Enrolling the Module

If you will be using the PC4401 as a printer or DataLink
module, you must enroll it with the PC4020.

NOTE:

 If you will be using the PC4401 as a PC-LINK

isolator, DO NOT enroll the PC4401.

1. Enter installer’s programming by pressing [*] [8]

[Installer’s Code].

2. Scroll to “Module Hardware” and press the [*] key. 
3. Scroll to “Enroll Module” and press the [*] key.
4. Scroll through the different modules until “PC44XX

RS-232” is displayed. Press the [*] key.

5. The message “Create Tamper on Desired Unit” will

be displayed. To create the required tamper, secure
the tamper zone on the module and then open it. The
transition from secure to violated enrolls the module.
After this is done, the keypad will display the mod-
ule number and will confirm enrollment (e.g.
“PC44XX Mod 01 Enrolled”).

For more information regarding module enrollment, see
the control panel 

Installation Manual

.

5.

Programming the Module

NOTE: 

If you will be using the PC4401 as a PC-LINK iso-

lator, you will not need to do any programming for it.

To access PC4020 programming, enter [*][8] followed by
the Installer’s code. The sections you will need to pro-
gram are described below. For more information regard-
ing programming, see the control panel 

Installation

Manual

.

The PC4401 module programming sections are located in
the System Area section under the PC44XX options.
Once you have entered installer’s programming, enter
the indicated reference number; OR use the [<] [>] keys
to scroll through the programming options on the LCD
display and press [*] to select the desired option. 
The following explains each programming option rele-
vant to the PC4401.

5.1

Baud Rate

Ref. # [000800XX00], 

where XX = PC4401 module no.

This section is used to program which Baud rate the
PC4401 serial interface module will use to communicate
with a serial printer. The Baud rate is the speed at which

information will be transmitted from the PC4401 module
to the serial printer. There are five different Baud rates
available to the PC4401 module: 300, 600, 1200, 2400 and
4800 Baud. If you are experiencing problems with miss-
ing characters, try lowering the Baud rate.

5.2

Module Function

Ref. # [000800XX00], 

where XX = PC4401 module no.

In this section you must select which function you want
the PC4401 to perform: Printer, DVACS, or DataLink.
To use the PC4401 as a printer module, you must select
the Printer option in this section. Scroll to the message
“Printer”, then press [*].
To use the PC4401 as a DataLink module, you must select
the DataLink option in this section. Scroll to the message
“DataLink”, then press [*].
To use the PC4401 as a PC-LINK isolator module, leave
the programming of this section at the default setting.

NOTE:

 You may only program one function for each

PC4401 module.

5.3

Trouble Conditions

The control panel always watches for possible trouble
conditions. If a trouble condition occurs, the keypad
“Trouble” light will turn on and the keypad will beep.
Press [

][2] to display the trouble conditions.

The following trouble conditions apply to the PC4401
module. For a description of all troubles, please see your
system

  Installation Manual

. Reporting codes for these

troubles can be programmed (ref. # [000403] OR scroll to

System Area

, then 

Communicator

, then 

Reporting

Codes

).

• Printer Off-line
• PC44XX Trouble
• DataLink Off-line
If programmed, the panel can also send reporting codes
for the following conditions:
• General System Tamper Alarm 
• General System Tamper Restore 
Record your reporting code choices in the panel’s 

Pro-

gramming Worksheets

 booklet.

Programming Worksheet

Module Function

Ref # [000800XX00], where XX = PC4401 module number

I_______I

Not used (00)

I_______I

DVACS (02

)

I_______I

Printer (01)

I_______I

DataLink (03)

Baud Rate

Ref # [000800XX01], where XX = PC4401 module number

I_______I

300

I_______I

600

I_______I

1200

I_______I

2400

I_______I

4800

Содержание PC4401

Страница 1: ...DataLink Module Application Guide WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be carefully read ...

Страница 2: ... 3 2 Mounting the Cabinet 1 3 3 Wiring the PC4401 as a Printer or DataLink Module 2 3 4 Wiring the PC4401 as a PC LINK Isolator Module 3 3 5 Applying Power 3 4 Enrolling the Module 4 5 Programming the Module 4 5 1 Baud Rate 4 5 2 Module Function 4 5 3 Trouble Conditions 4 Programming Worksheet 4 ...

Страница 3: ... for more information 2 Specifications Input 12VDC via Combus connection Normal current draw of 35 mA Tamper and Trouble reporting codes PC4401 as a printer or DataLink module Four wire QUAD hook up to Combus Low Combus supervision to main control panel True RS 232 technology Protocol DTR Five possible Baud rates 300 600 1200 2400 or 4800 Maximum cable length 10 feet 3 meters 3 Installing the PC44...

Страница 4: ...our Combus wires to the PC4401 Con nect the red black yellow and green Combus wires to the RED BLK YEL and GRN terminals respec tively 2 Connect terminals T1 and T2 to a normally closed tamper switch If no tamper switch is desired con nect a jumper wire between T1 and T2 terminals 3 Consult Diagram 1 below for more information NOTE DataLink is not a UL nor ULC Listed feature Diagram 1 Connecting t...

Страница 5: ...el to the RED and BLK terminals on the PC4401 2 Consult Diagram 2 below for more information 3 5 Applying Power After all wiring is completed apply power to the control panel Connect the battery leads to the battery then con nect the AC transformer For more information on con trol panel power specifications see the control panel Installation Manual NOTE Do not connect the power until all wiring is...

Страница 6: ...printer The Baud rate is the speed at which information will be transmitted from the PC4401 module to the serial printer There are five different Baud rates available to the PC4401 module 300 600 1200 2400 and 4800 Baud If you are experiencing problems with miss ing characters try lowering the Baud rate 5 2 Module Function Ref 000800XX00 where XX PC4401 module no In this section you must select wh...

Страница 7: ... air conditioners or other appli ances or passing traffic Audible warning devices however loud may not be heard by a hearing impaired person Te l e p h o n e Li n e s If telephone lines are used to transmit alarms they may be out of service or busy for certain periods of time Also an intruder may cut the telephone line or defeat its operation by more sophisticated means which may be difficult to d...

Страница 8: ...nce to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Re orient the receiving antenna Increa...

Отзывы: