Maximum 058-9365-2 Скачать руководство пользователя страница 9

17

16

model no. 058-9365-2 |  contact us 1-888-670-6682

WARNING!

Potential hazard that could result in serious injury or
loss of life.

• Disconnect the tool from the air supply before changing 

   accessories, servicing, or performing maintenance.

• Only use the tool after replacing or repairing any 

   damaged parts or accessories.

• Use only recommended and properly rated replacement 

   parts. Failure to comply could result in serious injury or 
   loss of life.

DANGER!

Potential hazard that will result in serious injury or
loss of life.

• Keep children away from the work area. 

   Do not allow children to handle power tools.

Storage

If it is necessary to store the tool for an extended period of 

time, apply a 

generous amount of lubrication before storing. The tool should be allowed 

to run for approximately 30 seconds after lubricating, in order

 to ensure 

that the lubrication is uniformly distributed throughout the tool.

• Lubrication: If the Air-powered Hammer/

   Chisel and the compressor are not equipped 
   with an in line lubrication system, place up to 

   six drops of pneumatic tool oil into the air 

   inlet before each work day or after every 
   two hours of continuous use, depending 
   on the characteristics of the workpiece.

• Do not use a worn or damaged chisel or quick-change retention

 spring.

• Disconnect the tool from the air supply when it is not in use

.

• Check the air supply for correct size and type of hose connec

tors. Ensure 

   that there is no additional drain on the air line and no moisture or 
   restriction in the air pipe to avoid loss of power or erratic action.

 

 

General inspection 
free movement

Trigger, spring, 
safety mechanism

None

X

Worn or broken 
parts

X

X

Replace worn or 
broken parts

X

Lubrication

See below

Pneumatic 

X

MAINTENANCE
REQUIRED

DESCRIPTION

TOOLS OR
MATERIALS
REQUIRED

MAXIMUM SERVICE INTERVAL

Each use or
every 2 hrs

Monthly

As
needed

In-depth inspection

CAUTION!

 

Potential hazard that may result in moderate injury or 
damage to equipment.

• The tool should be stored in a clean and dry 

   environment. Failure to comply may result in 
   moderate injury or damage to equipment.

tool oil 

TM

Содержание 058-9365-2

Страница 1: ...INSTRUCTION MANUAL Model no IMPORTANT Please read this manual carefully before using this product and save it for reference 058 9365 2 Air Powered Hammer Chisel...

Страница 2: ...W PARTS LIST WARRANTY 4 5 10 11 14 16 18 20 21 22 TABLE OF CONTENTS NOTE If any parts are missing or damaged or if you have any questions please call our toll free helpline at 1 888 670 6682 SAVE THES...

Страница 3: ...TECHNICAL SPECIFICATIONS This manual contains information that relates to PROTECTING PERSONAL SAFETY and PREVENTING EQUIPMENT PROBLEMS It is very important to read this manual carefully and understand...

Страница 4: ...nsfer tube while the compressor is running Allow the parts to cool down before handling or servicing Keep children away from the compressor at all times WARNING Potential hazard that could result in s...

Страница 5: ...load the tool Allow the tool to operate at its optimum speed for maximum ef ciency Do not use the tool if it is leaking air has missing or damaged parts or if it requires repairs Verify that all screw...

Страница 6: ...for light cutting chipping and scraping General usage description Compatible compressor and air tool GUIDELINES FOR PROPER USAGE AND OPERATION Always ensure the use of appropriately matched air tools...

Страница 7: ...n in power ef ciency and general performance AIR TOOLS Read this instruction manual thoroughly and have tool operators read thoroughly before using the tool Read all safety guidelines see section Safe...

Страница 8: ...hose to the compressor and the other end ofthe air hose 1 to the tool 2 Use plumber s tape to avoid air leakage Fig C Use the chisels speci cally designed for this Air powered Hammer Chisel Failure t...

Страница 9: ...hisel and the compressor are not equipped with an in line lubrication system place up to six drops of pneumatic tool oil into the air inlet before each work day or after every two hours of continuous...

Страница 10: ...ely from exhaust One or more motor vanes are stuck due to material build up Pour pneumatic tool oil into the air inlet 2 Tap motor housing gently with plastic mallet 3 Operate the tool by reversing th...

Страница 11: ...rigger Bolt M4 x 8 Valve stem spring 3 1 1 1 1 1 1 1 2 1 1 1 No Qty 13 14 15 16 17 18 19 20 21 22 Pin O ring 4 x 1 1 O ring 4 x 2 Valve stem seat O ring 14 x 2 Rubber Pin 3 x 20 Hand grip O ring 14 5...

Страница 12: ...amage is caused by repairs made or attempted by others i e persons not authorized by the manufacturer and any such unauthorized repairs or attempted repairs shall void this warranty in its entirety FU...

Страница 13: ...nding any provision herein or entitlement of the purchaser at law in equity or otherwise in no event shall the liability of the retailer or manufacturer under this warranty whether in contract tort pr...