 CLASSIFICATION

Protection against electric shock: . . . . . . . . . . . . . . . . . . . . . . . . . . Internally powered equipment.
Protection against water:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IPX1
Mode of Operation:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Continuous
Flammable anesthetic mixture:. . . . . . . . . . . . . . . . . . . . . . . . Not suitable for use in presence of a  

flammable anesthetic mixture

       

Product Disposal Instructions:

      

The sensor, batteries, and circuit board are not suitable for regular trash  

      disposal. Return sensor to Maxtec for proper disposal or dispose    
      according to local guidelines. Follow local guidelines for disposal of 
      other components.

WARRANTY

The N2 analyzer is designed for oxygen delivery equipment and systems. 
Under normal operating conditions, we warrant the N2 analyzer to be free 
from defects of workmanship or materials for a period of 2- years from the 
date of shipment provided that the unit is properly operated and maintained 
in accordance with our operating instructions. Based on our product 
evaluation our sole obligation under the foregoing warranty is limited to making 
replacements, repairs, or issuing credit for equipment found to be defective. 
This warranty extends only to the buyer purchasing the equipment directly 
from us or through our designated distributors and agents as new equipment. 
Our warrants the oxygen sensor in the N2 analyzer to be free from defects in 
material and workmanship for a period of 2-years from the date of shipment 
in a N2 analyzer. Should a sensor fail prematurely, the replacement sensor is 
warranted for the remainder of the original sensor warranty period. Routine 
maintenance items, such as batteries, are excluded from warranty. We and 
any other subsidiaries shall not be liable to the purchaser or other persons for 
incidental or consequential damages or equipment that has been subject to 
abuse, misuse, mis-application, alteration, negligence or accident.

These warranties are exclusive and in lieu of all other warranties, expressed or 

implied, including warranty of merchantability and fitness for a particular purpose.

         866.4.Maxtec   www.maxtec.com

Содержание Handi+N2

Страница 1: ...E Handi N2 O P E R A T I N G M A N U A L I N S T R U C T I O N S F O R U S E R 2 1 8 M 0 6 I n d u s t r i a l R218M06 Rev E N2...

Страница 2: ......

Страница 3: ...th our operating instructions Based on our product evaluation our sole obligation under the foregoing warranty is limited to making replacements repairs or issuing credit for equipment found to be def...

Страница 4: ...he oxygen sensor is a sealed device containing a mild acid electrolyte lead Pb and lead acetate Lead and lead acetate are hazardous waste constituents and should be disposed of properly or returned fo...

Страница 5: ...DE IV 1 0 INTRODUCTION 1 2 0 N2 ANALYZER FEATURES AND FUNCTIONS 1 3 0 PRE USE CHECKOUT CALIBRATION 2 4 0 OPERATION PRINCIPALS 2 5 0 FACTORS INFLUENCING ACCURATE READINGS 2 6 0 CALIBRATION ERRORS AND E...

Страница 6: ...he Handi Do not throw away Follow local guidelines for disposal Follow instructions for use Do Not On off Button Warnings Calibration Button Meets ETL standards LOT IPX1 Lot code Batch code Drip Proof...

Страница 7: ...2 Analyzer enters its sleep power off mode The N2 Analyzer will automatically enter the sleep mode after 2 minutes from the last time the unit was energized You can manually turn off the analyzer by p...

Страница 8: ...ncing accurate readings 5 The N2 Analyzer is ready to use 4 0 OPERATION PRINCIPALS The instrument display corresponds directly to the oxygen sensor The oxygen diffuses through the membrane and an elec...

Страница 9: ...ng use the same apparatus and flow rates when calibrating as when measuring The N2 analyzer oxygen sensor has been tested at pressures up to two atmospheres absolute Calibration or operation above thi...

Страница 10: ...calibration If unit repeats this error more than three times contact Maxtec Customer Service for possible sensor replacement CAL Err hi Sensor voltage too high Press and hold the Calibration Button fo...

Страница 11: ...or 90 step change at 25 C Warm up Time None required Operating Temperature 15 C 40 C 59 F 104 F Storage Temperature 15 C 50 C 5 F 122 F Operating Pressure Atmospheric pressure to 3psig Environmental G...

Отзывы: