background image

19

The FCC also requires the transmitter of a FAX transmission be
properly identified (per FCC Rules Part 68, Sec. 68.381 (c) (3)).

FCC Class B Statement

 This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protec-
tion against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio fre-
quency energy, and if not installed and used in accordance with
the instructions, may cause harmful interference to radio com-
munications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one
or more of the following measures:

    • Reorient or relocate the receiving antenna
  • Increase the separation between the equipment and the

receiver

  • Connect the equipment into an outlet on a circuit different

from that to which the receiver is connected

    • Consult the dealer or an experienced radio / TV technician for

help

Notice:  1) Shielded cables, if any, must be used in order to
comply with the emission limits. 2) Any change or modification
not expressly approved by the Grantee of the equipment
authorization could void the user’s authority to operate the
equipment.

DOC Compliance Information

NOTICE: The Canadian Department of Communications label
identifies certified equipment. This certification means that the
equipment meets certain telecommunications network protec-
tive, operational and safety requirements. The Department
does not guarantee the equipment will operate to the user’s
satisfaction.

Before installing this equipment, users ensure that it is permis-
sible to be connected to the facilities of the local telecommuni-
cations company. The equipment must also be installed using
an acceptable method of connection. The customer should be
aware that compliance with the above conditions may not
prevent degradation of service in some situations.

Repairs to certified equipment should be made by an authorized
Canadian maintenance facility designated by the supplier. Any
repairs or alterations made by the user to this equipment, or
equipment malfunctions, may give the telecommunications

Содержание SF-1128HV/R16-PnP

Страница 1: ...Part MAN080 Rev 1 0 SF 1128HV R16 PnP High Performance V 34 V 42bis 28 800 BPS Internal Plug and Play FAX Voice Data Modem Featuring Advanced Full Duplex Speakerphone Functions User s Manual...

Страница 2: ...time of this manual s production The manufacturer reserves the right to make any changes and improvements in the product de scribed in this manual at any time and without notice Consequently the manu...

Страница 3: ...provide step by step instructions on how to install your new 28 8 Kbps FAX Voice Data modem Installation of this modem product is a three stepprocessconsistsof1 actualhardwareinstallation 2 plug and p...

Страница 4: ...uipment Turn off and unplug your PC before installation Dis charge any static electricity from your body by touching any bare metal surface of the PC system such as its power supply cover 1 Turnoffand...

Страница 5: ...ed to determine which addresses andinterruptstouseforeachdevice ConsultyourPC s owner s manual to determine if it is PnP Revision 1 0a compliant YoumostlikelyhaveaPlugandPlayRevision 1 0a compliant sy...

Страница 6: ...ms selectingthemodemandclickingon Properties under the General tab Note which COM port is being used by the modem Proceed to Section 2 5 Software Installation Configuration 2 4 2 ConfiguringinaPlugand...

Страница 7: ...r Generic Class 1 modem type should be selected in your fax software anda GenericRockwell modemtypeshould beselectedinyourVoicesoftware Note that your software must be configured to communicate with t...

Страница 8: ...sofyourmodem This software should be sufficient for all of your communicationneeds Theremaybetimeswhenyou need to access the modem manually via modem com mands ReadSection3forasummarydescriptionofthe...

Страница 9: ...2 Command Structure Allcommandssenttothemodemmustbeginwith AT and end with ENTER All commands may be typed ineitherupperorlowercase butnotmixed Tomakethe command line more readable spaces may be inser...

Страница 10: ...eID I4 ReservedID L_ L0 Lowspeakervolume L1 Low speaker volume L2 Mediumspeakervolume L3 Highspeakervolume M_ M0 Internalspeakeroff M1 Internal speaker on until carrier detected M2 Internalspeakeralwa...

Страница 11: ...rofile1 3 4 Extended AT Commands C_ C0 Force Carrier Detect Signal High ON C1 TurnonCDwhenremotecarrierispresent D_ D0 Modem ignores the DTR signal D1 Modem returns to Command Mode after DTRtoggle D2...

Страница 12: ...Test T7 Perform a Remote Digital Loopback Test andSelf Test T8 PerformLocalAnalogLoopbackTestand Self Test V V DisplaysActiveandStoredProfiles W_ W0 Stores the active profile as Profile 0 W1 Stores th...

Страница 13: ...Returns Caller ID capabilities of modem 3 5 MNP V 42 V 42bis Commands C_ C0 Disable MNP Class 5 and V 42bis data compression C1 Enable MNP Class 5 data compression only C2 EnableV 42bisdatacompressio...

Страница 14: ...eive FCON FacsimileConnectionResponse FCIG Setthepolledstationidentification FCIG Reportthepolledstationidentification FCR CapabilitytoReceive FCR CapabilitytoReceive FCSI Report the Called Station ID...

Страница 15: ...veMode VSDB Silencedeletiontuner VSK Buffer skid setting VSP Silencedetectionperiod VSR Samplingrateselection VSS Silencedeletiontuner VTD DTMFtonereportingcapability VTM Enabletimingmarkplacement VTS...

Страница 16: ...CTS DTR DCD DSR and Bit mapped register Long Space Disconnect S22 Speaker and response Bit mapped register S23 Remote Digital Loopback Bit mapped register Request data rate and parity S24 Sleep mode...

Страница 17: ...75 1200 45 CARRIER 1200 46 CARRIER 2400 47 CARRIER 4800 48 CARRIER 7200 49 CARRIER 9600 50 CARRIER 12000 51 CARRIER 14400 52 CARRIER 21600 55 CARRIER 24000 56 CARRIER 26400 57 CARRIER 28800 64 COMPRE...

Страница 18: ...e Modemandsoftwaremustbe configuredidentically 2 Make sure the phone line is working properly Replace themodemwitharegularphoneanddialthenumber If thelinesoundsnoisy youmayhavedifficultyconnecting tot...

Страница 19: ...Use GenericRockwell orsimi larselection Section Seven Support and Service Intheunlikelyeventyouexperiencedifficultyinthe use of this product we suggest you 1 consult the Troubleshootingsectionofthisgu...

Страница 20: ...hone company If your telephone equipment causes harm to the telephone network the Telephone Company may discontinue your ser vice temporarily If possible they will notify in advance But if advance not...

Страница 21: ...t from that to which the receiver is connected Consultthedealeroranexperiencedradio TVtechnicianfor help Notice 1 Shielded cables if any must be used in order to comply with the emission limits 2 Any...

Страница 22: ...ec tion authority or electrician as appropriate NOTICE The Load Number LN assigned to each terminal devicedenotesthepercentageofthetotalloadtobeconnected to a telephone loop which is used by the devic...

Страница 23: ...21...

Отзывы: