MAESTRO 2-S
INSTALLATION
(continued)
6
Follow the instructions supplied with the antenna
mount and secure the mast to the mount.
9
7
8
Feed the cables through the wall to where the read-out is going to
be located. Attach the wires to the rear of the read-out as shown.
The direction wires must follow in sequence for the direction sensor.
The polarity does not matter for the wind speed or power supply
connections. (Do NOT adjust the nuts that are already on the meter).
Mount the brass read-out directly over the cable feed-thru-hole
to avoid crimping the wire under the lip. We recommend mounting
the read-out on one of our pre-drilled and centered panels. Plug the
power supply into a 110 VAC power outlet.
8 FEET
CHIMNEY
MOUNT
VENT-PIPE
MOUNT
TRIPOD
MOUNT
WALL
MOUNT
EVE
MOUNT
CABLE-HOLE
CABLE-HOLE
CABLES
CABLES
SCREW
WOOD
PANEL
WALL
SCREW
2-CONDUCTOR
CABLE FROM
AC POWER
SUPPY
2-CONDUCTOR
CABLE FROM
WIND-SPEED
SENSOR
2
1 3
4 5
5-CONDUCTOR
CABLE FROM
WIND-DIRECTION
SENSOR
Secure the wire to the building using cable clips (do not use regular
staples). Form a drip loop where the wires enter the hole drilled
through the exterior wall. Caulk the hole when done.
DRIP
LOOP
CAULK
WIRE
CABLE
CLIPS
1.888.610.7664
Fluke
-
Direct
.com