![Maxkon RAINBOW 2000 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/maxkon/rainbow-2000/rainbow-2000_installation-and-operating-instructions-manual_1744936007.webp)
1.
P
OWER BUTTON: Turns heater on or off.
2.
UP BUTTON: Increases the temperature and timer level.
3.
DOWN BUTTON: Decreases temperature and timer level.
4.
LEVEL BUTTON: Use to adjust heat levels (L1-L4). Press the Level button
then use the up and down buttons (2 and 3) to increase or decrease the
heating level.
5.
TIMER BUTTON: Use to set the timer from 00 – 24(0-24 hours). Adjust using
buttons 2 & 3 to the number of hours you would like to set.
All remote controls have the same frequency, so it is possible to control several heaters with just one
remote.
With working time limitation function: End users can set up the running procedure within a week(7days)
USER MAINTENANCE:
The heater may be wiped-down with a soft damp cloth. Do not use abrasive detergents to clean the unit. In marine
environments, the unit may be gently sprayed clean with clean water with the POWER TURNED OFF and
completely cool. After cleaning, it is advisable to warm the heater for 10 – 20 minutes to dry the unit and
prevent staining.
The lamp used in the Herschel Rainbow is Ultra long life (10,000 hours). Changing the lamp should only be carried
out by suitably qualified personnel using the instructions available on Herschel’s website.
TROUBLESHOOTING:
E1 Error on Display:
Control unit overheat. Check installation clearances.
Let heater cool for 15 minutes and restart heater.
L1,2,3,4 shows in display, but no heat: Bulb is damaged. Arrange for replacement bulb with local Dealer
RECYCLING
At the end of the electrical products useful life it should not be disposed of with household waste.
Please recycle where facilities exist. Check with your Local Authority or retailer for recycling advice in your
country.
Remote Control Function
Butto
n
Function (Heater On)
Function (Heater
Off)
LED Display on
Heater
1
Turns heater on or off
2
Increase Heat Level or
Timer hours
Turns heater on to
Level 1 (minimum)
L1
3
Decrease Heat Level or
Timer Hours
Turns heater on to
Level 4 (Maximum)
L4
4
Enable Heat Level
adjustment
L [n]
5
Enable Timer
adjustment
00-24
[00]-[24]