![Maximum Controls MAX SUPER ARM 2300 Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/maximum-controls/max-super-arm-2300/max-super-arm-2300_installation-and-owners-manual_1744833054.webp)
52
MAX Super 1300/2300 Arms V1
EXIT PWR
ALARM
POWER /
SOLAR IN
BATTERY
INPUT
OPENING
CLOSING
MOTOR 2
MOTOR 1
ERD
OBD PORT
BLACK BOX
PROGRAMMING
SOLAR MODE
MOTOR
OVER
LOAD
ERD
MOTOR
OVER
LOAD
MIN
MAX
OFF
MAX
SENSE
MAX
SENSE
BATTERY
BACKUP MODE
ERD SENSITIVITY
MOTION CONTROL
OPEN
CLOSING GATE SPEED
MOTOR 2
LIMITS
MAG
LOCK
UL
ENTRAP
STOP
CLOSE
CLOSE
TIMER
MAGLOCK
DELAY
JOG
BATTERY
TEST
BATTERY
INPUT
ERROR
BATTERY
IN USE
POWER
REPLACE
BATTERY
LEAVE
CLOSED
LEAVE
OPEN
OPEN
1 TIME
BATTERY VOLTAGE
E
F
1/2
RESET
ID
PLUG
MODULE
PORT
GATE OPEN
GND
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NC
OPEN / CLS NC
GND
12VDC OUT
GND
GND
GND
GND
GND
JOG CLOSE
JOG OPEN
TAMPER IN
TAMPER NO
GATE DISABLE
KEYPAD/CARD
GND
GND
MAX OPEN
FIRE DEPT
RADIO GND
RADIO SIGNAL
STRIKE
CLOSE COM
COM
STOP
OPEN
CLS ONLY 10K
OPEN / CLS 10K
12VDC OUT
NO
COM
NC
COM
GATE CLOSED
LIMIT 1
GND
LIMIT 2
MOTOR 1
LIMITS
MOTOR 1
MOTOR 2
LIMIT 1
GND
LIMIT 2
LIMIT 1
LIMIT 2
LIMIT 1
LIMIT 2
ID PLUG
ERROR
24VDC OUTPUT
12VDC OUTPUT
GND
GND
GND
LOOP
LOOP PWR
LOOP
CENTER
SAFETY
OFF
SINGLE
OPEN
ON/OFF
BATTERY
CLOSE
DUAL
ON
ANTI-
TAILGATE
PUSH
OPEN
PULL
OPEN
GATE
OFF
1
2
3
4
5
6
7
8
9
10
OFF
1
2
3
4
5
6
MIN
MIN
MAX
MAX
ON
OFF
2.5 sec
1.5 sec
FAULTS
OPERATOR
DSP ARM CONTROLLER
OFF
EXIT LOOP
16
MIN
16
MIN
3
1
14
12
9
7
3
1
14
12
9
7
UL SENSOR 10K
UL SENSOR N.C.
MODE A
MODE B
PROGRAM
MOTOR 1
INPUTS
[
+
]
[
-
]
[
+
]
[
-
]
MOTOR 2
INPUTS
MAXIMUM CONTROLS
DSP ARM CONTROLLER
dsp circuit board overview
Factory Wired
External
Loop
Detector
External Loop
Detectors
Solar Input
See pages 36-38.
Max Cell Hub
Sold Separately
See page 35.
Max
Keypad
Sold Separately
See page 35.
Max
Wiegand
Converter
Sold Separately
See page 35.
Wire directly to
7-PIN terminal
Card Reader
Keypad
Key Switch
Telephone Entry
Emergency OPEN
(Overrides gate
disable switch)
MAX OPEN
(Overrides gate
disable switch)
Dry Contact NO
Dry Contact NO
NO
NO
Radio Signal
Radio Signal
Radio Gnd
12 VDC
OR
24 VDC Radio Power
250 mA Max.
4-Wire
Radio
3-W
ire
Radio
Normal
Opening
Device
Stop
Stop
Close
Open
Tamper NO
Tamper IN
Com
Com
Com
Gate Disable
Com
Gnd
Gnd
Gnd
Gnd
Gnd
Gnd
Gnd
NO
NC
Power
NC
NC
Jog Close
Jog Open
External Alarm
Reset Button
Dry Contact
PRE
SS
to RESET
ID Plug:
REQUIRED.
Maglock
Solenoid Lock
Motion Sensor
Opening
Direction
Security
Camera
3-Button Control Station
Dry Contact
See page 33.
Gate Disable Switch
ON
OFF
Siren
Warning
Light
Power
Power
Existing
Building
Alarm
System
Timer
Normally Closed
Photocells
Closing
Direction
Opening
Direction
Closing
Direction
10K
Sensing
Edges
GAT
E OP
EN
GAT
E CLOS
ED
Gate Status Monitoring Device
Power
ONE entrapment
protection sensor
MUST be installed
or operator will
NOT function.
ON
1
2
3
4
5
6
7
8
5 = Op
timum Sens
.
=
Increa
se Sens
.
=
Decr
ease
Sens
.
