background image

External power 

supply

12VDC(15%), 80mA

Memory backup

EEPROM(overwrites: 100,000 times min.)that can store data for 10 

years min.

Ambient 

temperature

Operating: -10 to 55°C(with no icing or condensation)

Storage: -25 to 65°C(with no icing or condensation)

Ambient humidity 25% to 85%

MTC  Series

Timer/Counter/Tachometer operation manual

3、

Model Number Legend

4、

Electric Specifications

Parameter name

Timer

Counter/Tachometer

Rated supply 

voltage

100~240VAC(50/60HZ), 24VAC(50/60HZ), 24VDC(permissible 

ripple: 20%(p-p)max.)

Operating voltage 

range

85% to 110% rated supply voltage(24VDC; 90% to 110%)

Power consumption Approx. 6.2VA at 264VAC, Approx. 5.1VA at 26.4VAC, 

Approx. 2.4W at 24VDC

Input signals

Signal, reset, gate

CP1, CP2, Reset 1, Reset 2

Input method

No-voltage input/voltage input (switchable)

No-voltage input

ON impedance: 1kΩ max.(leakage current: 5~20 mA when 0Ω(

ON residual voltage: 3V max.

OFF impedance: 100kΩ min.

Voltage Input

High(logic) level: 4.5 to 30 VDC

Low(logic) level: 0 to 2 VDC

(Input resistance: approx. 4.7 kΩ)


Reset input

Minimum input signal width: 1/20 ms(selectable, same for all input)

Sensor waiting time 250 ms max.(control output is turned OFF and no input is accepted 

during sensor waiting time)

Output method

Relay/transistor output

Control output

SPDT contact output: 5A at 250 VAC, resistive load(cos

Ф

=1)

Minimum applied load: 10 mA at 5 VDC(failure level: P, reference 

value)

Transistor output: NPN open collector, max. 100mA at 30 VDC

Residual voltage: 1.5 VDC max.(approx. 1V)

Output category according to EN60947-5-1 for timers with Contact 

outputs

(AC-15; 250V 3A / AC-13; 250V 5A / DC-13; 30V 0.5A)

Output  category  according  to  EN60947-5-2  for  timers  with 

Transistor outputs

(DC-13; 30V 100 mA)

NEMA B300 Pilot Duty, 1/4 HP 5-A resistive load at 120 VAC, 1/3 

HP 5-A resistive load at 240 VAC

Parameter name Parameter

Setting range (use   key to select)

Default value

Time range

--.--s/---.-s/----s/--min:--s/---.-min/

----min/--h:--min/---.-h/----h/-.---s

--.--s

Timer mode

up/down

up

Output mode

a/a-1/a-2/a-3/b/b-1/d/e/f/z

a

Output time

hold/0000.01~9999.99

hold

Input signal width

20ms/1ms

20ms

NPN/PNP input 

mode

npn/pnp

npn

Key protection 

level

kp-1/kp-2/kp-3/kp-4/kp-5

kp-1

Twin Timer parameter setting

Run mode

Power ON

Function

setting mode

PV/OFF set time

PV/ON set time

OFF time range

ON time range

Timer mode

ON/OFF start mode

Input signal width

NPN/PNP input mode

Key protection level

3s min.

MODE

MODE

MODE

MODE

MODE

MODE

MODE

MODE

MODE

Parameter name Parameter

Setting range (use   key to select)

Default value

OFF time range

--.--s/---.-s/----s/--min:--s/---.-min/

----min/--h:--min/---.-h/----h/-.---s

--.--s

ON time range

--.--s/---.-s/----s/--min:--s/---.-min/

----min/--h--min/---.-h/----h/-.---s

--.--s

Timer mode

up/down

up

ON/OFF start 

mode

toff/ton

toff

Input signal width

20ms/1ms

20ms

NPN/PNP input 

mode

npn/pnp

npn

Key protection 

level

kp-1/kp-2/kp-3/kp-4/kp-5

kp-1

2-Stage Timer parameter setting

Power ON

Run mode

Absolute value

Forecast value

Set value 1

Set value 2

Forecast set value

Set value 

3s min.

Function

setting mode

Forecast/absolute value

Time range

Output mode

Input signal width

NPN/PNP input mode

Key protection level

Parameter name Parameter

Setting range (use   key to select )

Default value

Forecast/

absolute value

ofst/abs

ofst

Time range

--.--s/---.-s/----s/--min--s/---.-min/

----min/--h--min/---.-h/----h/-.---s

--.--s

Output mode

a/f-1

a

Input signal width

20ms/1ms

20ms

NPN/PNP input 

mode

npn/pnp

npn

Key protection 

level

kp-1/kp-2/kp-3/kp-4/kp-5

kp-1

Time parameter setting

Mode setting

1、

Safety Precautions

Do not use the product where corrosive or volatile gases are present, there may 

occasionally be a risk of explosion.

Usable life of output relay is determined by switch condition. According the actual 

usage, use product within its rated load and electrical life expectancy. If using product 

beyond its life expectancy, its contacts may become fused or there may be a risk of 

fire.

This may occasionally cause electric shock, fire or malfunction. Never disassemble, 

repair or modify the product.

This may occasionally cause electric shock, fire or malfunction. Do not allow metal 

fragments or lead wire scraps to fall inside this product. 

Make sure that the supply voltage and signal connection is correct before power is 

supplied, otherwise the product may be damaged.

Do not touch the input terminals or repair the product while power is supplied.This may 

cause electric shock.

1.

2.

3.

4.

5.

6.

2、

Nomenclature

5、

Function parameter setting

1-stage counter

2-stage counter

Total counter

Run mode

Power ON

3s min.

Key protect switch

3s min.

3s min.

