Motherboard Design Guide
Design Guidelines
maxon motor control
ESCON Servo Controller
Document ID: rel3601
5-29
ESCON Module 50/4 EC-S Hardware Reference
Edition: September 2013
© 2013 maxon motor. Subject to change without prior notice.
5.2
Design Guidelines
The following instructions are intended to serve as an aid for designing an application-specific mother-
board and ensuring the correct and reliable integration of the ESCON Module 50/4 EC-S.
5.2.1
Ground
All ground connections (GND) should be internally connected to the ESCON Module 50/4 EC-S (equal
potential). It is customary to equip the motherboard with a ground plane. All ground connections should
be connected to the voltage supply ground via wide conductive tracks.
Table 5-11
Motherboard Design Guide – Grounding
If an earth potential is in place or required, the ground plane should be connected to the earth potential
via one or more capacitors. The use of ceramic capacitors with 100 nF and 100 V is recommended.
5.2.2
Layout
Guidelines for the layout of the motherboard:
•
Connector pins [7] and [8] +V
CC
operating voltage:
The pins should be connected to the fuse via wide conductive tracks.
•
Connector pins [9], [10] and [23] ground:
All pins should be connected with the ground of the operating voltage via wide conductive
tracks.
•
The width of the conductive track and the copper coating thickness of the conductors for supply
voltage and motor depend on the current required for the application. A minimum width of 75 mil
is recommended for the track and a minimum thickness of 35
μ
m for the copper coating.
5.3
THT Footprint
Figure 5-18
THT Footprint [mm] – View from above
Pin
Signal
Description
9
Power_GND
GND
Ground of operating voltage
Ground
10
Power_GND
GND
Ground of operating voltage
Ground
23
GND
Ground