PREPARING THE ANTI-MASKING 
CHANNEL FOR OPERATION 

(Obligatory for proper Anti-masking 
operation!!!) 

 

To enable proper operation of the masking 
detection 

(Anti-masking)

, it is necessary to 

allow the detector to automatically study 
and analyze the environmental conditions 
of its protected area. 
This is an obligatory action that should be 
performed by the installer, ensuring proper 
operation of the Anti-masking channel

!!!

 

 

 

Study procedure to be performed in 
two cases: 

 

1.  Upon connecting the power supply to 

the detector (after about 1 minute, the 
time it takes the detector to stabilize 
when first fed by power supply). 
 

2.  Upon the position of DIP switch No. 1 

(LED indicator) is changed. 

 
 

The study procedure: 

 

Immediately close the detector’s case 

(within 15 seconds maximum). 

 

Keep at least 1 meter away from 

detector's front, until the study 
procedure is complete, about 1 minute. 

  

Содержание CURTAIN-Mini

Страница 1: ...Operating Installation Guide CURTAIN Mini Remote Controlled Outdoor Indoor intrusion detector with curtain field of view MAXIMUM Security 1984 Ltd v www maximum co il...

Страница 2: ...lso be controlled by Remote Control option 90 0 mounting bracket provided Extremely reliable highly immune to false alarms Selectable PIR detection sensitivity Selectable Microwave sensitivity Auto te...

Страница 3: ...on and maximum use of all its benefits please read all parts of this installation and operating manual and follow the step by step instructions INTRODUCTION CURTAIN Mini creates a super narrow protect...

Страница 4: ...tect almost any type of material that blocks masks its near field of view It will also detect transparent objects such as clear glass and plastic bags It will activate an alert even if its lens was sp...

Страница 5: ...and defeated 3 This product as any other may malfunction or become damaged during regular use or a result of vandalism 4 A comprehensive inspection of the product in terms of proper activity and perfo...

Страница 6: ...6 12 APPLICATION 3 10 m 10 m...

Страница 7: ...F VIEW DIAGRAMS 2m 10m 15m Microwave 800 0 Side view PIR AND Microwave PIR PIR PIR P I R P I R P I R P I R 10m 15m Microwave 0 Top view PIR AND Microwave 63 cm 30 Detection range of up to 12 meter is...

Страница 8: ...8 12 DETECTION SENSITIVITY ADJUSTMENT and WIRING...

Страница 9: ...d be performed by the installer ensuring proper operation of the Anti masking channel Study procedure to be performed in two cases 1 Upon connecting the power supply to the detector after about 1 minu...

Страница 10: ...n during the study procedure The Red Green LED indicators blink rapidly for about 60 seconds A break of about 20 seconds Green LED indicator are activated The Red Green LED indicators blink rapidly fo...

Страница 11: ...ndicators will blink simultaneously during those 2 seconds Test procedure for masking detection Anti masking o At a distance of about 10 cm from the front of the detector place a white piece of paper...

Страница 12: ...rance 15V DC 20 mA TAMPER Switch endurance 24V DC 0 1A Warm up time 1 Minute Alarm period 2 Seconds Anti masking relay response time 90 Seconds Max Anti masking relay activation period All time of mas...