![Maxtor 96147H6 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/maxtor/96147h6/96147h6_user-manual_1745900028.webp)
AT INTERFACE DESCRIPTION
5 – 3
T IM IN G PARAMET ERS
MODE 0
MODE 1
MODE 2
MODE 3
MODE 4
t0
Cycle Time ( min )
60 0 ns
38 3 ns
24 0 ns
18 0 ns
12 0 ns
t1
Ad dress vali d to DIOR-/D IOW - setup ( min)
70 ns
50 ns
30 ns
30 ns
25 ns
t2
D IOR- /DIOW- 16 -bi t ( min)
16 5 ns
12 5 ns
10 0 ns
80 ns
70 ns
t2 i
D IOR-/DIOW- re cover y ti me ( min )
70 ns
25 ns
t3
DIOW- data se tup ( min )
60 ns
45 ns
30 ns
30 ns
20 ns
t4
DIOW- da ta hold ( min)
30 ns
20 ns
15 ns
10 ns
10 ns
t5
D IOR- d ata setup ( min)
50 ns
35 ns
20 ns
20 ns
20 ns
t6
DIOW- da ta hold ( min)
5 ns
5 ns
5 ns
5 ns
5 ns
t6Z
D IOR- d ata tri state (max)
30 ns
30 ns
30 ns
30 ns
30 ns
t9
D IOR-/DIOW- to address va li d hold ( min )
20 ns
15 ns
10 ns
10 ns
10 ns
tRd
Re ad Data Va li d to IORDY a cti ve ( min )
0
0
0
0
0
tA
IORD Y Setup Ti me
35 ns
35 ns
35 ns
35 ns
35 ns
tB
IORDY Pulse Width (max)
12 50 ns
12 50 ns
12 50 ns
12 50 ns
12 50 ns
PIO Timing
PIO Timing
PIO Timing
PIO Timing
PIO Timing
Figure 5 - 2
PIO Data Transfer To/From Device
Содержание 96147H6
Страница 2: ...Revisions ManualNo 1495...