15
02
Maximum charging current:
To configure total charging
current for solar and utility
chargers.
(Max. charging current =
utility charging c
solar charging current)
Available options in 3KVA model With MPPT:
20A
30A
40A (default)
50A
60A
70A
Available options in 5K model
10A
20A
30A
40A
50A
60A (default)
70A
80A
90A
100A
110A
120A
130A
140A
03
AC input voltage range
Appliances (default)
If selected, the transfer time is within
20ms between battery mode and line
mode
UPS
If selected, the transfer time is within
10ms between battery mode and line
mode
04
Power saving mode
enable/disable
Saving mode disable
(default)
If disabled, no matter connected load
is low or high, the on/off status of
inverter output will not be effected.
Saving mode enable
If enabled, the output of inverter will
be off when connected load is pretty
low or not detected.
05
Battery type
AGM (default)
Flooded
User-Defined
If “User-Defined” is selected, battery
charge voltage and low DC cut-off
voltage can be set up in program 26,
27 and 29.
06
Auto restart when overload
occurs
Restart disable
(default)
Restart enable
07
Auto restart when over
temperature occurs
Restart disable
(default)
Restart enable