background image

maxon motor 

maxon motor control 

1-Q-EC Amplifier DEC 50/5 

 

Order number 230572 

Operating Instructions 

October 2008 Edition 

 
The DEC (

D

igital 

E

C

ontroller) is a 1-quadrant amplifier for controlling electronically commutated (brushless) 

DC motors. 
 

 Digital 

speed 

control 

  Maximum speed: 120 000 rpm (motor with 1 pole pair) 

  Operates as speed control, current control or open loop 

speed control 

  /Brake, direction and /disable input 

  AUX connection: adjustable function  

(+5 V output or input for changing speed) 

  Status indicator with red and green LED 

  Set value input through built-in potentiometer (several 

speed ranges can be selected) or through  
analogue set value input (0 ... +5 V) 

  Maximum current limit adjustable 

  Gain can be adjusted in two stages 

  Adjustable speed ramp 

  Protection against heat overload 

  Blockage protection (current limit for blocked motor) 

  Plug-in terminal clamp 

 
 
 
 
 

Table of Contents 

 
1

 

Safety Instructions ..............................................................................................................................................2

 

2

 

Performance Data ..............................................................................................................................................3

 

3

 

Minimum External Wiring for Different Modes of Operation...............................................................................4

 

4

 

Operating Instructions ........................................................................................................................................6

 

5

 

Inputs and Outputs .............................................................................................................................................8

 

6

 

Switch Functions ..............................................................................................................................................12

 

7

 

Speed Ranges..................................................................................................................................................12

 

8

 

Potentiometer Functions...................................................................................................................................13

 

9

 

Operating Status Display..................................................................................................................................14

 

10

 

Protection .........................................................................................................................................................15

 

11

 

EMC-compliant installation ...............................................................................................................................15

 

12

 

Block Diagram ..................................................................................................................................................16

 

13

 

Dimension Drawing ..........................................................................................................................................16

 

 
 
 
 
 
 
The latest edition of these operating instructions may be found in the internet as a PDF-file under 

www.maxonmotor.com

 category “Service & Downloads”, Order number 230572. 

 

Содержание 1-Q-EC

Страница 1: ...ges can be selected or through analogue set value input 0 5 V Maximum current limit adjustable Gain can be adjusted in two stages Adjustable speed ramp Protection against heat overload Blockage protec...

Страница 2: ...ectly if the control unit breaks down or if the cables break etc it must be ensured that the drive or the complete apparatus is kept in a safe operating mode Repairs Repairs may only be carried out by...

Страница 3: ...Motor connections Motor winding 1 Motor winding 2 Motor winding 3 2 6 Trim potentiometers Speed 1 Speed 2 Ramp Imax gain 2 7 LED indicator Operating indicator green LED Error indicator red LED 2 8 Amb...

Страница 4: ...tor 1 Q EC Amplifier DEC 50 5 Operating Instructions 3 Minimum External Wiring for Different Modes of Operation 3 1 Speed control 4 maxon motor control October 2008 Edition Doc No 544910 06 subject to...

Страница 5: ...maxon motor Operating Instructions 1 Q EC Amplifier DEC 50 5 3 2 Current control and open loop speed control October 2008 Edition Doc No 544910 06 subject to change maxon motor control 5...

Страница 6: ...ntinuous max 5 A acceleration short time max 10 A The required voltage can be calculated as follows Known values Operating torque MB mNm Operating speed nB rpm Nominal motor voltage UN V Motor no load...

Страница 7: ...noises the se lected amplification is too high Switch S2 must be set at ON Digital current control 1 Adjust potentiometer P1 Speed 1 to required speed limit Maximum speed in the 500 25 000 rpm range...

Страница 8: ...speed see chapter 7 Speed Ranges 5 1 2 Disable Disabling or blocking the power stage If the input is not wired or the applied voltage is greater than 2 4 V the amplifier is activated A speed ramp will...

Страница 9: ...the limitations described in chapter 5 1 5 Brake function must be observed or the amplifier may be damaged 5 1 4 Ramp function The ramp function enables the motor speed to have a controlled run up whe...

Страница 10: ...ction 50 50 V Max brake current 30 A Delay time approx 12 ms Brake inactive Input open or input voltage 2 4 V Brake active Set input to Gnd or input voltage 0 8 V The maximum permitted brake speed is...

Страница 11: ...with potentiometer Speed 1 Input open or input voltage 4 0 V Speed setting with potentiometer Speed 2 Set input to Gnd or input voltage 1 0 V 5 1 7 Hall sensor 1 Hall sensor 2 Hall sensor 3 Hall senso...

Страница 12: ...rpm 500 120 000 rpm 125 30 000 rpm 67 15 000 rpm Note Independent of the position of the switches S5 and S6 the maximum speed can with the help of P1 Speed be adjusted only in the range 500 25 000 rp...

Страница 13: ...ion of poten tiometers Set value with in ternal potentiome ter P1 Set value with ex ternal potentiome ter With external set value 0 5 V With 2 different speeds Set value with ex ternal potentiome ter...

Страница 14: ...sensors not connected or incorrectly connected Intermittent Hall sensor supply lines Excessive interference to Hall sensor supply lines Solution change supply line feeds use shielded cable Faulty Hal...

Страница 15: ...esis tive connection Use separate cable Hall sensor cable 30 cm Shielded cable highly recommended Connect shielding on both sides DEC 50 5 side Bottom of housing Motor side Motor housing or with motor...

Страница 16: ...Disable Direction Brake Speed AUX V Hall CC Gnd V 10 50V CC Power Ground Motor winding 1 Motor winding 2 Motor winding 3 7 12V 7A 5V 5V 5V P1 Speed 1 P2 Speed 2 Ramp P3 Imax 7 12V 8 Bit Micro Controll...