![Maxon IDX 56 Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/maxon/idx-56/idx-56_user-manual_1745158034.webp)
Electrical Installation
Connections
IDX 56 User Manual
4-34
mmag | 2020-04 | rel9398
4.3.5
Supply (X4)
Holding break supply voltage
With the optionally available holding break, the minimal power supply voltage must be at least 24 VDC.
Figure 4-19
Power connector X4
Table 4-25
Power connector X4 – Specification
Table 4-26
Power connector X4 – Pin assignment
For suitable prefab cable assemblies see
Continued on next page.
Power connector X4
Type
M12, male, 5 poles, L-coded
X4
Head A
Prefab
cable
Signal
Description
Pin
Color
1
brown
+V
CC
Power supply voltage (+12…+48 VDC)
2
white
+V
C
Logic supply voltage (+12…+48 VDC)
3
blue
GND
Power ground
4
black
+V
I/O
I/O supply voltage (+20…+30 VDC)
5
gray
FE
Functional earth