5-106
Maxtor Atlas 10K V
5.27
RECEIVE DIAGNOSTIC RESULTS Command (1Ch)
The RECEIVE DIAGNOSTIC RESULTS command fetches the results of the last
SEND DIAGNOSTIC command sent to the drive. The drives support the diagnostic
pages listed in Table 5-149.
Table 5-149
Diagnostic Pages Supported by The Drives
The RECEIVE DIAGNOSTIC RESULTS Command Descriptor Block is shown in
Table 5-150; the data fields are described in Table 5-151.
To receive one or both of the two diagnostic pages that are available, the initiator first
sends the desired page code(s) to the drive using a SEND DIAGNOSTICS command.
The SEND DIAGNOSTICS command tells the drive which page it should return in
response to the next RECEIVE DIAGNOSTICS RESULTS command. The page
specified in the most recent SEND DIAGNOSTICS command is always the page
returned in response to the RECEIVE DIAGNOSTICS RESULTS command.
Table 5-150
RECEIVE DIAGNOSTIC RESULTS Command Descriptor Block-Data Format
Table 5-151
RECEIVE DIAGNOSTIC RESULTS Command Descriptor Block-Field Descriptions
Page
Code
Description
Size In Bytes
00h
Supported Diagnostic Pages
6
40h
Translate Address Page (SEND DIAG)
14
40h
Translate Address Page (RECEIVE DIAG)
14 or more
Bit
Byte
7
6
5
4
3
2
1
0
0
Operation Code (1Ch)
1 Reserved
PCV
2
Page Code Value
3 - 4
Allocation Length
5
Reserved
Control
Field
Description
Allocation
Length
Specifies the number of bytes of diagnostic-page results the drive is allowed to send to the
initiator. A CHECK CONDITION is not returned if this value truncates the information
available.
Содержание Atlas 10K V
Страница 1: ...Maxtor Atlas 10K V Product Manual September 6 2005 Revision 3 PN 000001911...
Страница 39: ...Maxtor Atlas 10K V 3 15...
Страница 48: ...3 24 Maxtor Atlas 10K V Figure 3 9 Crosswise Airflow Cooling Below Unit Above Unit...
Страница 125: ...Maxtor Atlas 10K V 5 67 21 23 Reserved...
Страница 147: ...Maxtor Atlas 10K V 5 89 22 23 MSB Extent Length LSB...
Страница 214: ...5 156 Maxtor Atlas 10K V...