XStream™
OEM
RF
Module
–
Product
Manual
v5.x00
[2006.02.24]
RS-485 (4-wire) & RS-422 Operation
DIP Switch Settings and Serial Port Connections
Figure
B
‐
17
Figure
B
‐
18
RS
‐
485
(4
‐
wire)
and
RS
‐
422
Pins
used
on
the
female
RS
‐
232
(DB
‐
9)
DIP
Switch
Settings
Serial
Connector
©
2006
MaxStream,
Inc.
Confidential
and
Proprietary
60
Figure
B
‐
19
RS
‐
485
(4
‐
wire)
&
RS
‐
422
with
Termination
(o
ptional)
Table
B
‐
07.
RS
‐
485/422
(4
‐
wire)
Signals
and
their
implementations
with
the
Module
Assembly
Termination is the 120
Ω
resistor between T+ and T-.
DIP Switch settings are read and applied only while powering-on.
DB-9 Pin
RS-485/422
Name
Description
Implementation
2 T-
(TA)
Transmit Negative
Serial data sent from the XStream Module Assembly
Data Line
3 R- Receive Negative
Serial data received by the XStream Module Assembly
(RA) Data Line
5 GND Signal
Ground
Ground
7 R+
(RB)
Serial data rec
Assembly
Receive Positive
Data Line
eived by the XStream Module
8 T+
(TB)
Transmit Positive
Serial dat
mbly
Data Line
a sent from the XStream Module Asse
9 PWR Power
Optional power input that is connected internally
to the front power connector
1, 4, 6
not used
Wiring Diagram: RS-485 (4-wire) Half-Duplex
Figure
B
‐
20.
XStream
Module
Assembly
in
an
RS
‐
485
(4
‐
wire)
environment
electronic components distributor