4
4.
Enrolling the Module
If you will be using the PC4401 as a printer or DataLink
module, you must enroll it with the PC4020.
NOTE:
If you will be using the PC4401 as a PC-LINK
isolator, DO NOT enroll the PC4401.
1. Enter installer’s programming by pressing [*] [8]
[Installer’s Code].
2. Scroll to “Module Hardware” and press the [*] key.
3. Scroll to “Enroll Module” and press the [*] key.
4. Scroll through the different modules until “PC44XX
RS-232” is displayed. Press the [*] key.
5. The message “Create Tamper on Desired Unit” will
be displayed. To create the required tamper, secure
the tamper zone on the module and then open it. The
transition from secure to violated enrolls the module.
After this is done, the keypad will display the mod-
ule number and will confirm enrollment (e.g.
“PC44XX Mod 01 Enrolled”).
For more information regarding module enrollment, see
the control panel
Installation Manual
.
5.
Programming the Module
NOTE:
If you will be using the PC4401 as a PC-LINK iso-
lator, you will not need to do any programming for it.
To access PC4020 programming, enter [*][8] followed by
the Installer’s code. The sections you will need to pro-
gram are described below. For more information regard-
ing programming, see the control panel
Installation
Manual
.
The PC4401 module programming sections are located in
the System Area section under the PC44XX options.
Once you have entered installer’s programming, enter
the indicated reference number; OR use the [<] [>] keys
to scroll through the programming options on the LCD
display and press [*] to select the desired option.
The following explains each programming option rele-
vant to the PC4401.
5.1
Baud Rate
Ref. # [000800XX00],
where XX = PC4401 module no.
This section is used to program which Baud rate the
PC4401 serial interface module will use to communicate
with a serial printer. The Baud rate is the speed at which
information will be transmitted from the PC4401 module
to the serial printer. There are five different Baud rates
available to the PC4401 module: 300, 600, 1200, 2400 and
4800 Baud. If you are experiencing problems with miss-
ing characters, try lowering the Baud rate.
5.2
Module Function
Ref. # [000800XX00],
where XX = PC4401 module no.
In this section you must select which function you want
the PC4401 to perform: Printer, DVACS, or DataLink.
To use the PC4401 as a printer module, you must select
the Printer option in this section. Scroll to the message
“Printer”, then press [*].
To use the PC4401 as a DataLink module, you must select
the DataLink option in this section. Scroll to the message
“DataLink”, then press [*].
To use the PC4401 as a PC-LINK isolator module, leave
the programming of this section at the default setting.
NOTE:
You may only program one function for each
PC4401 module.
5.3
Trouble Conditions
The control panel always watches for possible trouble
conditions. If a trouble condition occurs, the keypad
“Trouble” light will turn on and the keypad will beep.
Press [
✱
][2] to display the trouble conditions.
The following trouble conditions apply to the PC4401
module. For a description of all troubles, please see your
system
Installation Manual
. Reporting codes for these
troubles can be programmed (ref. # [000403] OR scroll to
System Area
, then
Communicator
, then
Reporting
Codes
).
• Printer Off-line
• PC44XX Trouble
• DataLink Off-line
If programmed, the panel can also send reporting codes
for the following conditions:
• General System Tamper Alarm
• General System Tamper Restore
Record your reporting code choices in the panel’s
Pro-
gramming Worksheets
booklet.
Programming Worksheet
Module Function
Ref # [000800XX00], where XX = PC4401 module number
I_______I
Not used (00)
I_______I
DVACS (02
)
I_______I
Printer (01)
I_______I
DataLink (03)
Baud Rate
Ref # [000800XX01], where XX = PC4401 module number
I_______I
300
I_______I
600
I_______I
1200
I_______I
2400
I_______I
4800