47
TEST:
Manually light the fireplace to verify the gas supply
is sufficient.
PROCEDURE:
Turn MANUAL knob to MAN.
Insert small tool and depress the plunger.
Light pilot and hold the plunger for 10 seconds.
Turn knob back to ON.
RESULT:
If the manual light is successful, test the electronics.
Troubleshooting the GV60
Testing the Valve
© 2013, Maxitrol Company
f i r e - p a r t s . c o m
Содержание Mertik GV60
Страница 1: ...Advanced Troubleshooting Mertik Maxitrol GV60 Gas Valve 2013 Maxitrol Company fire parts com...
Страница 2: ...2 GV60 System Features 2013 Maxitrol Company fire parts com...
Страница 6: ...6 GV60 System Features 2013 Maxitrol Company Connections fire parts com...
Страница 12: ...GV60 Control Valve Components 12 2013 Maxitrol Company fire parts com...
Страница 26: ...26 GV60 Receiver Components 2013 Maxitrol Company fire parts com...
Страница 29: ...29 To Wall Switch To Valve Receiver Components Wire Harness Connections 2013 Maxitrol Company fire parts com...
Страница 30: ...30 Watch for bent pins Receiver Components Wire Harness Connections 2013 Maxitrol Company fire parts com...
Страница 41: ...41 GV60 Troubleshooting TEST THE BATTERIES 2013 Maxitrol Company fire parts com...
Страница 43: ...43 GV60 Troubleshooting TEST THE INITIAL RECEIVER OUTPUT 2013 Maxitrol Company fire parts com...