9
REGENERATION
The regeneration removes the deposits using the salt tablet solution, which rinses out the absorbed calcium
and magnesium ions into the sewage system.
Regeneration takes place automatically in intelligent mode (default). The user just has to programme the
tested water hardness and the system will calculate its efficiency. The display will also show the amount of
litres available before another regeneration cycle is necessary.
The regeneration process consists of 4 cycles:
Cycles (Abbreviation on display):
1
Backwashing (BW)
2
Brine and slow rinse (BD)
3
Fast rinsing (RR)
4
Refilling (SR)
WATER HARDNESS CAPACITY TABLE
English Degree
French Degree
PPM
DH Degrees
System Efficiency
12,5
18,0
178,6
10
2400L / Regen
13,8
19,8
196,5
11
2182L / Regen
15,0
21,6
214,3
12
2000L / Regen
16,3
23,4
232,2
13
1846L / Regen
17,5
25,2
250,0
14
1714L / Regen
18,8
27,0
267,9
15
1600L / Regen
20,0
28,8
285,8
16
1500L / Regen
The stated capacities were calculated based on standard application and machine conditions. This information
may vary according to external influencing factors (for example: fluctuating water quality).
HOW TO USE THE APPLIANCE
Setting the time
Press the “Settings” button followed by the “regeneration” button to set the current time.
Use the arrow keys to increase and decrease the values. Use the “Settings” button to navigate between
minutes and hours.
It’s important to set the correct time as the appliance will automatically start the regeneration process
at 02:00AM.
Once the correct time is set, press the “Settings” button to confirm.