Transmission speed

Parity check

Date bit

Stop bit

Station address

Communication on/off

MODE

MODE

MODE

MODE

MODE

MODE

Batch counter

Dual counter

Tachometer

Twin timer

2-stage timer

Timer

  

★ 

Timer/ Counter/ Tachometer Selection Mode

Parameter name

Parameter

Setting range

Default value

Timer/Twin Timer/2-Stage Timer 

Selection Mode

/

/

tim

1-stage/ 2-stage / Total /Batch 

/ Dual counter / Tachometer 

Selection Mode

/

/
/

/

1cnt

  

★ 

Communication Format Function Selection Mode

Parameter name Parameter

Setting range (use   key to select)

Default value

Transmission 

speed

1200, 2400, 4800, 9600, 14400, 19200, 

28800, 38400, 57600bps

9600

Parity check

NONE/ODD/EVEN

none

Date bit

8-bit/7-bit

8-bit

Stop bit

1-bit/2-bit

1-bit

Station address

01~FF (HEX)

01

Communication 

on/off

ON/OFF

on

  

★ 

Key Protection Setting Mode

Parameter name Parameter

Setting range (use   key to select)

Default value

Key protection 

switch

off/on

off

Timer parameter setting

Run mode

Power ON

Function

setting mode

PV/SV

PV/ON duty ratio

PV/cycle

Time range

Timer mode

Output mode

Output time

Input signal width

NPN/PNP input mode

Key protection level

3s min.

Timer (except for Z mode)

MODE

MODE

MODE

MODE

MODE

MODE

MODE

MODE

MODE

Timer (Z mode)

Counter parameter setting

Function setting 

mode

Run mode

Power ON

Present value,

 set value 1 

Present value, 

set value 2

3s min.

1-stage counter

Present value 

set value 

2-stage counter

CP1 present value

CP2 present value

MODE

Dual counter

Dual count value, 

dual count set value

Input mode

Dual count calculating mode

Output mode

One-shot output time

One-shot output 2 time

One-shot output 1 time

MODE

MODE

MODE

MODE

MODE

MODE

Counting speed

Input signal width

Decimal point position

Prescale value

NPN/PNP input mode

Key protection level

MODE

MODE

MODE

MODE

MODE

Present value,

set value

Total set value

MODE

Total and preset counter

Present value, 

set value

Batch count value,

batch count set value

Batch counter

MODE

MODE

MODE

Tachometer parameter setting

Function setting 

mode

Run mode

Power ON

3s min.

Tachometer output mode

Counting speed

Decimal point position

Prescale value

Average processing

Auto-zero time

MODE

MODE

MODE

MODE

MODE

MODE

Startup time

Measurement value

Measurement value

OUT1 set value

NPN/PNP input mode

Key protection level

MODE

MODE

MODE

MODE

MODE

Measurement value

OUT2 set value

MODE

Parameter name Parameter

Setting range (use   key to select)

Default value

Input mode

up/down/ud-a/ud-b/ud-c (See note 1.)

up

Dual count 

calculating mode

add/sub (See note 1.)

add

Output mode

n/f/c/r/k-1/p/q/a/k-2/d/l/h (See note 2.)

n

One-shot output 

time

000.001~999.999

000.500

One-shot output 

2 time

000.001~999.999

000.500

One-shot output 

1 time

hold/000.001~999.99 (See note 3.)

hold

Counting speed

30Hz/5KHz

30hz

Input signal width

20ms/1ms

20ms

Decimal point 

position

----/---.-/--.--/-.---

----

Prescale value

000.001~999.999

001.000

NPN/PNP Input 

mode

NPN/PNP

NPN

Key protection 

level

kp-1/kp-2/kp-3/kp-4/kp-5

kp-1

Note:   1.The setting range varies with the output mode.

            2.The setting range varies with the model and the input mode.

            3.HOLD can not be set when the output mode is K-2.

Setting range

Unit

Default value

0000.00~9999.99 (Time range: -.-s)

s

0000.00

00000.0 ~ 99999.9 (Time range: -.-s)

s

00000.0

000000 ~ 999999 (Time range: --s)

s

000000

0000:00 ~ 9999:59 (Time range: -min-s)

min:s

0000:00

00000.0 ~ 99999.9 (Time range: -.-min)

min

00000.0

000000 ~ 999999 (Time range: --min) 

min

000000

0000:00 ~ 9999:59 (Time range: -h-min)

h:min

0000:00

00000.0 ~ 99999.9 (Time range: -.-h)

h

00000.0

000000 ~ 999999 (Time range: --h)

h

000000

000.000 ~ 999.999 (Time range: -.-s)

s

000.000

Set Value (Range) A, B 

Display

Key Protection Indicator

Mode Key

(changes modes and 

setting items)

Reset Key 

(resets present value and 

output)

Reset Indicator

Control Output Indicator

Set Value 

(character height: 4 mm)

Present Value 

(character height: 9 mm)

Time Unit Display 

(If the time range is 

0min, 0.0 min, 0h,0.0h, 

0 h : 0 m ,   t h i s   d i s p l a y 

flashes to indicate timing 

operation)

The Fifth Setting Key

The Fourth Setting Key

The Sixth Setting Key

The Second Setting Key

The Third Setting Key

The First Setting Key

MTC  –  3  1  2  1  –  A

   A         B  C  D  E      F

A.Maxtech

Timer / Conuter/ Tachomer

B.Functions: 3

Timer / Conuter/ Tachomer all in 1 

C

.

Output type: 1-Relay    2-Transistor 

D.Communiction: 1-No Communiction    2-RS-232    3-RS-422    4-RS-485

E.Installation: 1-DIN rail   2-48x48mm panel 

F.Voltage

A-AC100~240V, 50/60 Hz    D- DC24V / AC24V