LIFT CORPORATION
Sht. 5 of 10 DSG#
M-16-05
Rev.
A
Date: 01/16/17
© MAXON Lift Corp. 2017
CAUTION
Allow welds to cool before attaching plastic enclosure.
4.
Bolt the plastic enclosure (Kit item) to
the angle plate
(FIG. 5-1)
.
LOCK NUT, 1/4”-20
(4 PLACES)
CAP SCREW, 1/4”-20
(4 PLACES)
FLAT WASHER, 1/4”
(8 PLACES)
PLASTIC
ENCLOSURE
BOLTING ENCLOSURE TO ANGLE PLATE
FIG. 5-1
5.
Turn
OFF
the master disconnect switch at the pump
box to disconnect battery power from the hydraulic
pumps. Refer to
BMR Operation Manual
for detailed
instructions.
ANGLE
PLATE
`
To prevent accidental personal injury and equipment damage, make sure power is
disconnected from Liftgate while installing parts.