrical outlet which has a voltage rating 

that matches the rating label on the appliance. This provides the best performance and also prevents overloading 
house wiring circuits which could cause a fire hazard from overheated wires. Repair or replace immediately all power 
cords that have become frayed or otherwise damaged. Do not use a cord that shows cracks or abrasion damage along 
its length or at either end. When moving the 

appliance

, be careful not to damage the power cord. 

 

Refrigerant Disposal 

If you are throwing away your old appliance it may have a cooling system that uses “Ozone Depleting” chemicals. Make 
sure the refrigerant is removed for proper legal disposal by a qualified service technician.

 

 

 

Содержание MXSPP50

Страница 1: ...SERVICE please contact 1 877 368 2797 Service MaxxHelp com 3355 Enterprise Avenue Suite 160 Fort Lauderdale FL 33331 USA Phone 954 202 7419 Website MaxximumFoodService com MXSPP50 w 1 DOOR MXSPP70 w 2...

Страница 2: ...tside cabinet 10 Installation Clearance 11 Leveling 11 Stabilizing 11 Electrical Connection 11 OPERATION 12 Refrigerated cycle 12 Power Switch 12 SOLID STATE THERMOSTAT DESCRIPTIONS 12 1 FRONT PANEL C...

Страница 3: ..._________________________________ MODEL ________________________________________ DATE OF PURCHASE _______________________________ SERIAL NUMBER INFORMATION l The serial number of all self contained re...

Страница 4: ...ION means that failure to heed this safety statement may result in minor or moderate personal injury or property or equipment damage All safety messages will alert you to what the potential hazard is...

Страница 5: ...g or servicing Failure to do so can result in electrical shock or death If the unit is not in use for a long period of time best to unplug the unit from the outlet After unplugging the unit wait at le...

Страница 6: ...always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating label on the appliance This provides the best performance and also prevents overloading h...

Страница 7: ...Interior Dimensions W D H 650 x 707 x 672 1245 x 707 x 672 1840 x 707 x 672 Nominal Capacity 10 95 Cu Ft 310 L 20 91 Cu Ft 592 L 30 87 Cu Ft 874 L Appliance Weight 201 lb 91 kg 342 lb 155 kg 485 lb 22...

Страница 8: ...using and visually inspect the refrigeration package Be sure lines are secure and base is still intact 6 Freight carriers can supply the necessary damage forms upon request 7 Retain all crating materi...

Страница 9: ...IGHT REFRIGERATOR SOLID DOOR LEFT REFRIGERATOR SOLID DOOR CASTERS MXSPP92 THERMOSTAT CONTROL PANEL REFRIGERATOR SOLID DOOR CENTER REFRIGERATOR SOLID DOOR LEFT REFRIGERATOR SOLID DOOR RIGHT POWER SWITC...

Страница 10: ...binet and contents as a fully loaded unit can weigh as much as 800 pounds Reinforce the floor as necessary to provide for maximum loading For the most efficient refrigeration be sure to provide good a...

Страница 11: ...and unit damage which would not covered by your warranty NOTICE Unit repairs will not be subject to standard unit warranties if due to improper installation procedures Electrical Connection Refer to...

Страница 12: ...2 Anti condensation heaters on door frames work in conjunction with the compressor 3 Recommended holding temperature range 34 to 40 F 2 to 5 C 4 Comes factory set to 39 F 4 C Power Switch The power sw...

Страница 13: ...y for more than 2 seconds and a manual defrost will start 2 4 TO LOCK THE KEYBOARD 1 Keep pressed for more than 3s the and keys 2 The OF message will be displayed and the keyboard will be locked If a...

Страница 14: ...on use and specifically for the condenser coils The condenser coil may require cleaning with the de greasing agent and then blown through with compressed air Failure to maintain a clean condenser coil...

Страница 15: ...passivity of the steel CAUTION Never use an acid based cleaning solution Many food products have an acidic content which can deteriorate the finish Be sure to clean the stainless steel surfaces of all...

Страница 16: ...at to lower temperature Cabinet Temperature is too Warm Thermostat is set too high Set thermostat to lower temperature Airflow is blocked Re arrange products to allow for proper air flow Make sure the...

Страница 17: ...Page 17 of 19 WIRING DIAGRAMS MXSPP50...

Страница 18: ...Page 18 of 19 WIRING DIAGRAMS cont MXSPP70...

Страница 19: ...Page 19 of 19 WIRING DIAGRAMS cont MXSPP92...

Отзывы: