3 Maintenance
Replacing a Disk
A disk failure is indicated when the Power/Error LED at the front of the drive tray turns red and
the audible alert sounds.
The LCD panel displays the failure with the symbol “R” or “W”. “R” indicates a disk failure or
error, and “W” indicates that there are too many bad sectors on the disk.
Disks are hot swappable, which means that they can be inserted and removed while the disk array
system is powered on and operating. Follow these instructions to replace a failed disk.
1
Unlock the disk tray with an included disk tray key.
2
Gently pull the disk tray handle to the opened position.
3
Remove the screws from the failed disk, then remove the disk from the disk tray.
4
Align the rear of the new disk with the rear of the disk tray.
5
Insert the new disk into the disk tray.
6
Attach the disk to the disk tray with the screws that came with the disk.
7
Slide the disk tray back into the empty slot, then close the disk tray handle.
8
Lock the disk tray with the key.
Note
Turn off the audible alert by pressing the Up and Down function but-
tons on the front panel twice simultaneously.
Note
The new disk must have the same or a greater capacity than the
faulty disk that was removed. If the disk capacity is smaller, the
audible alert sounds and the auto-rebuild operation doesn’t start.
For best performance, it is recommended that the new disk be
identical to the failed disk.
1 1 2 2 2 2 W R
Example:
• Disks 1 to 2 are members of RAID group 1.
• Disks 3 to 6 are members of RAID group 2.
• Disk 7 has too many bad sectors.
• Disk 8 has an error or a fault.
Содержание Sivy SA-3340S
Страница 1: ...Ultra 320 SCSI to Serial ATA Disk Array Systems Version 1 0 Sivy SA 3340S Hardware User Manual...
Страница 2: ......
Страница 3: ...ESC Enter SA 3340S Ultra 320 SCSI to Serial ATA Disk Array System Hardware User Manual...
Страница 4: ......
Страница 6: ......
Страница 32: ...22 SA 3340S Serial ATA Disk Array Systems 3 Maintenance Replacing a Fan...