3.3.16
DIP Switch Configuration (SW1)
Figure 3-44
DIP switch SW1
3.3.16.1
CAN ID (Node Address)
The CAN ID is set with DIP switches 1…5. The node address (1…31) may be coded using binary code.
Setting the CAN ID by DIP switch SW1
• By setting the DIP switch (1…5) address 0 (“OFF”), the CAN ID may be set by software (changing
object “Node ID”, range 1…127).
• The CAN ID results in the summed values of DIP switch addresses 1 (“ON”).
• DIP switches 6…8 do not have any impact on the CAN ID.
Table 3-41
DIP switch SW1 – Binary code values
Continued on next page.
Extension Cards
Slot
Description
Part number
EXT1
EPOS4 EtherCAT Card
available soon
EXT2
—
—
Switch
Binary Code
Valence
Setting
1
2
0
1
(factory setting)
2
2
1
2
3
2
2
4
4
2
3
8
5
2
4
16