DEFLECTOMETER
POW
ER
ON
= Nor
mal Power
OFF= No Power
LED INDICA
TORS
DETE
CT
ON
= De
tect
OFF= No De
tect
2 Hz F
lash=D
elay T
iming
SW
1 SW
2 Freq
uency
ON
ON
= Low
ON
OFF =
Medi
um-Lo
w
OFF
ON
= Medium-High
OFF
OFF =
Hig
h
SW
4 SW
5 Ou
tput B
ON
ON =
Pulse
on
Entry
ON
OFF
= B s
ame
as A
OFF
ON =
Pulse
on Ex
it
OFF
OFF
= Lo
op
Fault
SW
3
ON
= Fa
il Se
cure
OFF =
Fail S
afe
SW6
ON =
2 Sec
ond D
elay
OFF
= No
Delay
SW7
ON =
Norm
al Pres
ence
OFF
= Infi
nite
Pres
ence
SW8
ON =
Sens
itivity
Boos
t
OFF
= No
Sen
sitivit
y Boo
st
Loop
Fault
1 Flas
h = O
pen L
oop
2 Flas
hes
= Sho
rted Loop
3 Flas
hes=25
% cha
nge
of In
ductan
ce
Both
LED’s F
lashin
g=
Curr
ent Lo
op Fa
ult
PWR
LED Flas
hing=
Prev
ious L
oop Fau
lt
EDI
Tel: 480
.968.
6407
DEFLEC
TOM
ETE
R
SEN
S
RES
ET
POWE
R
DET
ECT
ED
I
SEN
S
LMA1800
OPTIONS
1
2
3
4
5
6
7
8
ON
Plug-In Loop
Detectors
In-Ground Loop Connections
Loop Detector Rack
In-Ground Loops
Safety Loops
Wired in series
Center
Loop
Safety
Loop
Safety
Loop
Exit
Loop
See page 28.
See page 28.
See page 32.
See page 32.
See page 32.
See page 32.
See page 21.
See page 20.
See page 29.
See pages 26 & 27.
See pages 29 & 33.
See page 29.
DIP-Switches
See page 30.
MAX
ACTU
ATOR AR
M
+
+
-
-
Power
(located on side of control box)
See page 33.
Jog Gate Open/Close
Entrapment
Protection Devices
SAFETY
CENTER
EXIT
J3
J2
J4
J5
12V Power
Stand-Alone Keypad
less than 200 mA
See page 29.
Maglock Delay MUST
be set for 1.5 sec OR
2.5 sec when
installing a lock.
Operator Motor 2
(Secondary/Bi-Parting gates)
Operator Motor 1
(Single/Primary gate)
NC
OPTIONS
ON
1
2
3
4
5
6
7
8
5 = O
ptim
um S
ens.
= In
creas
e Sens
.
= D
ecrea
se Se
ns.
DEFLEC
TOM
ETER
POWE
R
ON =
Norm
al Po
wer
OFF=
No P
ower
LED
INDIC
ATORS
DETE
CT
ON =
Dete
ct
OFF
= No
Detec
t
2 Hz F
lash=D
elay T
iming
SW1
SW2
Fre
quen
cy
ON
ON =
Low
ON
OFF
= M
ediu
m-Lo
w
OFF
ON =
Med
ium-H
igh
OFF
OFF
= Hig
h
SW4
SW5
Outp
ut B
ON
ON =
Puls
e on E
ntry
ON
OFF
= B
sam
e as A
OFF
ON =
Pulse
on
Exit
OFF
OFF
= Lo
op Fault
SW3
ON =
Fail S
ecure
OFF
= Fa
il Safe
SW6
ON =
2 Sec
ond D
elay
OFF =
No D
elay
SW7
ON =
Norm
al Pre
senc
e
OFF
= In
finite
Presen
ce
SW8
ON =
Sensi
tivity
Boos
t
OFF
= No
Sensi
tivity
Boos
t
Loop
Fault
1 Flas
h = O
pen L
oop
2 Flas
hes=
Short
ed Lo
op
3 Flas
hes=2
5% cha
nge
of In
ductanc
e
Both LE
D’s Fl
ashing
=
Curr
ent Lo
op Fau
lt
PWR
LED F
lashin
g=
Prev
ious L
oop Fa
ult
EDI
Tel: 4
80.96
8.6
407
DEFLEC
TOM
ETE
R
SENS
RES
ET
POWE
R
DET
ECT
EDI
SEN
S
LMA
180
0-LP
1
2
3
4
5
6
7
8
ON
page 39
page 33
page 29
page 29
page 28
page 19
page 33
page 29
page 29
page 29
page 36
pages 21 & 31
page 21
page 21
Some UL
sensor inputs
must be
learned to
“MONITOR”
connected
device
See page 30.
ON
LIN
E
COM
M
LIN
K
CEL
L
LIN
K
POW
ER
MAX
CELL
HUB
WIEGAN
D
CON
VER
TER
77
88
99
00
44
55
66
11
22
33
Содержание MAX SUPER ARM 2300
Страница 2: ......